In state-of-the-art electroencephalography (EEG) Silver/Silver-Chloride electrodes are applied together with electrolyte gels or pastes. Their application requires extensive preparation, trained medical staff and limits measurement time and mobility. We recently proposed a novel multichannel cap system for dry EEG electrodes for mobile and out-of-the-lab EEG acquisition. During the tests with these novel polymer-based multipin dry electrodes, we observed that the quality of the recording depends on the applied normal force and resulting contact pressure. Consequently, in this paper we systematically investigate the influence of electrode-skin contact pressure and electrode substrate flexibility on interfacial impedance and perceived wearing comfort in a study on 12 volunteers. The normal force applied to the electrode was varied between the minimum required force to achieve impedances and a maximum of 4 N, using a new force measurement applicator. We found that for a polymer shore hardness A98, with increasing normal force, the impedance decreases from and to and at frontal hairless and temporal hairy positions, respectively. Similar results were obtained for shore A90, A80, and A70. The best compromise of low and stable impedances as well as a good wearing comfort was determined for applied normal forces between 2 and 3 N using electrodes with shore A98 or A90. Our results provide the basis for improved EEG cap designs with optimal wearing comfort and recording quality for dry multipin electrodes, which will enable new fields of application for EEG.
Electrode and cap concepts for continuous and ubiquitous monitoring of brain activity will open up new fields of application and contribute to increased use of electroencephalography (EEG) in clinical routine, neurosciences, brain-computer-interfacing and out-of-the-lab monitoring. However, mobile and unobtrusive applications are currently hindered by the lack of applicable convenient and reliable electrode and cap systems. We propose a novel modular electrode concept based on a flexible polymer substrate, coated with electrically conductive metallic films. The overall concept enables design adaptation to different head regions and cap designs. We describe the single modules of the system and investigate the influence of electrode pin number, coating material and adduction force on electrode-skin impedance and perceived wearing comfort. Our results contribute to rapid and comfortable multichannel dry EEG.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.