No abstract
Magnetic resonance (MR) imaging methods with good spatial and contrast resolution are often too slow to follow the uptake of contrast agents with the desired temporal resolution. Imaging can be accelerated by skipping the acquisition of data normally taken with strong phase-encoding gradients, restricting acquisition to weak-gradient data only. If the usual procedure of substituting zeroes for the missing data is followed, blurring results. Substituting instead reference data taken before or well after contrast agent injection reduces this problem. Volunteer and patient images obtained by using such reference data show that imaging can be usefully accelerated severalfold. Cortical and medullary regions of interest and whole kidney regions were studied, and both gradient- and spin-echo images are shown. The method is believed to be compatible with other acceleration methods such as half-Fourier reconstruction and reading of more than one line of k space per excitation.
Recent technologic advances in computed tomography (CT)--enabling the nearly simultaneous acquisition of clinical images using two different x-ray energy spectra--have sparked renewed interest in dual-energy CT. By interrogating the unique characteristics of different materials at different x-ray energies, dual-energy CT can be used to provide quantitative information about tissue composition, overcoming the limitations of attenuation-based conventional single-energy CT imaging. In the past few years, intensive research efforts have been devoted to exploiting the unique and powerful opportunities of dual-energy CT for a variety of clinical applications. This has led to CT protocol modifications for radiation dose reduction, improved diagnostic performance for detection and characterization of diseases, as well as image quality optimization. In this review, the authors discuss the basic principles, instrumentation and design, examples of current clinical applications in the abdomen and pelvis, and future opportunities of dual-energy CT.
Compared with standard FBP reconstruction, an ASIR algorithm improves image quality and has the potential to decrease radiation dose at low-tube-voltage, high-tube-current multidetector abdominal CT during the late hepatic arterial phase.
Ferumoxytol is an ultrasmall superparamagnetic iron oxide (USPIO) agent initially approved by the Food and Drug Administration (FDA) as an iron replacement therapy for patients with anemia due to chronic renal failure. Recently, ferumoxytol has been investigated extensively as an intravenous contrast agent in magnetic resonance imaging (MRI). Since it causes regional T1 and T2 * shortening in vivo, conventional pulse sequences can be used following ferumoxytol administration to demonstrate signal enhancement or loss. Ferumoxytol can be administered as a rapid bolus and has a long intravascular half-life on the order of 14-15 hours, making it a potentially useful agent for vascular and perfusion-weighted MRI. In comparison to other USPIOs, ferumoxytol is less limited by allergic and idiosyncratic reactions. Furthermore, since ferumoxytol is an iron-based agent with no potential for causing nephrogenic systemic fibrosis, it may be useful as an alternative to gadolinium-based contrast agents in patients with compromised renal function. Ferumoxytol is ultimately taken up by macrophages/the reticuloendothelial system in the liver, spleen, and lymph nodes, and this uptake mechanism is being explored as a novel imaging technique for vascular lesions, tumors, and lymph nodes. This article reviews the properties of ferumoxytol relevant to MRI as well as many of the uses for the agent currently under investigation.
While the benefits of exercise are clear, many unresolved issues surround the optimal exercise prescription. Many organizations recommend aerobic training (AT) and resistance training (RT), yet few studies have compared their effects alone or in combination. The purpose of this study, part of Studies Targeting Risk Reduction Interventions Through Defined Exercise-Aerobic Training and/or Resistance Training (STRRIDE/ AT/RT), was to compare the effects of AT, RT, and the full combination (AT/RT) on central ectopic fat, liver enzymes, and fasting insulin resistance [homeostatic model assessment (HOMA)]. In a randomized trial, 249 subjects [18 -70 yr old, overweight, sedentary, with moderate dyslipidemia (LDL cholesterol 130 -190 mg/dl or HDL cholesterol Յ40 mg/dl for men or Յ45 mg/dl for women)] performed an initial 4-mo run-in period. Of these, 196 finished the run-in and were randomized into one of the following 8-mo exercise-training groups: 1) RT, which comprised 3 days/wk, 8 exercises, 3 sets/ exercise, 8 -12 repetitions/set, 2) AT, which was equivalent to ϳ19.2 km/wk (12 miles/wk) at 75% peak O2 uptake, and 3) full AT ϩ full RT (AT/RT), with 155 subjects completing the intervention. The primary outcome variables were as follows: visceral and liver fat via CT, plasma liver enzymes, and HOMA. AT led to significant reductions in liver fat, visceral fat, alanine aminotransferase, HOMA, and total and subcutaneous abdominal fat (all P Ͻ 0.05). RT resulted in a decrease in subcutaneous abdominal fat (P Ͻ 0.05) but did not significantly improve the other variables. AT was more effective than RT at improving visceral fat, liver-to-spleen ratio, and total abdominal fat (all P Ͻ 0.05) and trended toward a greater reduction in liver fat score (P Ͻ 0.10). The effects of AT/RT were statistically indistinguishable from the effects of AT. These data show that, for overweight and obese individuals who want to reduce measures of visceral fat and fatty liver infiltration and improve HOMA and alanine aminotransferase, a moderate amount of aerobic exercise is the most time-efficient and effective exercise mode. aerobic training; liver fat; resistance training; weight lifting; homeostasis model assessment WHILE THE BENEFITS OF BEING physically active are clear, many unresolved issues surround the optimal exercise prescription for these benefits. Many organizations recommend both aerobic training (AT) and resistance training (RT) for all adults. However, these recommendations are mainly based on the evaluation of each modality separately, as few studies have investigated the effects of combined AT and RT regimens compared with each modality individually. Furthermore, adherence to exercise recommendations of physicians is notoriously poor, and many patients cite lack of time as a reason for noncompliance. Understanding the effects of AT and RT is of critical importance if we are to apply evidence-based approaches to exercise recommendations to a wide population.Visceral fat and liver fat are associated with type 2 diabetes, metaboli...
Dual-energy CT provides information about how substances behave at different energies, the ability to generate virtual unenhanced datasets, and improved detection of iodine-containing substances on low-energy images. Knowing how a substance behaves at two different energies can provide information about tissue composition beyond that obtainable with single-energy techniques. The term K edge refers to the spike in attenuation that occurs at energy levels just greater than that of the K-shell binding because of the increased photoelectric absorption at these energy levels. K-edge values vary for each element, and they increase as the atomic number increases. The energy dependence of the photoelectric effect and the variability of K edges form the basis of dual-energy techniques, which may be used to detect substances such as iodine, calcium, and uric acid crystals. The closer the energy level used in imaging is to the K edge of a substance such as iodine, the more the substance attenuates. In the abdomen and pelvis, dual-energy CT may be used in the liver to increase conspicuity of hypervascular lesions; in the kidneys, to distinguish hyperattenuating cysts from enhancing renal masses and to characterize renal stone composition; in the adrenal glands, to characterize adrenal nodules; and in the pancreas, to differentiate between normal and abnormal parenchyma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.