Twenty patients were interviewed shortly after colonoscopy, and the adjectives and phrases they used to describe the experience were formed into a 31-item questionnaire, on which each item was rated using a seven-point scale. This questionnaire was completed by 110 similar patients. Principal components analysis of these responses yielded three components: satisfaction, physical discomfort, and emotional distress. This demonstrates that patients' experience of colonoscopy is multi-dimensional; whether or not a patient feels satisfied is unrelated to how distressing or uncomfortable it is. Component-based scale scores were calculated so as to quantify every patient's experience on each dimension. Procedures performed by the most experienced endoscopist were no less uncomfortable than others, but they were less distressing. Female patients experienced more discomfort than males, but were no more distressed or less satisfied. This questionnaire could be useful in any future audit of colonoscopy from the patients' point of view.
ABSTRACT… Objectives: We aim to evaluate the level of satisfaction after total knee arthroplasty procedure in the patient population at a tertiary care hospital in Karachi, Pakistan, and to assess the relationship between patient satisfaction and the outcome based on traditional scores. Methods: Study Design: Case series for determination of patient satisfaction. Period: One year duration from April 2015 to May 2016. Setting: Tertiary care centre in Karachi, Pakistan. The inclusion criteria was all the patients with late stage osteoarthritis of the knee joint and underwent total knee arthroplasty at our institute. Data was analyzed using SPSS version 22. Results: A total of n= 102 patients were included in the study while n= 109 knee surgeries were done in total (n= 95 patients had unilateral surgery, while n= 7 patients had bilateral surgeries on both the knee joints) n= 58 patients were females while n= 44 patients were males, the median age was 60 years, patients had a mean body mass index (BMI) of 27kg/ m 2 . Of the total surgeries performed n= 100 were in the satisfaction group while n= 9 were in the dissatisfaction group. The majority of the patients reported that they would recommend the procedure. The co morbid conditions did not affect the patient's level of satisfaction having a p value of 0.678. In the dissatisfied group, there was no significant difference when it comes to gender, the mean age of patients in the dissatisfaction group was higher than the mean age of patients in the satisfaction. We found that WOMAC scores for functioning and the final WOMAC scores were correlated with patient satisfaction and that was statistically significant, similarly SF-36 form patients were satisfied about the improvement in the physical health while they did not improve the mental health aspect of their disease. Conclusion: According to our study total knee arthroplasty is an effective treatment for osteoarthritis of the knee, patient satisfaction is correlated with post-operative WOMAC function and overall scores, and SF-36 physical component. It is important to keep patients expectations in check through proper counseling. Key words:Osteoarthritis; patient satisfaction; total knee arthroplasty; TKA. Article Citation: Jabbar FA, Shah RA, Hashim M. Total knee arthroplasty; Evaluation of the patient satisfaction, its comparison with traditional physician based scores, at Karachi, Pakistan.
Objectives: The aim of our study is to determine the outcome of cervical pediclescrew fixation for fractures/dislocations of the cervical spine at our set up in Karachi, Pakistan.Study Design: A prospective case series. Period: 04 years duration from January 2013 toDecember 2016. Setting: Tertiary Care Centre in Karachi, Pakistan. Method: All the patientswho were included in the study signed a full informed consent. The inclusion criterion was allthe patients who cervical spine fracture/dislocation, presented to us within 24 hours of injuryand were operated at our set up. Data was collected in a predesigned proforma which includeda complete history and physical examination, age, gender, cause of injury, co morbidities, preoperativeradiological findings, past medical and surgical history. Serial X rays, MRI and CTscans were taken at 3, 6, 12 and 24 months post operatively for evaluation of stability, fusion andany complication such as deformity. The American Spinal Cord Injury Association impairmentscale was utilized in all the patients at follow ups to determine the sensory and motor functionimprovement post operatively. Data was analyzed using IBM SPSS for windows version 21.Results: The study population consisted of n= 40 patients of which n= 28 were male andn= 12 were female with a mean age of 45.2 years. The various types of injuries sustained bythe patients were as follows, n= 6 (15%) cases of cases had compression fractures (vertical),n=15 (37.5%) had flexion rotation injury and n=19 (47.5%) had flexion compression fracturesrespectively. While the division of bony injuries in the patient was as follows, n=5 (12.5%) hadcervical spinal burst fracture with dislocation, n= 15 (37.5%) patients had joint facet fracturewith dislocation bilaterally along with compression fracture of the vertebral body, n= 14 (35%)patients had facet joint fracture with dislocation bilaterally and n= 6 (15%) had unilateral fracturedislocation of joint facet. Complications such as injury to the vertebral artery, spinal cord, nerveroot were not observed in any of the patients in this series, all the patients achieved full bonyfusion at the 6 month follow up as observed on radiographic images. We also did not find anyincidence of screw penetration into the pedicle, similarly no incidence of screw breakage orloosening was observed. N=24 patients with incomplete injury of the spinal cord showedimprovements in their ASIA impairment scale, the patients n= 15 who had a complete spinalcord injury failed to show any improvement post operatively, but reported some decrease in painand numbness post operatively. Conclusion: For fractures/dislocations of the cervical spine thecervical pedicle screw is a reliable and effective method and provides good stability and bonyfusion. However the technique is dependent on surgeons experience and the extensive use ofpre-operative imaging to select the best insertion site of the screws as individualized for everypatient accordingly.
ABSTRACT… Objectives:The aim of our study is to determine the outcome of cervical pedicle screw fixation for fractures/dislocations of the cervical spine at our set up in Karachi, Pakistan. Study Design: A prospective case series. Period: 04 years duration from January 2013 to December 2016. Setting: Tertiary Care Centre in Karachi, Pakistan. Method: All the patients who were included in the study signed a full informed consent. The inclusion criterion was all the patients who cervical spine fracture/dislocation, presented to us within 24 hours of injury and were operated at our set up. Data was collected in a predesigned proforma which included a complete history and physical examination, age, gender, cause of injury, co morbidities, preoperative radiological findings, past medical and surgical history. Serial X rays, MRI and CT scans were taken at 3, 6, 12 and 24 months post operatively for evaluation of stability, fusion and any complication such as deformity. The American Spinal Cord Injury Association impairment scale was utilized in all the patients at follow ups to determine the sensory and motor function improvement post operatively. Data was analyzed using IBM SPSS for windows version 21. Results:The study population consisted of n= 40 patients of which n= 28 were male and n= 12 were female with a mean age of 45.2 years. The various types of injuries sustained by the patients were as follows, n= 6 (15%) cases of cases had compression fractures (vertical), n=15 (37.5%) had flexion rotation injury and n=19 (47.5%) had flexion compression fractures respectively. While the division of bony injuries in the patient was as follows, n=5 (12.5%) had cervical spinal burst fracture with dislocation, n= 15 (37.5%) patients had joint facet fracture with dislocation bilaterally along with compression fracture of the vertebral body, n= 14 (35%) patients had facet joint fracture with dislocation bilaterally and n= 6 (15%) had unilateral fracture dislocation of joint facet. Complications such as injury to the vertebral artery, spinal cord, nerve root were not observed in any of the patients in this series, all the patients achieved full bony fusion at the 6 month follow up as observed on radiographic images. We also did not find any incidence of screw penetration into the pedicle, similarly no incidence of screw breakage or loosening was observed. N=24 patients with incomplete injury of the spinal cord showed improvements in their ASIA impairment scale, the patients n= 15 who had a complete spinal cord injury failed to show any improvement post operatively, but reported some decrease in pain and numbness post operatively. Conclusion: For fractures/dislocations of the cervical spine the cervical pedicle screw is a reliable and effective method and provides good stability and bony fusion. However the technique is dependent on surgeons experience and the extensive use of pre-operative imaging to select the best insertion site of the screws as individualized for every patient accordingly. Key words:Cervical Spine; Dislocati...
Objectives: In this study we analyze and study the effectiveness of pediclescrew and rod fixation for the management of unstable fractures of the thoracolumbar spine.The type of study is a Study Design: Case series. Period: 1.5 year duration from April 2014 toSeptember 2015. Setting: Tertiary Care Centre in Karachi, Pakistan. Materials and methods:N= 35 patients were operated at our institute and included in the study. The inclusion criteriawas all those patients who presented to us with unstable fractures of the thoracolumbar spinevia the accident and emergency department of the hospital, and were operated upon and gavefull informed consent to partake in the research were included in this study. All the patientswere operated under general anesthesia. The short segment fixation with pedicle screw rodfixation using the posterior approach was the technique utilized for treatment. Rehabilitationwas started immediately after the surgical procedure. Data was analyzed using SPSS version23. Results: The study population consisted of n= 35 patients of which n= 25 (71.42%) weremales and n= 10 (28.57%) were females, the mean age of the study population was 33.5years. A history of fall from height was the most common cause of injury in n= 26 (74.28%)of the patients, next was automobile accidents in n= 9 patients (25.71%). Burst fracture wasthe most common type of injury. The sagittal angle was 23.5O pre operatively and 10.75 O postoperatively, and at follow up the loss of angle was found to be 4.80 respectively. The sagittalindex values were as follows, pre-operative 0.53, post-operative 0.75 and 0.72 at follow up (finalfollow up). N= 30 (85.71%) patients showed improvement in their ASIA status, n= 19 (54.28%)showed single grade improvement, n= 10 (28.57%) showed double grade improvement, n=1 (2.85%) showed triple grade improvement, while n= 5 (14.28%) cases did not show anyimprovement. The mean duration between injury and surgical intervention was 5.5 days witha range of 1 to 23 days, the major cause of this delay was delay in reaching the hospital. Themost common complication observed was pressure sores in n= 4 (11.42%) and urinary tractinfections (UTI) seen in n= 5 (14.28%) of patients, followed by implant failure in n=3 (8.57%)patients. Conclusion: According to the results of our study unstable burst fractures was themost prevalent type of fracture observed, there was a marked improvement in the radiologicalparameters post operatively, while the neurological improvement was decent. The technique ofpedicle screw rod and fixation using the posterior approach provides good surgical outcomeand better stabilization, with a fair amount of neurological improvement for these patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.