ObjectivesThe purpose of this study was to review the imaging features of idiopathic granulomatous mastitis (IGM) with clinical and pathology correlation.MethodsWith institutional review board (IRB) approval, a retrospective search of the surgical pathology database from January 2000 to July 2015 was performed. Clinical, imaging and histology findings were reviewed. Cases of granulomatous mastitis without a known source, diagnosed with percutaneous or surgical biopsy, were included in our analysis.ResultsSeventeen cases of IGM were identified with imaging available for review. The majority of patients presented with a palpable abnormality, whereas a minority were asymptomatic with an abnormal screening mammogram. At imaging, IGM most often demonstrated a focal asymmetry at mammography, a hypoechoic mass with irregular or angular margins at ultrasound, and robust enhancement with mixed progressive and plateau kinetics at magnetic resonance imaging (MRI). Axillary lymph nodes were reactive in appearance at ultrasound. Molecular breast imaging performed in one case showed mild focal asymmetric radiotracer uptake.ConclusionIGM is a rapidly progressive rare inflammatory condition of the breast resulting in non-necrotizing granuloma formation. Imaging features mimic breast carcinoma and diagnosis can be difficult. Radiologists’ awareness of this condition is essential to prevent delayed or unnecessary treatment.Teaching points• Idiopathic granulomatous mastitis is rapidly progressive inflammatory condition.• Imaging features may mimic breast carcinoma or infection.• Ultrasound shows irregular hypoechoic masses with increased vascularity and sinus tracts.• MRI shows irregular, enhancing masses or non-mass enhancement with microabscesses.• MRI is useful for assessment of breast involvement and response to treatment.
Rhythmic behaviors are a fundamental feature of all organisms. Pharyngeal pumping, the defecation cycle, and gonadal-sheath-cell contractions are three well-characterized rhythmic behaviors in the nematode C. elegans. The periodicities of the rhythms range from subsecond (pharynx) to seconds (gonadal sheath) to minutes (defecation). However, the molecular mechanisms underlying these rhythmic behaviors are not well understood. Here, we show that the C. elegans Rho/Rac-family guanine nucleotide exchange factor, VAV-1, which is homologous to the mammalian Vav proto-oncogene, has a crucial role in all three behaviors. vav-1 mutants die as larvae because VAV-1 function is required in the pharynx for synchronous contraction of the musculature. In addition, ovulation and the defecation cycle are abnormal and arrhythmic. We show that Rho/Rac-family GTPases and the signaling molecule inositol triphosphate (IP(3)) act downstream of VAV-1 signaling and that the VAV-1 pathway modulates rhythmic behaviors by dynamically regulating the concentration of intracellular Ca(2+).
ADH on core biopsy with low risk of upgrade to cancer is defined by lack of individual cell necrosis, number of foci of ADH, and percent of imaging lesion removed. If these findings are validated, women whose biopsies meet low-risk criteria might be considered for prevention therapy and surveillance without surgical excision.
PurposeThe purpose of our study is to correlate quantitatively measured tumor stiffness with immunohistochemical (IHC) subtypes of breast cancer. Additionally, the influence of prognostic histologic features (cancer grade, size, lymph node status, and histological type and grade) to the tumor elasticity and IHC profile relationship will be investigated.MethodsUnder an institutional review board (IRB) approved protocol, B-mode ultrasound (US) and comb-push ultrasound shear elastography (CUSE) were performed on 157 female patients with suspicious breast lesions. Out of 157 patients 83 breast cancer patients confirmed by pathology were included in this study. The association between CUSE mean stiffness values and the aforementioned prognostic features of the breast cancer tumors were investigated.ResultsOur results demonstrate that the most statistically significant difference (p = 0.0074) with mean elasticity is tumor size. When considering large tumors (size ≥ 8mm), thus minimizing the statistical significance of tumor size, a significant difference (p< 0.05) with mean elasticity is obtained between luminal A of histological grade I and luminal B (Ki-67 > 20%) subtypes.ConclusionTumor size is an independent factor influencing mean elasticity. The Ki-67 proliferation index and histological grade were dependent factors influencing mean elasticity for the differentiation between luminal subtypes. Future studies on a larger group of patients may broaden the clinical significance of these findings.
ObjectivesThis article reviews our experience and describes the literature findings of granulomatous diseases of the breast and axilla.MethodsAfter approval of the Institutional Review Board was obtained, the surgical pathological records from January 2000 to January 2017 were searched for the keyword granulomatous. Clinical, imaging and histology findings were reviewed by both a fellowship-trained radiologist and a breast-imaging consultant radiologist, reviewing 127 patients (age range, 32–86 years; 126 women and 1 man).ResultsMost common causes of granulomatous lesions of the breast and axilla included silicone granulomas 33% (n = 42), fat necrosis 29% (n = 37) and suture granulomas 11% (n = 14). In 16% (n = 20), no cause could be found and clinical history was consistent with idiopathic granulomatous mastitis. Other granulomatous aetiologies included granulomatous infections, sarcoidosis and Sjögren’s syndrome. Causes of axillary granulomatous disease were similar to the breast; however, a case of cat-scratch disease was found that only involved the axillary lymph nodes. They can have a variable appearance on imaging and may mimic malignancy with irregular masses seen on mammography, ultrasound and magnetic resonance imaging. Fistulas to the skin and nipple retraction can suggest chronicity and a granulomatous aetiology. Combination of clinical history, laboratory and imaging findings can be diagnostic.ConclusionsGranulomatous processes of the breast are rare. The diagnosis can, however, be made if there is relevant history (prior trauma, silicone breast implants, lactation), laboratory (systemic or infectious processes) and imaging findings (fistula, nipple retraction). Recognising these entities is important for establishing pathological concordance after biopsy and for preventing unnecessary treatment.Teaching points Breast granulomatous are rare but can mimic breast carcinoma on imaging Imaging with clinical and laboratory findings can correctly diagnosis specific granulomatous breast diseases Recognition of the imaging findings allows appropriate pathological concordance and treatment
Nephrometry scoring with minimal initial instruction was robust across specialties and levels of training. The additional anatomical information that nephrometry score adds to size alone may be associated with other important clinical outcomes such as tumor aggressiveness and survival, and warrants further study.
A growing body of evidence indicates that there is a strong correlation between microvascular morphological features and malignant tumors. Therefore, quantification of these features might allow more accurate differentiation of benign and malignant tumors. The main objective of this research project is to improve the quantification of microvascular networks depicted in contrast-free ultrasound microvessel images. To achieve this goal, a new series of quantitative microvessel morphological parameters are introduced for differentiation of breast masses using contrast-free ultrasound-based high-definition microvessel imaging (HDMI). Using HDMI, we quantified and analyzed four new parameters: 1) microvessel fractal dimension (mvFD), a marker of tumor microvascular complexity, 2) Murray's deviation (MD), the diameter mismatch, defined as the deviation from Murray's law, 3) Bifurcation angle (BA), abnormally decreased angle, and 4) spatial vascular pattern (SVP), indicating tumor vascular distribution pattern, either intratumoral or peritumoral. The new biomarkers have been tested on 60 patients with breast masses. Validation of the feature's extraction algorithm was performed using a synthetic data set. All the proposed parameters had the power to discriminate the breast lesion malignancy (p < 0.05), displaying BA as the most sensitive test, with a sensitivity of 90.6%, and mvFD as the most specific test, with a specificity of 92%. The results of all four new biomarkers showed an AUC=0.889, sensitivity of 80% and specificity of 91.4% In conclusion, the added value of the proposed quantitative morphological parameters, as new biomarkers of angiogenesis within breast masses, paves the way for more accurate breast cancer detection with higher specificity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.