Approximately 20% of the patients are dissatisfied with their total knee arthroplasty (TKA). Computer technology has been introduced for TKA to provide real time intraoperative information on limb alignment and exact flexion/extension gap measurements. The purpose of this study was to determine if patient satisfaction could be improved with the use of robotic-assisted (RA) technology following primary TKA. A total of 120 consecutive patients undergoing RA-TKA with real time intraoperative alignment and gap balancing information were compared with a prospective cohort of 103 consecutive patients undergoing TKA with manual jig-based instruments during the same time period. There were no differences between groups with age, gender, baseline Knee Society Score (KSS) knee and function scores, follow-up, and ASA scores. TKAs were performed using same technique, implant design, anesthesia, and postoperative treatment protocols. Patient satisfaction survey using KSS and Likert scoring system were obtained at 1-year follow-up. Likert scoring system demonstrated 94% of the patients in the RA group were either very satisfied or satisfied versus 82% in the manual instruments TKA group (p = 0.005). RA-TKA group had better average scores of all five satisfaction questions although not significant. RA-TKA group had a better average overall satisfaction score of 7.1 versus 6.6 in the manual instrument group, p = 0.03. KSS function scores were significantly better at 6 weeks and 1 year postoperatively (p = 0.02, 0.005), and KSS knee scores were significantly better at 1 year postoperatively (p = 0.046). There are multiple reasons for patient dissatisfaction following primary TKA. Using intraoperative computer technology with RA surgery for patients undergoing a primary TKA, a significant improvement in patient satisfaction was demonstrated compared with TKA using conventional manual jig-based instruments. RA surgery provides several advantages in TKA including real time information in millimeters to help obtain balanced gaps, accurate bone cuts, reduced soft tissue injury, and achieve the target alignment which may lead to improved patient satisfaction.
Aims Robotic-assisted total knee arthroplasty (RA-TKA) has been introduced to provide accurate bone cuts and help achieve the target knee alignment, along with symmetric gap balancing. The purpose of this study was to determine if any early clinical benefits could be realized following TKA using robotic-assisted technology. Methods In all, 140 consecutive patients undergoing RA-TKA and 127 consecutive patients undergoing conventional TKA with minimum six-week follow-up were reviewed. Differences in visual analogue scores (VAS) for pain at rest and with activity, postoperative opiate usage, and length of stay (LOS) between the RA-TKA and conventional TKA groups were compared. Results Patients undergoing RA-TKA had lower average VAS pain scores at rest (p = 0.001) and with activity (p = 0.03) at two weeks following the index procedure. At the six-week interval, the RA-TKA group had lower VAS pain scores with rest (p = 0.03) and with activity (p = 0.02), and required 3.2 mg less morphine equivalents per day relative to the conventional group (p < 0.001). At six weeks, a significantly greater number of patients in the RA-TKA group were free of opioid use compared to the conventional TKA group; 70.7% vs 57.0% (p = 0.02). Patients in the RA-TKA group had a shorter LOS; 1.9 days versus 2.3 days (p < 0.001), and also had a greater percentage of patient discharged on postoperative day one; 41.3% vs 20.5% (p < 0.001). Conclusion Patients undergoing RA-TKA had lower pain levels at both rest and with activity, required less opioid medication, and had a shorter LOS.
Aims Robotic-assisted total knee arthroplasty (RA-TKA) has been introduced to provide accurate bone cuts and help achieve the target knee alignment, along with symmetric gap balancing. The purpose of this study was to determine if any early clinical benefits could be realized following TKA using robotic-assisted technology. Methods In all, 140 consecutive patients undergoing RA-TKA and 127 consecutive patients undergoing conventional TKA with minimum six-week follow-up were reviewed. Differences in visual analogue scores (VAS) for pain at rest and with activity, postoperative opiate usage, and length of stay (LOS) between the RA-TKA and conventional TKA groups were compared. Results Patients undergoing RA-TKA had lower average VAS pain scores at rest (p = 0.001) and with activity (p = 0.03) at two weeks following the index procedure. At the six-week interval, the RA-TKA group had lower VAS pain scores with rest (p = 0.03) and with activity (p = 0.02), and required 3.2 mg less morphine equivalents per day relative to the conventional group (p < 0.001). At six weeks, a significantly greater number of patients in the RA-TKA group were free of opioid use compared to the conventional TKA group; 70.7% vs 57.0% (p = 0.02). Patients in the RA-TKA group had a shorter LOS; 1.9 days versus 2.3 days (p < 0.001), and also had a greater percentage of patient discharged on postoperative day one; 41.3% vs 20.5% (p < 0.001). Conclusion Patients undergoing RA-TKA had lower pain levels at both rest and with activity, required less opioid medication, and had a shorter LOS.
Aims:Approximately 20% of patients are dissatisfied with their total knee arthroplasty (TKA). Purpose of this study was to determine if patient satisfaction could be improved following TKA using computer technology to obtain the target alignment and precisely balanced gaps.Patients & Methods:75 consecutive patients undergoing primary robotic-arm assisted TKA (RA-TKA) with real-time intraoperative alignment and gap balancing information were compared with a prospective cohort of 75 consecutive patients undergoing primary TKA with manual jig-based instruments during the same time period. There were no differences between groups with age, gender, BMI, and ASA scores. TKA’s were performed by a single surgeon using same implant design, anesthesia and surgical protocols. Patient satisfaction survey using Knee Society (KSS) and Likert scoring system was obtained at 1-year follow-up.Results:Likert scoring system demonstrated 95% of patients in the computer technology group were either very satisfied or satisfied versus 75% in the manual instruments TKA group (p=0.005) at 1-year follow-up. Second question of the KSS which deals with pain at rest was significantly better in RA-TKA group (p=0.04). Fifth question which deals with recreational activities was also significantly improved in the RA-TKA group, p=0.02. RA-TKA group had a better average overall satisfaction score of 7.1 versus 6.4 in the manual instrument group, p=0.03.Conclusion:Using intraoperative computer technology to achieve the target alignment with flexion/extension gap balancing to within 1mm, a significant improvement in patient satisfaction was demonstrated compared to TKA using conventional manual jig-based instruments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.