Mandible defects are conventionally reconstructed using titanium plates. However, titanium causes metallic artifacts which impair radiological imaging. This study aims at evaluating mechanical fatigue of radiolucent fiber-reinforced polyetheretherketone (f-PEEK), polyetheretherketone (PEEK), polyetherketoneketone (PEKK), and polyphenylsulfone (PPSU) polymer plates for mandible reconstruction. A total of 30 plates (titanium [n = 6], f-PEEK [n = 6], PEEK [n = 6], PEKK [n = 6], PPSU [n = 6]) were implanted in synthetic mandibulectomized polyurethane mandibles. Servo-pneumatic mechanical testing with cyclic application of 30–300 N at 3 Hz was conducted. Bite forces were 70% on the unresected and 30% on the resected side. Total number of cycles was set to 250,000. Testing was aborted in case of plate or screw failure. Axial load to failure was tested with a speed of 1 mm/s. Kruskal–Wallis and Dunn’s post hoc tests were used. Titanium, f-PEEK, and PEEK showed no failure in fatigue testing and PPSU (p < 0.001) failed against titanium, f-PEEK, PEEK, and PEKK. Titanium allowed the highest load to failure compared to f-PEEK (p = 0.049), PEEK (p = 0.008), PEKK (p < 0.001), and PPSU (p = 0.007). f-PEEK, PEEK, and PEKK withstood expected physiological bite force. Although titanium plates provided the highest fatigue strength, f-PEEK and PEEK plates showed no failure over 250,000 chewing cycles indicating sufficient mechanical strength for mandible reconstruction.
The present systematic review investigated the concentration of chromium (Cr) and cobalt (Co) in serum in patients who have undergone total hip arthroplasty (THA). The first outcome of interest was to investigate the mean concentration in serum of Cr and Co using different material combinations and to verify whether their concentrations change significantly using different patterns of head and liner in THA. The second outcome of interest was to investigate whether the time elapsed from the index surgery to the follow-up, BMI, sex, and side exert an influence on the mean concentration of Cr and Co in serum in patients who have undergone THA. The following material combinations were investigated (head-liner): Ceramic-Co Cr (CoCr), CoCr-CoCr, CoCr-Polyethylene, CoCr high carbide-CoCr high carbide. Data from 2756 procedures were retrieved. The mean length of follow-up was 69.3 ± 47.7 months. The ANOVA test evidenced good comparability in age, length of follow-up, BMI, and sex (P > 0.1). In patients who have undergone THA, the mean concentration in the serum of Co ranged between 0.5 µg/L and 3.5 µg/L, and the mean concentration of Cr from 0.6 to 2.6 µg/L. The difference in the concentration of Co and Cr in serum is strictly related to the implant configuration, with the coupling CoCr-CoCr showing the highest and CoCr-Polyethylene showing the lowest concentration. Patient characteristics, BMI, sex, side and the time elapsed from the index surgery to the last follow-up did not exert a significant influence on the concentration of Co and Cr in serum in patients who have undergone total hip arthroplasty (THA).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.