The use of vibration monitors is a well-established practice in industrial maintenance, usually vibration sensors are positioned at specific points on the monitored machinery and data are continuously collected to feed a machine operating health control system. Nevertheless, the technology for obtaining the signal, its treatment and analysis is generally expensive, and the financial return is not evident, which justifies the development of low-cost alternatives technologies. In this work was performed an analysis of the responses of two Micro-Electro-Mechanical accelerometers, models ADXL345 and MPU6050, exposed to a low intensity random signal and standard operating frequency. The objective of the analysis was to verify the capacity of these devices to be used as mechanical vibration sensors for rotating machines. For this purpose, offset shift analyzes of the sensors due to the Earth's gravitational field were performed, as well as vibrational spectrum and rectification errors analysis under multiple conditions. The data pointed to a greater uniformity of the MPU6050 response, while several behavioral anomalies were seen in the ADXL345, when these sensors are exposed to the same mechanical signal. The qualitative and quantitative behavior of MPU6050 rectification error was consistent with reported in the literature. It was noted that the methodology used can profile the behavior of sensors, however, it is not sufficient to safely justify the inaccuracies, requiring that the tests be performed on a statistically representative number of sensors from different manufacturers and batches.
Os estudantes da Rede Federal de Educação Profissional, Científica e Tecnológica, mesmo geralmente ingressando após processos seletivos concorridos, também enfrentam dificuldades para manterem um bom desempenho. Estudos no campo, com destaque aos de Felder e Silverman, apontam que parte significativa disso se relaciona diretamente com os estilos de aprendizagem, que são padrões comportamentais individuais que podem implicar em maior ou menor facilidade para aprender determinado assunto. O presente estudo apresenta os resultados de uma investigação que buscou identificar influências de estilos de aprendizagem de professor e estudantes sobre o desempenho escolar, levando-se em consideração também os métodos didáticos utilizados. O contexto analisado foi o do Curso Técnico Integrado em Edificações do IFMG Campus Santa Luzia, especificamente nas disciplinas de Estabilidade das Construções e Matemática. A metodologia consistiu fundamentalmente na aplicação de questionário adaptado ao contexto brasileiro para caracterização dos estilos a estudantes e professores. Dentre os resultados, destaca-se que os melhores desempenhos estiveram mais ligados a estilos mais flexíveis dos estudantes do que a uma convergência em relação ao estilo do professor.
ResumoObjetivos: Este trabalho teve como objetivo principal a obtenção de dados de pequenos campos de raios X que evidenciassem as hipóteses apontadas como dificultadoras para a dosimetria destes. Foi realizada a verificação da compatibilidade entre o limite do campo dosimétrico com o campo geométrico e a verificação da relação kerma-dose segundo o esperado para campos convencionais. Materiais e Métodos: Simulações computacionais de campos menores que 5x5 cm² foram realizadas utilizando o método de Monte Carlo por meio da aplicação egs_chamber, esta derivada do código de transporte de radiação EGSnrc. Como fontes de partículas, foram utilizados phase space files de um modelo de cabeçote do acelerador linear CLINAC 2100 acoplado a cones de Radiocirurgia Estereotáxica. Resultados: As simulações sugeriram a existência de um patamar, próximo de 8%, nas discrepâncias entre o FWHM da Dose e o diâmetro nominal do campo, indicando um decréscimo destes valores para campos de diâmetros menores que 12 mm e maiores que 36 mm. Simultaneamente, as discrepâncias dose-kerma em profundidade atingiram valores superiores a 14% no caso onde o fenômeno foi mais significativo. Conclusão: Os dados da relação kerma-dose mostraram que, de fato, o comportamento dos pequenos campos destoa daquele esperado para campos convencionais, e que as convenções dosimétricas tradicionais não se aplicam a tais campos, sendo necessária uma abordagem especializada para as técnicas que os empregam. Além disto, a existência do já referido patamar de discrepâncias, juntamente com a diminuição destas em campos de diâmetro menor que 15 mm, constituem um achado notável. Palavras-chave: Pequenos Campos, Dosimetria, Monte Carlo, EGSnrcAbstract Objectives: This work aimed to obtain data from small fields of X-rays that evidence of the hypotheses cited as cause of difficulties for the dosimetry of these. For this purpose, the verification of compatibility between the dosimetric boundary of field and the geometric size of field, was performed. Also, the verification of kerma dose according to the expected relationship for conventional fields was made. Materials and Methods: Computer simulations of smaller fields 5x5 cm² were performed, using the Monte Carlo method by egs_chamber application, this derived from EGSnrc radiation transport code. As particulate sources were used phase space files of a Clinac 2100 head model coupled to cones Stereotactic Radiosurgery. Results: The simulations suggested the existence of a plateau in discrepancies between the dose FWHM and the nominal diameter of the field close to 8%. These simulations also indicated a decrease of these values for fields with diameters smaller than 12 mm and larger than 36 mm. Simultaneously, the dose kerma differences in depth reached values higher than 14% in the case where the phenomenon is more significant. Conclusion: The data showed that in fact the behavior of small fields clashes with that expected for conventional fields, and that the traditional dosimetric conventions do not apply to such field...
RESUMONeste trabalho foi empregado o Método de Monte Carlo para a simulação de campos clínicos de radioterapia que serão posteriormente utilizados para a calibração de pequenos campos de radiocirurgia. O código de transporte de radiação utilizado foi o NRC's electron gamma shower (EGSnrc) e seus derivados, BEAMnrc e DOSXYZnrc, empregados para a construção e simulação do acelerador e objeto simulador de água, respectivamente. Foram simulados três campos de fótons quadrados com dimensões de 4x4 cm², 10x10 cm² e 20x20 cm², todos com energias nominais de 6 MeV. Os resultados foram comparados com valores experimentais obtidos na rotina de calibração e dosimetria do acelerador real que foi modelado. Para simulações foram utilizadas 10 9 histórias, PCUT=0,01 MeV e ECUT = 0,7 MeV. A máxima incerteza relativa encontrada nas regiões de interesse foi de 4%. A concordância do dimensionamento lateral dos campos manteve-se em níveis superiores a 98% enquanto as doses em profundidade, no pior dos casos, apresentaram concordância superior a 96%. Embora precisem ser tratadas com cuidado, as imprecisões detectadas no processo de simulação são inerentes ao método de simulação empregado, o que, aliado a seus valores permitiram que o modelo fosse considerado válido para aplicações futuras.Palavras-chave: Radioterpia, Monte Calo, EGSnrc
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.