The incidence rate of treated end-stage renal disease in the united states is 180 per million and continues to rise at a rate of 7.8% per year. Arteriovenous hemodialysis access (AV access) creation and maintenance are two of the most difficult issues associated with the management of patients on hemodialysis. The 1-year complication rate of a primary prosthetic AV access for hemodialysis ranges from 33% to 99%. Various investigators report on patency and complications of AV access. However, it is rather difficult to compare outcomes because of the wide variety of access materials, configurations, locations, risk factors, and quality of inflow and outflow vessels. Although there have been reporting standards for dialysis access endovascular interventions and for central venous access placement, standards regarding surgical access placement and its revision are lacking. The "Dialysis Outcome Quality Initiative," published by the National Kidney Foundation, provides recommendations for optimal clinical practices aimed at improving dialysis outcome and patient survival. This reporting standards document is not meant to be a "practice guidelines" or "best practices" document. Rather, the purpose of this document is to provide standardized definitions related to AV access procedures and to recommend reporting standards for patency and complications, to be used by surgeons, nephrologists, and interventional radiologists, that will permit meaningful comparisons among AV access procedures. The terms, definitions, and categories featured in this article have been approved by the Committee on Reporting Standards of the Society for Vascular Surgery and the American Association for Vascular Surgery and should be observed in preparing manuscripts on AV accesses for submission to the Journal Of Vascular Surgery.
CDU scan is effective in the identification of the type of endoleak, the delineation of the vessel involved, and the hemodynamic information not available with any other testing method. Endoleaks have a dynamic natural history characterized by a variable onset with changing branch vessel involvement and spectral flow patterns. Periodic long-term endograft surveillance with CDU scanning is necessary for following existing endoleaks and for detecting new ones. Corroboration of these findings in larger multicenter prospective trials will be needed to determine whether CDU scan analysis of endoleaks would be predictive of long-term success in endovascular AAA repair.
Although most of the CDU studies were technically suboptimal, the CDUs reliably identified endoleaks with an excellent sensitivity and a negative predictive value as compared with CT scans.
Injury to the abdominal aorta after blunt trauma occurs much less frequently than injury to the thoracic aorta. Although presentations vary, common themes continue to emerge with each patient. Within a 6-month period, our trauma unit diagnosed and treated two cases of blunt abdominal aortic trauma. Both patients were restrained passengers in motor vehicle crashes with resultant abdominal aortic injuries and demonstrated some of the most common associated injuries. Our two cases bring the number found in the literature to 62 and demonstrate the need for rapid recognition and treatment of this potentially lethal injury. This article is a comprehensive review of the management of abdominal aortic injury from blunt trauma.
To determine the effect of primary closure (PC) versus expanded polytetrafluoroethylene patch graft angioplasty (PGA) on the incidence of recurrent stenosis (> 50% lumen diameter narrowing) after carotid endarterectomy (CEA), 87 patients undergoing 100 consecutive CEA were prospectively randomized into two groups. Methods: Forty-four patients underwent 51 PC, and 43 patients underwent 49 PGA. All patients were evaluated after operation by duplex scanning at 1.5, 12, 24, and 36 months. There were no significant differences in the demographic characteristics or operative indications for CEA between the two patient groups. Complete follow-up was achieved in 86% (75/87) of the patients during the 36-month surveillance period. Results: The perioperative permanent neurologic morbidity in the PC and PGA groups was
A Tyrell vein collar at the venous anastomosis of a forearm AVG resulted in premature graft failure. The use of a Tyrell vein collar may accelerate venous anastomosis intimal hyperplasia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.