BackgroundUnderstanding normal gait requires allowing for variations in normal patterns by the sex, age, and species in question. Therefore, the aim of this study was to evaluate kinetic and temporospatial parameters in clinically healthy sheep from three different age groups with a pressure-sensing walkway. The sheep were judged to be healthy based on the results of complete physical and orthopaedic examinations and had no history of lameness. Twenty-one clinically healthy female Santa Ines sheep were divided into three groups: G1 – seven animals, aged from 8 to 12 months and weighing 19.5-33 kg; G2 - seven individuals, aged from 2 to 4 years and weighing 26.5-42 kg; and G3 - seven sheep, aged more than 5 years and weighing 37.3-45 kg. The animals were examined from two directions: first on the left side and then on the right side of the handler. The data from the first five valid trials in each direction were collected for each sheep and analysed using the designated software. A trial was considered valid if the sheep walked within the correct velocity (1.1-1.3 m/s) and acceleration (from −0.15 to 0.15 m/s2) ranges. The peak vertical force (PVF), vertical impulse (VI), gait cycle time, stance time, swing time, stride length, and the percentage body weight distribution among the four limbs were determined.ResultsNo significant differences were observed, in either the forelimbs or the hind limbs, between the left and right sides or between the two directions for any of the variables. No significant temporospatial differences were found among the groups. Significant PVF (%BW) differences were observed in the forelimbs (G1 > G3) and hind limbs (G1 > G3), and significant VI differences were observed in the forelimbs (G1 > G3).ConclusionsYoung healthy sheep differ from older sheep in the vertical forces they create when walking at the same velocity on a pressure-sensing walkway.
Pesq. Vet. Bras. 32(8):812-816, agosto 2012 812 RESUMO.-O trabalho teve por objetivo comparar os valores goniométricos das articulações dos membros torácicos e pélvicos em ovinos da raça Santa Inês em duas faixas etá-rias (jovens e adultos). Foram utilizados 30 ovinos hígidos, fêmeas, divididos em dois grupos: Grupo 1 com 15 animais jovens (idade entre 6 e 12 meses), Grupo 2 com 15 animais adultos (entre 3 e 6 anos). Foram aferidas a máxima ϐlexão, a máxima extensão e calculou-se a amplitude de movimen- The purpose of this study was to compare goniometric values for forelimb and hind limbs in clinically healthy Santa Ines sheep with two ages (young and adult). Thirty female Santa Ines sheep were separated into two groups of 15 animals each: Group 1 with 6 to 12-month-old sheep (classiϐied as young), and Group 2 with 3 to 6-year-old sheep (classiϐied as adult). Maximum ϐlexion, maximum extension, and range of motion (ROM) of the shoulder, elbow, carpal, hip, stiϐle, and tarsal joints, in the right and left limbs were measured with a standard transparent plastic goniometer. The measurements were performed in triplicate by two independent investigators with the sheep in a standing position. There was no statistically signiϐicant difference between the right and left sides, between investigators or between groups. In conclusion, in clinically healthy sheep the goniometric values were not inϐluenced by age.
The objective of this study was to compare waveforms obtained with a new device for the non-invasive monitoring of intracranial pressure (ICP) in dogs with and without neurological disease. Materials and MethOds:This prospective study was conducted on both neurologically normal dogs and dogs with neurological diseases. First, non-invasive ICP waveforms were recorded in normal dogs using the Braincare® BcMM 2000 monitor while the dogs were under general anaesthesia induced for procedures unrelated to this study. The dogs were positioned in lateral recumbency, and the sensor was placed over the skin of the parietal region. Secondly, non-invasive ICP waveforms were monitored in dogs with brain and spinal disease until waveforms with characteristic peaks were acquired. All the recorded signals were amplified, filtered and digitalized, by the device, and then transferred to a computer for analysis.results: Normal pulse waveforms indicating normal brain complacency were observed in eight neurologically normal dogs. In six dogs with brain disease, abnormal pulse waveforms were observed suggesting increased ICP and decreased brain complacency. Four dogs with spinal disease undergoing myelography, had normal waveforms before contrast medium injection and abnormal pulse waveforms during contrast medium injection, indicating a potential increase in ICP. clinical significance: Based on these preliminary observations, this method was capable of detecting abnormal pulse waveforms that suggested increased ICP.
RESUMO O objetivo deste estudo foi utilizar a sonda uretral flexível como método alternativo para aferição da pressão intracraniana em coelhos com trauma cranioencefálico induzido pelo cateter de Fogarty 4 Fr (balão epidural) e comparar os dados obtidos com o método convencional de cateter de ventriculostomia. Foram utilizados 12 coelhos, machos, adultos, distribuídos aleatoriamente em dois grupos, denominados de G1: mensuração da PIC com cateter de ventriculostomia (n=6) e G2: mensuração com sonda uretral (n=6). Foram realizadas duas craniotomias na região parietal direita e esquerda para a implantação do cateter de ventriculostomia ou sonda uretral flexível e o balão epidural, respectivamente. A PAM, a PPC, a FC, a FR e a TR foram mensurados antes e após a craniotomia. A PIC foi avaliada após a craniotomia e a cada 10 minutos depois do preenchimento do balonete com 0,3mL de NaCl 0,9%, durante 40 minutos, e com 0,6mL, pelo mesmo período de tempo, totalizando 80 minutos. A PIC aumentou em ambos os grupos, sendo menores os valores registrados com a sonda uretral flexível. Foi possível reproduzir o aumento da PIC com o modelo experimental de TCE utilizando o cateter de Fogarty 4 Fr na região epidural e, embora haja a necessidade de outros estudos, a sonda uretral flexível demonstra ser um método alternativo de mensuração da PIC em coelhos com trauma cranioencefálico.Palavras-chave: cateter de ventriculostomia, autorregulação, neurologia, cirurgia ABSTRACT The aim of this study was to evaluate the use of flexible urethral catheter as an alternative method for measuring intracranial pressure in rabbits with head trauma induced by 4 F Fogarty catheter (epidural balloon) and compare the data obtained with the conventional method of ventriculostomy catheter. In this study, New Zealand rabbits were randomly distributed into two groups, G1: measuring the ICP with ventriculostomy catheter (n=6) and G2: measuring the ICP with urethral catheter (n=6
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.