Aims The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). Patients and Methods In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors. Results The revision-free survival of the implant was 71% at five years and 63.3% at ten years. Three prostheses reached 15 years without revision. The mean Musculoskeletal Tumor Society score in the group was 26 (23 to 28). The mechanisms of failure were infection in 18%, structural failures in 6%, tumour progression in 5%, aseptic loosening in 2%, and soft-tissue failures in 1%. Prostheses used for primary reconstruction after oncological resections had lower infection rates than revision implants (8% vs 25%; p = 0.001). The rates of infection in silver-coated and non-silver-coated prosthesis were similar (17.4% vs 19.%; p = 0.869). The incidence of hip dislocation was 10%. Rotating hinge prosthesis had a lower failure rate than fixed hinge prosthesis (5.3% vs 11%). After Cox regression, the independent factors associated with failures were the history of previous operations (hazard ratio (HR) 3.7; p = 0.041), and the associated arthroplasty of the proximal tibia (HR 3.8; p = 0.034). At last follow-up, 11 patients (13%) required amputation. Conclusion TFEPR offers a reliable reconstruction option for massive bone loss of the femur, with a good survival when the prosthesis is used as a primary implant. The use of a rotating hinge at the knee and dual mobility bearing at the hip may be adequate to reduce the risk of mechanical and soft-tissue failures. Infection remains the main concern and there is insufficient evidence to support the routine use of silver-coated endoprosthesis. Cite this article: Bone Joint J 2019;101-B:522–528.
Aims Limb salvage for pelvic sarcomas involving the acetabulum is a major surgical challenge. There remains no consensus about what is the optimum type of reconstruction after resection of the tumour. The aim of this study was to evaluate the surgical outcomes in these patients according to the methods of periacetabular reconstruction. Methods The study involved a consecutive series of 122 patients with a periacetabular bone sarcoma who underwent limb-salvage surgery involving a custom-made prosthesis in 65 (53%), an ice-cream cone prosthesis in 21 (17%), an extracorporeal irradiated autograft in 18 (15%), and nonskeletal reconstruction in 18 (15%). Results The rates of major complications necessitating further surgery were 62%, 24%, 56%, and 17% for custom-made prostheses, ice-cream cone prostheses, irradiated autografts and nonskeletal reconstructions, respectively (p = 0.001). The ten-year cumulative incidence of failure of the reconstruction was 19%, 9%, 33%, and 0%, respectively. The major cause of failure was deep infection (11%), followed by local recurrence (6%). The mean functional Musculoskeletal Tumour Society (MSTS) scores were 59%, 74%, 64%, and 72%, respectively. The scores were significantly lower in patients with major complications than in those without complications (mean 52% (SD 20%) vs 74% (SD 19%); p < 0.001). For periacetabular resections involving the ilium, the mean score was the highest with custom-made prostheses (82% (SD 10%)) in patients without any major complication; however, nonskeletal reconstruction resulted in the highest mean scores (78% (SD 12%)) in patients who had major complications. For periacetabular resections not involving the ilium, significantly higher mean scores were obtained with ice-cream cone prostheses (79% (SD 17%); p = 0.031). Conclusion Functional outcome following periacetabular reconstruction is closely associated with the occurrence of complications requiring further surgery. For tumours treated with periacetabular and iliac resection, skeletal reconstruction may result in the best outcomes in the absence of complications, whereas nonskeletal reconstruction is a reasonable option if the risk of complications is high. For tumours requiring periacetabular resection without the ilium, reconstruction using an ice-cream cone prosthesis supported by antibiotic-laden cement is a reliable option. Cite this article: Bone Joint J 2021;103-B(4):795–803.
Purpose The purpose of this study was to clarify which local treatment is oncologically and functionally effective in pelvic Ewing sarcoma (ES). Methods A consecutive series of patients who underwent pelvic resections and acetabular reconstructions after chemotherapy between 1986 and 2016 at a supra‐regional center were evaluated. Results The cohort consisted of 35 patients. The 5‐year overall survival (OS) and local recurrence‐free survival (LRFS) was 61% and 72%, respectively. Preoperative radiotherapy (RT) and surgery provided an excellent/good histological response in 92% and achieved significantly better OS (5 years, 64%) and LRFS (5 years, 100%) than surgery alone or surgery with postoperative RT. The Musculoskeletal Tumor Society functional scores were significantly better in patients with hip transposition than those with structural reconstructions (74% vs 57%; P = .031) using custom‐made prostheses, irradiated autografts, and ice‐cream cone prostheses. These scores were significantly lower if patients had deep infection (P = .035), which was the most common complication (28%) in structural reconstructions but did not occur in hip transposition even when performed after preoperative RT. Conclusion Acetabular reconstruction with hip transposition resulted in no deep infection and superior function in patients with pelvic ES even when combined with preoperative RT, which improved tumor necrosis and rate of local control and survival.
The six studied CT splenic injury grading scales did not have a high enough interrater reliability to be adequate for clinical use. The poor interrater reliability is likely to contribute to the failure of the scales at predicting clinical outcomes. Further research to improve the interrater reliability is recommended.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.