The increase of aesthetic demands, together with the successful outcome of current implants, has renewed interest in the search for new materials with enough mechanical properties and better aesthetic qualities than the materials customarily used in implanto-prosthetic rehabilitation. Among these materials, zirconium has been used in different types of implants, including prosthetic abutments. The aim of the present review is to analyse current scientific evidence supporting the use of this material for the above mentioned purposes. We carried out the review of the literature published in the last ten years (2000 through 2010) of in vitro trials of dynamic and static loading of zirconium abutments found in the databases of Medline and Cochrane using the key words zirconium abutment, fracture resistance, fracture strength, cyclic loading. Although we have found a wide variability of values among the different studies, abutments show favourable clinical behaviour for the rehabilitation of single implants in the anterior area. Such variability may be explained by the difficulty to simulate daily mastication under in vitro conditions. The clinical evidence, as found in our study, does not recommend the use of implanto-prosthetic zirconium abutments in the molar area. Key words: Zirconium abutment, zirconium implant abutment, zirconia abutment, fracture resistance, fracture strength, cyclic loading.
Total or partial tissue damage and loss of function in an organ are two of the most serious and costly issues in human health. Initially, these problems were approached through organ and allogenic tissue transplantation, but this option is limited by the scarce availability of donors. In this manner, new bone for restoring or replacing lost and damaged bone tissue is an important health and socioeconomic necessity. Tissue engineering has been used as a strategy during the 21st century for mitigating this need through the development of guided bone regeneration scaffold and composites. In this manner, compared with other traditional methods, bone tissue engineering offers a new and interesting approach to bone repair. The poly-α-hydroxy acids, which include the copolymers of lactic acid and glycolic acid, have been used commonly in the fabrication of these scaffolds. The objective of our article was to review the characteristics and functions of scaffold with biomedical applications, with special interest in scaffold construction using poly(lactic-co-glycolic acid) polymers, in order to update the current methods used for fabrication and to improve the quality of these scaffolds, integrating this information into the context of advancements made in tissue engineering based on these structures. In the future, research into bone regeneration should be oriented toward a fruitful exchange between disciplines involved in tissue engineering, which is coming very close to filling the gaps in our ability to provide implants and restoration of functionality in bone tissue. Overcoming this challenge will provide benefits to a major portion of the population and facilitate substantial improvements to quality of life.
Objectives: Placing implants in the posterior maxillary area has the drawback of working with scarce, poor quality bone in a significant percentage of cases. Numerous advanced surgical techniques have been developed to overcome the difficulties associated with these limitations. Subsequent to reports on the elevation of the maxillary sinus through the lateral approach, there were reports on the use of the crestal approach, which is less aggressive but requires a minimal amount of bone. Furthermore, it is more sensitive to operator technique, as the integrity of the sinus membrane is checked indirectly. The aim of this paper is to review the technical literature on minimally invasive sinus lift and compare the advantages of different techniques with Intralift™, a new technique. Study Design: The present study is a review of techniques used to perform minimally invasive sinus lift published in Cochrane, Embase and Medline over the past ten years and the description of the crestal sinus lift technique based on minimally invasive piezosurgery, with the example of a case report. Results: Only eight articles were found on minimally invasive techniques for sinus lift. The main advantage of this new technique, Intralift, is that it does not require a minimum amount of crestal bone (indeed, the smaller the width of the crestal bone, the better this technique is performed). The possibility of damage to the sinus membrane is minimised by using ultrasound based hydrodynamic pressure to lift it, while applying a very non-aggressive crestal approach. Conclusions: We believe that this technique is an advance in the search for less traumatic and aggressive techniques, which is the hallmark of current surgery. Key words: Sinus lift, surgical technique, minimally invasive surgery, ultrasound surgery.
Objectives: This study was undertaken to characterize the mechanical response of bare (as-received) and single-layer ceramized zirconia abutments with both internal and external connections that have been developed to enhanced aesthetic restorations. Material and Methods: Sixteen zirconia implant abutments (ZiReal Post®, Biomet 3i, USA) with internal and external connections have been analyzed. Half of the specimens were coated with a 0.5mm-thick layer of a low-fusing fluroapatite ceramic. Mechanical tests were carried out under static (constant cross-head speed of 1mm/min until fracture) and dynamic (between 100 and 400N at a frequency of 1Hz) loading conditions. The failure location was identified by electron microscopy. The removal torque of the retaining screws after testing was also evaluated. Results: The average fracture strength was above 300N for all the abutments, regardless of connection geometry and coating. In most of the cases (94%), failure occurred by abutment fracture. No significant differences were observed either in fatigue behavior and removal torque between the different abutment groups. Conclusions: Mechanical behavior of Zireal zirconia abutments is independent of the type of internal/external connection and the presence/absence of ceramic coating. This may be clinically valuable in dental rehabilitation to improve the aesthetic outcome of zirconia-based dental implant systems. Key words:Dental implant, zirconia, ceramic structure, mechanical properties.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.