OBJECTIVETo describe and test a practical protocol to measure common carotid intima-media thickness that uses the combined values of two longitudinal examination angles to increase sensitivity.METHODBetween February and September 2005, 206 patients underwent duplex scan examination of carotid vessels, and the intima-media thickness of 407 common carotids were measured in three angles: transversal, longitudinal posterolateral, and anterolateral, with three intima-media thickness measurements for each near and far wall. In addition to numbers obtained from the three angles of measurement, a fourth visual perspective was obtained by combining the intima-media thickness results of posterolateral and anterolateral longitudinal views and considering the thickest wall measurement.RESULTSTwo hundred seventy (66.3%) carotid arteries had an intima-media thickness thicker than 1mm. The mean intima-media thickness values achieved by the different incidences were 1.26±0.6mm (transversal), 1.17±0.54mm (longitudinal anterolateral), and 1.18±0.58mm (longitudinal posterolateral). A significant difference in intima-media thickness measurement values was observed when the three angles of examination plus the combined positive results of both longitudinal angles were compared by ANOVA (P=0.005). The LSD Post-Hoc test determined that the combined longitudinal view results were similar to the transversal views (P=0.28) and had greater intima-media thickness means than isolated anterolateral or posterolateral longitudinal views (P=0.02 and 0.05, respectively).CONCLUSIONSThe protocol presented is a practical method for obtaining common carotid artery intima-media thickness measurements. The combined longitudinal posterolateral and anterolateral longitudinal views provide a more sensitive evaluation of the inner layers of the carotid walls than isolated longitudinal views.
Objectives To compare the effectiveness of two foam sclerotherapy techniques of the great saphenous vein. Methods Fifty subjects with varicose veins, edema, and great saphenous vein incompetence (diameter 6–10 mm) were randomly categorized into two equal groups and were treated with different foam sclerotherapy techniques: A (usual ultrasound-guided) and B (catheter-directed with tumescence). Concomitant phlebectomy was performed in all patients. Patients were seen on days 7 and 28, and at six and 12 months. The primary outcomes were the full success rate of the treated great saphenous vein and the number of patients who required retreatment sessions performed at 28-day follow-up. The secondary-assisted outcomes were the full success rates of the treated great saphenous vein after the retreatment sessions at six- and 12-month follow-up. Secondary outcomes were changes in quality of life and side effects and complications of the intervention. In case of reflux, retreatment sessions were performed at 28 days and six months in both groups. Results Full success rate of the treated great saphenous vein was 36% in group A vs. 80% in group B ( p = 0.012) and the number of patients who required retreatment sessions were n = 14 in group A vs. n = 3 in group B at 28-day follow-up ( p = 0.002). Both were statistically significant. At six and 12 months, the success rates were not statistically significant between the groups. Complication rates were similar between the groups. Quality of life improved in both groups with statistical difference ( p < 0.001). Conclusions Catheter-directed foam sclerotherapy with tumescence was better than usual ultrasound-guided foam sclerotherapy as it reached higher full success rate of the treated great saphenous vein and as a lower number of patients required retreatment sessions in the short-term. Both methods proved to be safe and improved the quality of life.
We developed an experimental dog model of endovascular lethal injury of the JHIVC with significant increase in abdominal pressures, and a mortality rate of 100%. The treatment of this lesion with SG resulted in a thickened neointima layer, and a 27% reduction in the JHIVC lumen diameter, without clinical repercussion, and with a 100% survival rate.
Objectives To investigate whether radiofrequency endovenous ablation (RFA) of saphenous and perforating veins increases venous leg ulcer (VLU) healing rates and prevents ulcer recurrence. Method This prospective, open-label, randomized, controlled, single-center trial recruited 56 patients with VLU divided into: compression alone (CR, N = 29) and RFA plus compression (RF, N = 27). Primary endpoints were ulcer recurrence rate at 12 months; and ulcer healing rates at 6, 12, and 24 weeks. Secondary endpoints were ulcer healing velocity; and Venous Clinical Severity Score (VCSS). Results Recurrence was lower in the RF group (p < .001), as well as mean VCSS after treatment (p = .001). There were no significant between-group differences in healing rates. Healing velocity was faster in the RF group (p = 0.049). In the RF group, 2 participants had type 1 endovenous heat-induced thrombosis (EHIT). Conclusions RFA plus compression is an excellent treatment for VLU because of its safety, effectiveness, and impact on ulcer recurrence reduction and clinical outcome. Registration: Clinicaltrials.gov, NCT03293836, clinicaltrials.gov.
A anastomose portossistêmica intra-hepática transjugular (TIPS) é um procedimento intervencionista minimamente invasivo realizado pela introdução de prótese metálica auto-expansível no parênquima hepático, via transjugular. Tem por objetivo tratar as complicações da hipertensão portal, principalmente a hemorragia digestiva alta e a ascite refratária. A estenose é complicação freqüente, embora o procedimento seja eficaz e com baixo índice de insucesso. O diagnóstico precoce da estenose é de fundamental importância, pois interfere no tipo de tratamento a ser realizado e o reaparecimento dos sintomas pode ser grave. O ultra-som Doppler é então utilizado para o seguimento dos pacientes portadores do TIPS, e vários parâmetros são descritos na literatura para o diagnóstico de estenose, como: as velocidades mínima e máxima no interior da prótese, a velocidade na veia porta, o gradiente de velocidade entre dois pontos da prótese, e outros. Infelizmente não há consenso sobre qual parâmetro ou conjunto de parâmetros é mais eficaz no diagnóstico, porque os protocolos de avaliação variam de instituição para instituição. Os autores realizaram uma revisão dos parâmetros de estenose descritos na literatura e de outros aspectos de fundamental importância na compreensão do procedimento, como as indicações, as contra-indicações e a fisiopatologia da estenose.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.