We report a significant complication after tracheocutaneous fistula (TCF) excision with closure by secondary intention in a 4-year-old boy who had been tracheostomy dependent since infancy. He had a persistent 3 mm TCF one year after decannulation. On postoperative day 2 the patient developed profound subcutaneous emphysema and pneumomediastinum. He was extubated after 2 days and discharged from the hospital on postoperative day 7. At follow up he had complete resolution of subcutaneous emphysema and complete closure of the TCF. The main methods of TCF closure and management of subcutaneous emphysema are discussed along with the lessons learned from this case.
Objective: An at home-test for differentiating between conductive and sensorineural hearing loss remains elusive. Our goal was to validate the novel cell-phone vibration test (CPVT) against the Weber tuning fork test (WTFT) and to assess if the CPVT can be self-administered by patients reliably.Study design: Cross-sectional.
Methods:The CPVT involves placement of a vibrating cellphone on the center of the forehead to determine which ear perceives the sound louder. 40 consecutive adult patients with an audiogram within 6 months and no report of recent hearing changes were recruited. Group 1 consisted of 20 patients who were examined by the provider with the CPVT and WTFT using various tuning forks (256, 512, and 1024 Hz). Group 2 consisted of an additional 20 patients who received instructions on selfadministering the CPVT. Kappa statistics were calculated to assess the strength of concordance between the CPVT, WTFT, and audiometric findings for group 1 and between patient self-administered and provider administered CPVT and WTFT for group 2.Results: Concordance between CPVT and WTFT in the entire cohort was substantial (Kappa coefficient: 0.81 for 256 Hz, 0.73 for 512 Hz, and 0.62 for 1024 Hz) with similar concordances between actual and expected results based on audiogram (Kappa coefficient: 0.52 for CPVT and 0.52 for WTFT). Concordance between patient-administered and provider-administered CPVT showed almost perfect agreement (Kappa coefficient: 0.92).
Conclusions:The CPVT provides consistent results when compared to a formal WTFT and can be reliably self-administered by patients with appropriate instructions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.