Cervical transcutaneous spinal cord stimulation (tSCS) efficacy for rehabilitation of upper-limb motor function was suggested to depend on recruitment of Ia afferents. However, selectivity and excitability of motor activation with different electrode configurations remains unclear. In this study, activation of upper-limb motor pools was examined with different cathode and anode configurations during cervical tSCS in 10 able-bodied individuals. Muscle responses were measured from six upper-limb muscles simultaneously. First, post-activation depression was confirmed with tSCS paired pulses (50 ms interval) for each cathode configuration (C6, C7, and T1 vertebral levels), with anode on the anterior neck. Selectivity and excitability of activation of the upper-limb motor pools were examined by comparing the recruitment curves (10-100 mA) of first evoked responses across muscles and cathode configurations. Our results showed that hand muscles were preferentially activated when the cathode was placed over T1 compared to the other vertebral levels, while there was no selectivity for proximal arm muscles. Furthermore, higher stimulation intensities were required to activate distal hand muscles than proximal arm muscles, suggesting different excitability thresholds between muscles. In a separate protocol, responses were compared between anode configurations (anterior neck, shoulders, iliac crests, and back), with one selected cathode configuration. The level of discomfort was also assessed. Largest muscle responses were elicited with the anode configuration over the anterior neck, while there were no differences in the discomfort. Our results therefore inform methodological considerations for electrode configuration to help optimize recruitment of Ia afferents during cervical tSCS.
Cervical transcutaneous spinal cord stimulation (tSCS) has been utilized in applications for improving upper-limb sensory and motor function in patients with spinal cord injury. Although therapeutic effects of continuous cervical tSCS interventions have been reported, neurophysiological mechanisms remain largely unexplored. Specifically, it is not clear whether sub-threshold intensity and 10-min duration continuous cervical tSCS intervention can affect the central nervous system excitability. Therefore, the purpose of this study was to investigate effects of sub-motor-threshold 10-min continuous cervical tSCS applied at rest on the corticospinal and spinal reflex circuit in ten able-bodied individuals. Neurophysiological assessments were conducted to investigate (1) corticospinal excitability via transcranial magnetic stimulation applied on the primary motor cortex to evoke motor-evoked potentials (MEPs) and (2) spinal reflex excitability via single-pulse tSCS applied at the cervical level to evoke posterior root muscle (PRM) reflexes. Measurements were recorded from multiple upper-limb muscles before, during, and after the intervention. Our results showed that low-intensity and short-duration continuous cervical tSCS intervention applied at rest did not significantly affect corticospinal and spinal reflex excitability. The stimulation duration and/or intensity, as well as other stimulating parameters selection, may therefore be critical for inducing neuromodulatory effects during cervical tSCS.
Objective: Cervical transcutaneous spinal cord stimulation (tSCS) is a promising technology that can support motor function recovery of upper-limbs after spinal cord injury. Its efficacy may depend on the ability to recruit sensory afferents and convey excitatory inputs onto motoneurons. Therefore, understanding its physiological mechanisms is critical to accelerate its development towards clinical applications. In this study, we used an anatomically realistic computational model of the cervical spine to compare α-motor, Aα-sensory, and Aβ-sensory fiber activation thresholds and activation sites. Approach: We developed a tridimensional geometry of the cervical body and tSCS electrodes with a cathode centred at the C7 spinous process and an anode placed over the anterior neck. The geometrical model was used to estimate the electric potential distributions along motor and sensory fiber trajectories at the C7 spinal level using a finite element method. We implemented dedicated motor and sensory fiber models to simulate the α-motor and Aα-sensory fibers using 12, 16, and 20 µm diameter fibers, and Aβ-sensory fibers using 6, 9, and 12 µm diameter fibers. We estimated nerve fiber activation thresholds and sites for a 2 ms monophasic stimulating pulse and compared them across the fiber groups. Main results: Our results showed lower activation thresholds of Aα- and Aβ-sensory fibers compared with α-motor fibers, suggesting preferential sensory fiber activation. We also found no differences between activation thresholds of Aα-sensory and large Aβ-sensory fibers, implying they were co-activated. The activation sites were located at the dorsal and ventral root levels. Significance: Using a realistic computational model, we demonstrated preferential activation of dorsal root Aα- and Aβ-sensory fibers compared with ventral root α-motor fibers during cervical tSCS. These findings suggest high proprioceptive and cutaneous contributions to neural activations during cervical tSCS, which inform the underlying mechanisms of upper-limb functional motor recovery.
Objective: Cervical transcutaneous spinal cord stimulation (tSCS) is a promising technology that can support motor function recovery of upper-limbs after spinal cord injury. Its efficacy may depend on the ability to recruit sensory afferents, conveying excitatory inputs onto motoneurons. Therefore, understanding its physiological mechanisms is critical to accelerate its development towards clinical applications. In this study, we used an anatomically realistic cervical tSCS computational model to compare α-motor, Aα-sensory, and Aβ-sensory fiber activation thresholds and activation sites. Approach: We developed a 3D geometry of the cervical body and tSCS electrodes with a cathode centred at the C7 spinous process and an anode placed over the anterior neck. The geometrical model was used to estimate the electric potential distributions along motor and sensory fiber trajectories at the C7 spinal level using a finite element method. We implemented dedicated motor and sensory fiber models to simulate the α-motor and Aα-sensory fibers using 12, 16, and 20 µm diameter fibers, and Aβ-sensory fibers using 6, 9, and 12 µm diameter fibers. We estimated nerve fiber activation thresholds and sites for a 2 ms monophasic stimulating pulse and compared them across the fiber groups. Main results: Our results showed lower activation thresholds of Aα- and Aβ-sensory fibers compared with α-motor fibers, suggesting preferential sensory fiber activation. We also found no differences between activation thresholds of Aα-sensory and large Aβ-sensory fibers, implying their co-activation. The activation sites were located at the dorsal and ventral root levels. Significance: Using a realistic computational model, we demonstrated preferential activation of dorsal root Aα- and Aβ-sensory fibers compared with ventral root α-motor fibers during cervical tSCS. These findings suggest high proprioceptive and cutaneous contributions to neural activations during cervical tSCS, which inform the underlying mechanisms of upper-limb functional motor recovery.
Background Cervical transcutaneous spinal cord stimulation (tSCS) is a rehabilitation tool which has been used to promote upper‐limb motor recovery after spinal cord injury. Importantly, optimizing sensory fiber activation at specific spinal segments could enable activity‐dependent neuromodulation during rehabilitation. Methods An anatomically realistic cervical tSCS computational model was used to analyze the activation of α‐motor and Aα‐sensory fibers at C7 and C8 spinal segments using nine cathode electrode configurations. Specifically, the cathode was simulated at three vertebral level positions: C6, C7, and T1; and in three sizes: 5.0 × 5.0, 3.5 × 3.5, and 2.5 × 2.5 cm2, while the anode was on the anterior neck. Finite element method was used to estimate the electric potential distribution along α‐motor and Aα‐sensory fibers, and computational models were applied to simulate the fiber membrane dynamics during tSCS. The minimum stimulation intensity necessary to activate the fibers (activation threshold) was estimated and compared across cathode configurations in an effort to optimize sensory fiber activation. Results Our results showed that nerve fibers at both C7 and C8 spinal segments were recruited at lower stimulation intensities when the cathode was positioned over the C7 or T1 vertebra compared with the C6 position. Sensory fibers were activated at lower stimulation intensities using smaller electrodes, which could also affect the degree of nerve fiber activation across different positions. Importantly, Aα‐sensory fibers were consistently recruited before α‐motor fibers. Conclusions These results imply that cathode positioning could help optimize preferential activation of hand muscles during cervical tSCS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.