BackgroundDecreasing anastomotic leak rates remain a major goal in colorectal surgery. Assessing intraoperative perfusion by indocyanine green (ICG) with near‐infrared (NIR) visualization may assist in selection of intestinal transection level and subsequent anastomotic vascular sufficiency. This study examined the use of NIR‐ICG imaging in colorectal surgery.MethodsThis was a prospective phase II study (NCT02459405) of non‐selected patients undergoing any elective colorectal operation with anastomosis over a 3‐year interval in three tertiary hospitals. A standard protocol was followed to assess NIR‐ICG perfusion before and after anastomosis construction in comparison with standard operator visual assessment alone.ResultsFive hundred and four patients (median age 64 years, 279 men) having surgery for neoplastic (330) and benign (174) pathology were studied. Some 425 operations (85·3 per cent) were started laparoscopically, with a conversion rate of 5·9 per cent. In all, 220 patients (43·7 per cent) underwent high anterior resection or reversal of Hartmann's operation, and 90 (17·9 per cent) low anterior resection. ICG angiography was achieved in every patient, with a median interval of 29 s to visualization of the signal after injection. NIR‐ICG assessment resulted in a change in the site of bowel division in 29 patients (5·8 per cent) with no subsequent leaks in these patients. Leak rates were 2·4 per cent overall (12 of 504), 2·6 per cent for colorectal anastomoses and 3 per cent for low anterior resection. When NIR‐ICG imaging was used, the anastomotic leak rates were lower than those in the participating centres from over 1000 similar operations performed with identical technique but without NIR‐ICG technology.ConclusionRoutine NIR‐ICG assessment in patients undergoing elective colorectal surgery is feasible. NIR‐ICG use may change intraoperative decisions, which may lead to a reduction in anastomotic leak rates.
Background and aims Anastomotic dehiscence is one of the most feared complications in colorectal surgery leading to significant morbidity and mortality. Progressively lower anastomoses are associated with a greater leak rate. One of the key factors is the perfusion of the bowel to be joined. Presently, surgeons rely on a variety subjective measures to determine anastomotic perfusion and mechanical integrity however these have shortcomings. The aim of this paper is to appraise the literature on the use of fluorescence angiography (FA) in laparoscopic rectal surgery.
We report a good outcome in three patients after endoscopically assisted ELAPE. This approach allows the patient to be operated on in the lithotomy position giving excellent views of the anterior dissection.
BackgroundStandard surgical practice for colorectal cancer involves resection of the primary lesion and all draining lymph nodes. Accurate intraoperative assessment of nodal status could allow stratified resectional extent. One-step nucleic acid (OSNA) can provide a rapid method of interrogating nodal tissue, whilst near-infrared (NIR) laparoscopy together with indocyanine green (ICG) can identify relevant nodal tissue intraoperatively.MethodsICG was administered around the tumour endoscopically prior to the operation. Fluorescent nodes identified by NIR were marked and submitted for whole-node OSNA analysis. Further fresh lymph nodes dissected from the standard resection specimen were examined and analysed by both conventional histology and OSNA. In addition, the status of the fluorescent nodes was compared to that of non-ICG nodes to assess their predictive value.ResultsSixteen patients were recruited with a total final lymph node count of 287. 78 fresh lymph nodes were identified on fresh dissection for both histological and OSNA assessment with an analytical concordance rate of 98.7% (77/78). OSNA sensitivity was 1 (0.81–1, 95% CI) and specificity 0.98 (0.91–1, 95% CI). Six patients had a total of nine nodes identified intraoperatively by ICG fluorescence. Of these nine nodes, one was positive for metastasis on OSNA. OSNA analysis of the ICG-labelled node matched the final histological nodal stage in 3/6 patients (two being N0 and one N1). The final pathological nodal stage of the other three was N1 or N2, while the ICG nodes were negative.ConclusionOSNA is highly concordant with standard histology, although only a minority of nodes identifiable by full pathological analysis were found for OSNA on fresh dissection. OSNA can be combined with NIR and ICG lymphatic mapping to provide intraoperative assessment of nodal tissue in patients with colorectal cancer.
The Acute Physiology And Chronic Health Evaluation II score might be helpful in predicting the need for relaparotomies in patients with secondary peritonitis of colorectal origin.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.