Despite aortic stenosis (AS) relief, patients undergoing transcatheter aortic valve implantation (TAVI) are at increased risk of developing heart failure (HF) within first months of intervention. Sodium-glucose co-transporter 2 (SGLT-2) inhibitors have been shown to reduce the risk of HF hospitalization in individuals with diabetes mellitus, reduced left ventricular ejection fraction and chronic kidney disease. However, the effect of SGLT-2 inhibitors on outcomes after TAVI is unknown. The Dapagliflozin after Transcatheter Aortic Valve Implantation (DapaTAVI) trial is designed to assess the clinical benefit and safety of the SGLT-2 inhibitor dapagliflozin in patients undergoing TAVI.
Background While transcatheter aortic valve implantation (TAVI) is established for treating highoperative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (≤20 mm). Objectives In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. Results Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and minimum annular diameters were 19±1 and 17±2 mm, respectively, in native patients with AS, and 17±1 mm (internal diameter) in V-in-V recipients. Successful device implantation rate was 96%, with no procedural-related death. Overall in-hospital-30-day death, stroke and major bleeding rates were 5%, 2% and 9%, respectively. In native AS TAVI recipients, mean transaortic gradient decreased from 54±20 to 12±5 mm Hg ( p<0.001), and from 45±17 to 24±8 mm Hg ( p<0.001) in V-in-V recipients. Severe prosthesis-patient mismatch (PPM) rates were 10% and 48% in native AS and V-in-V TAVI recipients, respectively ( p=0.03). Post-TAVI, the rate of moderate aortic regurgitation was 7% and 0% in native AS and V-in-V TAVI recipients, respectively. Conclusions TAVI with the 20 mm SAPIEN XT THV appears safe and technically feasible, with acceptable short-term clinical outcomes and low rates of severe PPM in those with native AS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.