We have developed an LSI-based amperometric sensor called "Bio-LSI" with 400 measurement points as a platform for electrochemical bio-imaging and multi-point biosensing. The system is comprised of a 10.4 mm × 10.4 mm CMOS sensor chip with 20 × 20 unit cells, an external circuit box, a control unit for data acquisition, and a DC power box. Each unit cell of the chip contains an operational amplifier with a switched-capacitor type I-V converter for in-pixel signal amplification. We successfully realized a wide dynamic range from ±1 pA to ±100 nA with a well-organized circuit design and operating software. In particular, in-pixel signal amplification and an original program to control the signal read-out contribute to the lower detection limit and wide detection range of Bio-LSI. The spacial resolution is 250 μm and the temporal resolution is 18-125 ms/400 points, which depends on the desired current detection range. The coefficient of variance of the current for 400 points is within 5%. We also demonstrated the real-time imaging of a biological molecule using Bio-LSI. The LSI coated with an Os-HRP film was successfully applied to the monitoring of the changes of hydrogen peroxide concentration in a flow. The Os-HRP-coated LSI was spotted with glucose oxidase and used for bioelectrochemical imaging of the glucose oxidase (GOx)-catalyzed oxidation of glucose. Bio-LSI is a promising platform for a wide range of analytical fields, including diagnostics, environmental measurements and basic biochemistry.
We have developed a large-scale integrated (LSI) complementary metal-oxide semiconductor (CMOS)-based amperometric sensor array system called "Bio-LSI" as a platform for electrochemical bio-imaging and multi-point biosensing with 400 measurement points. In this study, we newly developed a Bio-LSI chip with a light-shield structure and a mode-selectable function with the aim of extending the application range of Bio-LSI. The light shield created by the top metal layer of the LSI chip significantly reduces the noise generated by the photocurrent, whose value is less than 1% of the previous Bio-LSI without the light shield. The mode-selectable function enables the individual operation of 400 electrodes in off, electrometer, V1, and V2 mode. The off-mode cuts the electrode from the electric circuit. The electrometer-mode reads out the electrode potential. The V1-mode and the V2-mode set the selected sensor electrode at two different independent voltages and read out the current. We demonstrated the usefulness of the mode-selectable function. First, we displayed a dot picture based on the redox reactions of 2.0 mM ferrocenemethanol at 400 electrodes by applying two different independent voltages using the V1 and V2 modes. Second, we carried out a simultaneous detection of O2 and H2O2 using the V1 and V2 modes. Third, we used the off and V1 modes for the modification of the osmium-polyvinylpyridine gel polymer containing horseradish peroxidase (Os-HRP) at the selected electrodes, which act as sensors for H2O2. These results confirm that the advanced version of Bio-LSI is a promising tool that can be applied to a wide range of analytical fields.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.