Chemical ozone destruction occurs over both polar regions in local winter-spring. In the Antarctic, essentially complete removal of lower-stratospheric ozone currently results in an ozone hole every year, whereas in the Arctic, ozone loss is highly variable and has until now been much more limited. Here we demonstrate that chemical ozone destruction over the Arctic in early 2011 was--for the first time in the observational record--comparable to that in the Antarctic ozone hole. Unusually long-lasting cold conditions in the Arctic lower stratosphere led to persistent enhancement in ozone-destroying forms of chlorine and to unprecedented ozone loss, which exceeded 80 per cent over 18-20 kilometres altitude. Our results show that Arctic ozone holes are possible even with temperatures much milder than those in the Antarctic. We cannot at present predict when such severe Arctic ozone depletion may be matched or exceeded.
Abstract. The GCOS (Global Climate Observing System) Reference Upper-Air Network (GRUAN) data processing for the Vaisala RS92 radiosonde was developed to meet the criteria for reference measurements. These criteria stipulate the collection of metadata, the use of well-documented correction algorithms, and estimates of the measurement uncertainty. An important and novel aspect of the GRUAN processing is that the uncertainty estimates are vertically resolved. This paper describes the algorithms that are applied in version 2 of the GRUAN processing to correct for systematic errors in radiosonde measurements of pressure, temperature, humidity, and wind, as well as how the uncertainties related to these error sources are derived. Currently, the RS92 is launched on a regular basis at 13 out of 15 GRUAN sites. An additional GRUAN requirement for performing reference measurements with the RS92 is that the manufacturerprescribed procedure for the radiosonde's preparation, i.e. heated reconditioning of the sensors and recalibration during ground check, is followed. In the GRUAN processing however, the recalibration of the humidity sensors that is applied during ground check is removed. For the dominant error source, solar radiation, laboratory experiments were performed to investigate and model its effect on the RS92's temperature and humidity measurements. GRUAN uncertainty estimates are 0.15 K for night-time temperature measurements and approximately 0.6 K at 25 km during daytime. The other uncertainty estimates are up to 6 % relative humidity for humidity, 10-50 m for geopotential height, 0.6 hPa for pressure, 0.4-1 m s −1 for wind speed, and 1 • for wind direction. Daytime temperature profiles for GRUAN and Vaisala processing are comparable and consistent within the estimated uncertainty. GRUAN daytime humidity profiles are up to 15 % moister than Vaisala processed profiles, of which two-thirds is due to the radiation dry bias correction and onethird is due to an additional calibration correction. Redundant measurements with frost point hygrometers (CFH and NOAA FPH) show that GRUAN-processed RS92 humidity profiles and frost point data agree within 15 % in the troposphere. No systematic biases occur, apart from a 5 % dry bias for GRUAN data around −40 • C at night.
Abstract. Since September 2014, NASA's Orbiting Carbon Observatory-2 (OCO-2) satellite has been taking measurements of reflected solar spectra and using them to infer atmospheric carbon dioxide levels. This work provides details of the OCO-2 retrieval algorithm, versions 7 and 8, used to derive the column-averaged dry air mole fraction of atmospheric CO2 (XCO2) for the roughly 100 000 cloud-free measurements recorded by OCO-2 each day. The algorithm is based on the Atmospheric Carbon Observations from Space (ACOS) algorithm which has been applied to observations from the Greenhouse Gases Observing SATellite (GOSAT) since 2009, with modifications necessary for OCO-2. Because high accuracy, better than 0.25 %, is required in order to accurately infer carbon sources and sinks from XCO2, significant errors and regional-scale biases in the measurements must be minimized. We discuss efforts to filter out poor-quality measurements, and correct the remaining good-quality measurements to minimize regional-scale biases. Updates to the radiance calibration and retrieval forward model in version 8 have improved many aspects of the retrieved data products. The version 8 data appear to have reduced regional-scale biases overall, and demonstrate a clear improvement over the version 7 data. In particular, error variance with respect to TCCON was reduced by 20 % over land and 40 % over ocean between versions 7 and 8, and nadir and glint observations over land are now more consistent. While this paper documents the significant improvements in the ACOS algorithm, it will continue to evolve and improve as the CO2 data record continues to expand.
The comparison of simultaneous humidity measurements by the Vaisala RS92 radiosonde and by the Cryogenic Frostpoint Hygrometer (CFH) launched at Alajuela, Costa Rica, during July 2005 reveals a large solar radiation dry bias of the Vaisala RS92 humidity sensor and a minor temperature-dependent calibration error. For soundings launched at solar zenith angles between 10°and 30°, the average dry bias is on the order of 9% at the surface and increases to 50% at 15 km. A simple pressure-and temperature-dependent correction based on the comparison with the CFH can reduce this error to less than 7% at all altitudes up to 15.2 km, which is 700 m below the tropical tropopause. The correction does not depend on relative humidity, but is able to reproduce the relative humidity distribution observed by the CFH.
[1] A balloon flight to compare 18 ozonesondes with an ozone photometer and with ozone column measurements from Dobson and Brewer spectrophotometers was completed in April 2004. The core experiment consisted of 12 electrochemical concentration cell ozonesondes, 6 from Science Pump Corporation (SP) and 6 from ENSCI Corporation (ES), prepared with cathode solution concentrations of 0.5% KI (half buffer) and 1.0% KI (full buffer). Auxiliary ozonesondes consisted of two electrochemical concentration cell sondes with 2.0% KI (no buffer), two reconditioned sondes, and two Japanese-KC96 sondes. Precision of each group of similarly prepared ozonesondes was <2-3%. The six ozonesondes prepared according to the manufacturer's recommendations (SP, 1.0% KI, ES 0.5% KI) overestimated the photometer measurements by 5-10% in the stratosphere, but provided ozone columns in good agreement with the ground-based spectrophotometer measurements. This is consistent with the difference ($5%) in ozone photometer and column measurements observed during the experiment. Using cathode cell concentrations of 1.0% KI for ES sondes caused overestimates of the photometer by 10-15% and of ozone column by 5-10%. In contrast, 0.5% KI in SP sondes led to good agreement with the photometer, but underestimates of ozone column. The KC96 sondes underestimated the photometer measurements by about 5-15% at air pressures above 30 hPa. Agreement was within 5% at lower pressures. Diluting the solution concentration and the buffers from 1.0% to 0.5% KI causes an approximately linear pressure-dependent decrease in ozone for both SP and ES sondes, ratio (0.5 KI/1.0 KI) = 0.9 + 0.024 * log 10 (Pressure).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.