BACKGROUNDThe presence of a cardiovascular implantable electronic device has long been a contraindication for the performance of magnetic resonance imaging (MRI). We established a prospective registry to determine the risks associated with MRI at a magnetic field strength of 1.5 tesla for patients who had a pacemaker or implantable cardioverterdefibrillator (ICD) that was "non-MRI-conditional" (i.e., not approved by the Food and Drug Administration for MRI scanning). METHODSPatients in the registry were referred for clinically indicated nonthoracic MRI at a field strength of 1.5 tesla. Devices were interrogated before and after MRI with the use of a standardized protocol and were appropriately reprogrammed before the scanning. The primary end points were death, generator or lead failure, induced arrhythmia, loss of capture, or electrical reset during the scanning. The secondary end points were changes in device settings. RESULTSMRI was performed in 1000 cases in which patients had a pacemaker and in 500 cases in which patients had an ICD. No deaths, lead failures, losses of capture, or ventricular arrhythmias occurred during MRI. One ICD generator could not be interrogated after MRI and required immediate replacement; the device had not been appropriately programmed per protocol before the MRI. We observed six cases of self-terminating atrial fibrillation or flutter and six cases of partial electrical reset. Changes in lead impedance, pacing threshold, battery voltage, and P-wave and R-wave amplitude exceeded prespecified thresholds in a small number of cases. Repeat MRI was not associated with an increase in adverse events. CONCLUSIONSIn this study, device or lead failure did not occur in any patient with a non-MRIconditional pacemaker or ICD who underwent clinically indicated nonthoracic MRI at 1.5 tesla, was appropriately screened, and had the device reprogrammed in accordance with the prespecified protocol. (Funded by St. Jude Medical and others; MagnaSafe ClinicalTrials.gov number, NCT00907361.)
Background-MRI can identify patients with obstructive coronary artery disease by imaging the left ventricular myocardium during a first-pass contrast bolus in the presence and absence of pharmacologically induced myocardial hyperemia. The purpose of this multicenter dose-ranging study was to determine the minimally efficacious dose of gadopentetate dimeglumine injection (Magnevist Injection; Berlex Laboratories) for detecting obstructive coronary artery disease. Method and Results-A total of 99 patients scheduled for coronary artery catheterization as part of their clinical evaluation were enrolled in this study. Patients were randomized to 1 of 3 doses of gadopentate dimeglumine: 0.05, 0.10, or 0.15 mmol/kg. First-pass perfusion imaging was performed during hyperemia (induced by a 4-minute infusion of adenosine at a rate of 140 g · kg Ϫ1 · min Ϫ1 ) and then again in the absence of adenosine with otherwise identical imaging parameters and the same contrast dose. Perfusion defects were evaluated subjectively by 4 blinded reviewers. Receiver-operating curve analysis showed that the areas under the receiver-operating curve were 0.90, 0.72, and 0.83 for the low-, medium-, and high-contrast doses, respectively, compared with quantitative coronary angiography (diameter stenosis Ն70%). For the low-dose group, mean sensitivity was 93Ϯ0%, mean specificity was 75Ϯ7%, and mean accuracy was 85Ϯ3%. Conclusions-First-pass
Pulmonary arterial hypertension (PAH) is a progressive disorder characterized by abnormally elevated blood pressure of the pulmonary circulation that results, over time, from extensive vascular remodeling and increased pulmonary vascular resistance. Recent advances in magnetic resonance imaging (MRI) technology have led to the development of techniques for noninvasive assessment of cardiovascular structure and function, including hemodynamic parameters in the pulmonary circulation, which are superior in their identification of right ventricular morphologic changes. These advantages make cardiac MRI an attractive modality for following up and providing prognoses in patients with PAH. In this review, we summarize recent developments in the use of MRI for the diagnosis, assessment, and ongoing monitoring of patients with PAH. Over the coming decade, it can be anticipated that continued improvements in MRI image acquisition, spatial and temporal resolution, and analytical techniques will result in improved understanding of PAH pathophysiology, diagnosis, and prognostic variables, and will supplement, and may even replace, some of the invasive procedures currently applied routinely to the evaluation of PAH.
Background: Cardiovascular magnetic resonance (CMR) has excellent capabilities to assess ventricular systolic function. Current clinical scenarios warrant routine evaluation of ventricular diastolic function for complete evaluation, especially in congestive heart failure patients. To our knowledge, no systematic assessment of diastolic function over a range of lusitropy has been performed using CMR.
Left ventricular function in volume overload hypertrophy is controversial. In humans, chronic severe volume overload eventually results in left ventricular dysfunction; paradoxically, experimental volume overload hypertrophy has nearly always been associated with normal left ventricular function. However, in most cases, experimental volume overload hypertrophy has either been mild or only present for a short duration. To help resolve the issue of contractile function in volume overload hypertrophy, we examined ventricular function in a recently described model of severe chronic experimental mitral regurgitation. Left ventricular function was measured before and 3 mo after the creation of severe mitral regurgitation (averaged regurgitant fraction 0.64 +/- 0.04). At 3 mo end-diastolic volume had increased from 78 +/- 5 to 114 +/- 7 ml (P less than 0.01). Significant left ventricular hypertrophy had occurred with an increase in the left ventricular weight-to-body weight ratio from 3.84 +/- 0.2 to 5.22 +/- 0.2 (P less than 0.01). All indicators of left ventricular function (ejection fraction, the end ejection stress-volume relationship, this relationship corrected for eccentric hypertrophy, and mean velocity of circumferential fiber shortening at a common stress) were reduced at 3 mo. Our study produced 64% volume overload which was maintained for 3 mo at which time there was a 36% increase in left ventricular mass. This amount of volume overload of this duration produced significant left ventricular dysfunction.
Rupture risk assessment of abdominal aortic aneurysms (AAA) by means of biomechanical analysis is a viable alternative to the traditional clinical practice of using a critical diameter for recommending elective repair. However, an accurate prediction of biomechanical parameters, such as mechanical stress, strain, and shear stress, is possible if the AAA models and boundary conditions are truly patient specific. In this work, we present a complete fluid-structure interaction (FSI) framework for patient-specific AAA passive mechanics assessment that utilizes individualized inflow and outflow boundary conditions. The purpose of the study is two-fold: (1) to develop a novel semiautomated methodology that derives velocity components from phase-contrast magnetic resonance images (PC-MRI) in the infrarenal aorta and successfully apply it as an inflow boundary condition for a patient-specific fully coupled FSI analysis and (2) to apply a one-way-coupled FSI analysis and test its efficiency compared to transient computational solid stress and fully coupled FSI analyses for the estimation of AAA biomechanical parameters. For a fully coupled FSI simulation, our results indicate that an inlet velocity profile modeled with three patient-specific velocity components and a velocity profile modeled with only the axial velocity component yield nearly identical maximum principal stress (σ1), maximum principal strain (ε1), and wall shear stress (WSS) distributions. An inlet Womersley velocity profile leads to a 5% difference in peak σ1, 3% in peak ε1, and 14% in peak WSS compared to the three-component inlet velocity profile in the fully coupled FSI analysis. The peak wall stress and strain were found to be in phase with the systolic inlet flow rate, therefore indicating the necessity to capture the patient-specific hemodynamics by means of FSI modeling. The proposed one-way-coupled FSI approach showed potential for reasonably accurate biomechanical assessment with less computational effort, leading to differences in peak σ1, ε1, and WSS of 14%, 4%, and 18%, respectively, compared to the axial component inlet velocity profile in the fully coupled FSI analysis. The transient computational solid stress approach yielded significantly higher differences in these parameters and is not recommended for accurate assessment of AAA wall passive mechanics. This work demonstrates the influence of the flow dynamics resulting from patient-specific inflow boundary conditions on AAA biomechanical assessment and describes methods to evaluate it through fully coupled and one-way-coupled fluid-structure interaction analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.