Objectives This goal of this study was to create and validate a new set of sentence lists that could be used to evaluate the speech perception abilities of hearing impaired listeners and cochlear implant users. Our intention was to generate a large number of sentence lists with an equivalent level of difficulty for the evaluation of performance over time and across conditions. Design The AzBio sentence corpus includes 1000 sentences recorded from 2 female and 2 male talkers. The mean intelligibility of each sentence was estimated by processing each sentence through a 5-channel cochlear implant simulation and calculating the mean percent correct score achieved by 15 normal-hearing listeners. Sentences from each talker were sorted by percent correct score and 165 sentences were selected from each talker and were then sequentially assigned to 33 lists, each containing 20 sentences (5 sentences from each talker). List equivalency was validated by presenting all lists, in random order, to 15 cochlear implant users. Results Using sentence scores from the cochlear implant simulation study produced 33 lists of sentences with a mean score of 85% correct. The results of the validation study with cochlear implant users revealed no significant differences in percent correct scores for 29 of the 33 sentence lists. However, individual listeners demonstrated considerable variability in performance on the 29 lists. The binomial distribution model was used to account for the inherent variability observed in the lists. This model was also used to generate 95% confidence intervals for one and two list comparisons. A retrospective analysis of 172 instances where research subjects had been tested on two lists within a single condition revealed that 94% of results were accurately contained within these confidence intervals. Conclusions The use of a 5-channel cochlear implant simulation to estimate the intelligibility of individual sentences allowed for the creation of a large number of sentence lists with an equivalent level of difficulty. The results of the validation procedure with cochlear implant users found that 29 of 33 lists allowed scores that were not statistically different. However, individual listeners demonstrated considerable variability in performance across lists. This variability was accurately described by the binomial distribution model and was used to estimate the magnitude of change required to achieve statistical significance when comparing scores from one and two lists per condition. Fifteen sentence lists have been included in the AzBio Sentence Test, for use in the clinical evaluation of hearing impaired listeners and cochlear implant users. An additional 8 sentence lists have been included in the Minimum Speech Test Battery to be distributed by the cochlear implant manufacturers for the evaluation of cochlear implant candidates.
Objectives/Hypothesis Three surgical approaches: cochleostomy (C), round window (RW), and extended round window (ERW); and two electrodes types: lateral wall (LW) and perimodiolar (PM), account for the vast majority of cochlear implantations. The goal of this study was to analyze the relationship between surgical approach and electrode type with final intracochlear position of the electrode array and subsequent hearing outcomes. Study Design Comparative longitudinal study. Methods One hundred postlingually implanted adult patients were enrolled in the study. From the postoperative scan, intracochlear electrode location was determined and using rigid registration, transformed back to the preoperative computed tomography which had intracochlear anatomy (scala tympani and scala vestibuli) specified using a statistical shape model based on 10 microCT scans of human cadaveric cochleae. Likelihood ratio chi-square statistics were used to evaluate for differences in electrode placement with respect to surgical approach (C, RW, ERW) and type of electrode (LW, PM). Results Electrode placement completely within the scala tympani (ST) was more common for LW than were PM designs (89% vs. 58%; P < 0.001). RW and ERW approaches were associated with lower rates of electrode placement outside the ST than was the cochleostomy approach (9%, 16%, and 63%, respectively; P < 0.001). This pattern held true regardless of whether the implant was LW or PM. When examining electrode placement and hearing outcome, those with electrode residing completely within the ST had better consonant-nucleus-consonant word scores than did patients with any number of electrodes located outside the ST (P = 0.045). Conclusion These data suggest that RW and ERW approaches and LW electrodes are associated with an increased likelihood of successful ST placement. Furthermore, electrode position entirely within the ST confers superior audiological outcomes. Level Of Evidence 2b.
Cochlear implant recipients have demonstrated remarkable increases in speech perception since US FDA approval was granted in 1984. Improved performance is due to a number of factors including improved cochlear implant technology, evolving speech coding strategies, and individuals with increasingly more residual hearing receiving implants. Despite this evolution, the same recommendations for pre- and postimplant speech recognition testing have been in place for over 10 years in the United States. To determine whether new recommendations are warranted, speech perception performance was assessed for 156 adult, postlingually deafened implant recipients as well as 50 hearing aid users on monosyllabic word recognition (CNC) and sentence recognition in quiet (HINT and AzBio sentences) and in noise (BKB-SIN). Results demonstrated that for HINT sentences in quiet, 28% of the subjects tested achieved maximum performance of 100% correct and that scores did not agree well with monosyllables (CNC) or sentence recognition in noise (BKB-SIN). For a more difficult sentence recognition material (AzBio), only 0.7% of the subjects achieved 100% performance and scores were in much better agreement with monosyllables and sentence recognition in noise. These results suggest that more difficult materials are needed to assess speech perception performance of postimplant patients – and perhaps also for determining implant candidacy.
Fifteen patients fit with a cochlear implant in one ear and a hearing aid in the other ear were presented with tests of speech and melody recognition and voice discrimination under conditions of electric (E) stimulation, acoustic (A) stimulation and combined electric and acoustic stimulation (EAS). When acoustic information was added to electrically stimulated information performance increased by 17–23 percentage points on tests of word and sentence recognition in quiet and sentence recognition in noise. On average, the EAS patients achieved higher scores on CNC words than patients fit with a unilateral cochlear implant. While the best EAS patients did not outperform the best patients fit with a unilateral cochlear implant, proportionally more EAS patients achieved very high scores on tests of speech recognition than unilateral cochlear implant patients.
Objective To describe the relationship between implantation-associated trauma and postoperative speech perception scores among adult and pediatric patients undergoing cochlear implantation using conventional length electrodes and minimally traumatic surgical techniques. Study Design Retrospective chart review (2002–2010). Setting Tertiary academic referral center. Patients All subjects with significant preoperative low-frequency hearing (≤70 dB HL at 250 Hz) who underwent cochlear implantation with a newer generation implant electrode (Nucleus Contour Advance, Advanced Bionics HR90K [1J and Helix], and Med El Sonata standard H array) were reviewed. Intervention(s) Preimplant and postimplant audiometric thresholds and speech recognition scores were recorded using the electronic medical record. Main Outcome Measure(s) Postimplantation pure tone threshold shifts were used as a surrogate measure for extent of intracochlear injury and correlated with postoperative speech perception scores. Results Between 2002 and 2010, 703 cochlear implant (CI) operations were performed. Data from 126 implants were included in the analysis. The mean preoperative low-frequency pure-tone average was 55.4 dB HL. Hearing preservation was observed in 55% of patients. Patients with hearing preservation were found to have significantly higher postoperative speech perception performance in the cochlear implantation-only condition than those who lost all residual hearing. Conclusion Conservation of acoustic hearing after conventional length cochlear implantation is unpredictable but remains a realistic goal. The combination of improved technology and refined surgical technique may allow for conservation of some residual hearing in more than 50% of patients. Germane to the conventional length CI recipient with substantial hearing loss, minimizing trauma allows for improved speech perception in the electric condition. These findings support the use of minimally traumatic techniques in all CI recipients, even those destined for electric-only stimulation.
Objective The aim of this study was to assess the benefit of having preserved acoustic hearing in the implanted ear for speech recognition in complex listening environments. Design The current study included a within subjects, repeated-measures design including 21 English speaking and 17 Polish speaking cochlear implant recipients with preserved acoustic hearing in the implanted ear. The patients were implanted with electrodes that varied in insertion depth from 10 to 31 mm. Mean preoperative low-frequency thresholds (average of 125, 250 and 500 Hz) in the implanted ear were 39.3 and 23.4 dB HL for the English- and Polish-speaking participants, respectively. In one condition, speech perception was assessed in an 8-loudspeaker environment in which the speech signals were presented from one loudspeaker and restaurant noise was presented from all loudspeakers. In another condition, the signals were presented in a simulation of a reverberant environment with a reverberation time of 0.6 sec. The response measures included speech reception thresholds (SRTs) and percent correct sentence understanding for two test conditions: cochlear implant (CI) plus low-frequency hearing in the contralateral ear (bimodal condition) and CI plus low-frequency hearing in both ears (best aided condition). A subset of 6 English-speaking listeners were also assessed on measures of interaural time difference (ITD) thresholds for a 250-Hz signal. Results Small, but significant, improvements in performance (1.7 – 2.1 dB and 6 – 10 percentage points) were found for the best-aided condition vs. the bimodal condition. Postoperative thresholds in the implanted ear were correlated with the degree of EAS benefit for speech recognition in diffuse noise. There was no reliable relationship among measures of audiometric threshold in the implanted ear nor elevation in threshold following surgery and improvement in speech understanding in reverberation. There was a significant correlation between ITD threshold at 250 Hz and EAS-related benefit for the adaptive SRT. Conclusions Our results suggest that (i) preserved low-frequency hearing improves speech understanding for CI recipients (ii) testing in complex listening environments, in which binaural timing cues differ for signal and noise, may best demonstrate the value of having two ears with low-frequency acoustic hearing and (iii) preservation of binaural timing cues, albeit poorer than observed for individuals with normal hearing, is possible following unilateral cochlear implantation with hearing preservation and is associated with EAS benefit. Our results demonstrate significant communicative benefit for hearing preservation in the implanted ear and provide support for the expansion of cochlear implant criteria to include individuals with low-frequency thresholds in even the normal to near-normal range.
A full-insertion cochlear implant provides better speech understanding than bilateral, low-frequency residual hearing. The combination of an implant and contralateral acoustic hearing yields comparable performance to that of patients with a partially inserted implant and bilateral, low-frequency acoustic hearing. These data suggest that a full-insertion cochlear implant is a viable treatment option for patients with low-frequency residual hearing.
Over the last 20 years, cochlear implants (CIs) have become what is arguably the most successful neural prosthesis to date. Despite this success, a significant number of CI recipients experience marginal hearing restoration, and, even among the best performers, restoration to normal fidelity is rare. In this article, we present image processing techniques that can be used to detect, for the first time, the positions of implanted CI electrodes and the nerves they stimulate for individual CI users. These techniques permit development of new, customized CI stimulation strategies. We present one such strategy and show that it leads to significant hearing improvement in an experiment conducted with 11 CI recipients. These results indicate that image-guidance can be used to improve hearing outcomes for many existing CI recipients without requiring additional surgical procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.