A new, compact UCLH Mk 2.5 EIT system has been developed and calibrated for EIT imaging of the head. Improvements include increased input and output impedances, increased bandwidth and improved CMRR (80 dB) and linearity over frequencies and load (0.2% on a single channel, +/-0.7% on a saline tank over 20 Hz-256 kHz and 10-65 Omega). The accuracy of the system is sufficient to image severe acute stroke according to the specification from recent detailed anatomical modelling (Horesh et al 2005 3rd European Medical and Biological Engineering Conference EMBEC'05). A preliminary human study has validated the main specifications of the modelling, the range of trans-impedance from the head (8-70 Omega) using a 32 electrode, 258 combination protocol and contact impedances of 300 Omega to 2.7 kOmega over 20 Hz to 256 kHz.
MFEIT (multi-frequency electrical impedance tomography) could distinguish between ischaemic and haemorrhagic stroke and permit the urgent use of thrombolytic drugs in patients with ischaemic stroke. The purpose of this study was to characterize the UCLH Mk 2 MFEIT system, designed for this purpose, with 32 electrodes and a multiplexed 2 kHz to 1.6 MHz single impedance measuring circuit. Data were collected in seven subjects with brain tumours, arteriovenous malformations or chronic stroke, as these resembled the changes in haemorrhagic or ischaemic stroke. Calibration studies indicated that the reliable bandwidth was only 16-64 kHz because of front-end components placed to permit simultaneous EEG recording. In raw in-phase component data, the SD of 16-64 kHz data for one electrode combination across subjects was 2.45 +/- 0.9%, compared to a largest predicted change of 0.35% estimated using the FEM of the head. Using newly developed methods of examining the most sensitive channels from the FEM, and nonlinear imaging constrained to the known site of the lesion, no reproducible changes between pathologies were observed. This study has identified a specification for accuracy in EITS in acute stroke, identified the size of variability in relation to this in human recordings, and presents new methods for analysis of data. Although no reproducible changes were identified, we hope this will provide a foundation for future studies in this demanding but potentially powerful novel application.
The use of realistic anatomy in the model used for image reconstruction in EIT of brain function appears to confer significant improvements compared to geometric shapes such as a sphere. Accurate model geometry may be achieved by numerical models based on magnetic resonance images (MRIs) of the head, and this group has elected to use finite element meshing (FEM) as it enables detailed internal anatomy to be modelled and has the capability to incorporate information about tissue anisotropy. In this paper a method for generating accurate FEMs of the human head is presented where MRI images are manually segmented using custom adaptation of industry standard commercial design software packages. This is illustrated with example surface models and meshes from adult epilepsy patients, a neonatal baby and a phantom latex tank incorporating a real skull. Mesh quality is assessed in terms of element stretch and hence distortion.
Electrical impedance tomography (EIT) is a recently developed medical imaging method which has practical advantages for imaging brain function as it is inexpensive, rapid and portable. Its principal use in validated human studies to date has been to image changes in impedance at a single excitation frequency over time, but there are potential applications where it is desirable to obtain images from a single point in time, which could be achieved by imaging over multiple frequencies. We describe a novel multifrequency EIT design which provides up to 64 electrodes for imaging in the head. This was achieved by adding a multiplexer to a single channel of an existing system, the Sheffield Mark 3.5. This provides a flexible protocol for addressing up to 64 electrodes but CMRR decreases from 90 dB to 80 dB and analogue amplifier bandwidth from > 1.6 MHz to 0.8 MHz. This did not significantly affect performance, as cylinders of banana, 10% of the diameter of a saline filled spherical tank, could be visualized with frequency referenced imaging. The design appears to have been an acceptable compromise between practicality and performance and will now be employed in clinical trials of multifrequency EIT in stroke, epilepsy and neonatal brain injury.
The UCLH Mark 1b is a portable EIT system that can address up to 64 electrodes, which has been designed for imaging brain function with scalp electrodes. It employs a single impedance-measuring circuit and multiplexer so that electrode combinations may be addressed flexibly using software. It operates in the relatively low frequency band between 225 Hz and 77 kHz, as lower frequencies produce larger changes during brain activity, and has a videocassette-sized headbox on a lead 10 m long, connected to a base box the size of a video recorder, and notebook PC, so that recordings may be made in ambulant subjects. Its performance was assessed using a resistor-capacitor network, and two saline-filled tanks-a cylindrical Perspex one and a latex one which contained a human skull. System signal-to-noise ratio was better than 50 dB and the maximum reciprocity error less than 10% for most frequencies. The CMMR was better than 80 dB at 38 kHz and a sponge, 20 mm across, which caused a local 12% impedance increase, was correctly localized in images. This suggests that the system has adequate performance to image impedance changes of 5-50% known to occur in the brain during normal activity, epilepsy or stroke; clinical trials to image these conditions are in progress.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.