BackgroundBioelectrical impedance vector analysis (BIVA) is a general concept that includes all methodologies used in the analysis of the bioelectrical vector, whereas the "classic" BIVA is a patented methodology included among these methods of analysis. Once this was clarified, the systematic review of the literature provides a deeper insight into the scope and range of application of BIVA in sport and exercise.ObjectiveThe main goal of this work was to systematically review the sources on the applications of BIVA in sport and exercise and to examine its usefulness and suitability as a technique for the evaluation of body composition, hydration status, and other physiological and clinical relevant characteristics, ultimately to trace future perspectives in this growing area, including a proposal for a research agenda.MethodsSystematic literature searches in PubMed, SPORTDiscus and Scopus databases up to July, 2017 were conducted on any empirical investigations using phase-sensitive bioimpedance instruments to perform BIVA within exercise and sport contexts. The search included healthy sedentary individuals, physically active subjects and athletes.ResultNineteen eligible papers were included and classified as sixteen original articles and three scientific conference communications. Three studies analysed short-term variations in the hydration status evoked by exercise/training through whole-body measurements, eleven assessed whole-body body composition changes induced by long-term exercise, four compared athletic groups or populations using the whole-body assessment, and two analysed bioelectrical patterns of athletic injuries or muscle damage through localised bioimpedance measurements.ConclusionsBIVA is a relatively new technique that has potential in sport and exercise, especially for the assessment of soft-tissue injury. On the other hand, the current tolerance ellipses of “classic” BIVA are not a valid method to identify dehydration in individual athletes and a new approach is needed. “Specific” BIVA, a method which proposes a correction of bioelectrical values for body geometry, emerges as the key to overcome “classic” BIVA limitations regarding the body composition assessment. Further research establishing standardised testing procedures and investigating the relationship between physiology and the bioelectrical signal in sport and exercise is needed.
This paper addresses the design, simulation, manufacturing, and experimental test of textile dipole antennas based on advanced embroidery techniques. The proposed dipoles are intended to operate at the 2.45 GHz industrial scientific and medical radio band for wireless body area network applications. Two medium stitch density embroidery patterns have been studied, satin fill and contour fill, implemented according to the ISO 4915:1991 301 stitch type standard. The impact and viability of these embroidery techniques over the dipole performance in cotton and felt textile substrates are reported. Test results confirm notable antenna parameter results in terms of return loss, radiation pattern, realized gain, and efficiency. In particular, contour pattern has been revealed as the best embroidery manufacturing technique in terms of quality factor and losses, whereas the satin pattern fits the resonance frequency of the antenna with a higher degree of accuracy.
In this work, two embroidered textile moisture sensors are characterized with three different conductive yarns. The sensors are based on a capacitive interdigitated structure embroidered on a cotton substrate with an embroidered conductor yarn. The performance comparison of three different type of conductive yarns has been addressed. In order to evaluate the sensor sensitivity, the impedance of the sensor has been measured by means of an LCR meter from 20 Hz to 20 kHz on a climatic chamber with a sweep of the relative humidity from 30% to 65% at 20 °C. The experimental results show a clear and controllable dependence of the sensor impedance with the relative humidity and the chosen conductor yarns. This dependence points out the optimum conductive yarn to be used to develop wearable applications for moisture measurement.
This review paper summarizes various approaches developed in the literature for antenna sensors with an emphasis on flexible solutions. The survey helps to recognize the limitations and advantages of this technology. Furthermore, it offers an overview of the main points for the development and design of flexible antenna sensors from the selection of the materials to the framing of the antenna including the different scenario applications. With regard to wearable antenna sensors deployment, a review of the textile materials that have been employed is also presented. Several examples related to human body applications of flexible antenna sensors such as the detection of NaCl and sugar solutions, blood and bodily variables such as temperature, strain, and finger postures are also presented. Future investigation directions and research challenges are proposed.
In this work, an embroidered textile moisture sensor is presented. The sensor is based on a capacitive interdigitated structure embroidered on a cotton substrate with an embroidery conductor yarn composed of 99% pure silver plated nylon yarn 140/17 dtex. In order to evaluate the sensor sensitivity, the impedance of the sensor has been measured by means of a impedance meter (LCR) from 20 Hz to 20 kHz in a climatic chamber with a sweep of the relative humidity from 25% to 65% at 20 °C. The experimental results show a clear and controllable dependence of the sensor impedance with the relative humidity. Moreover, the reproducibility of the sensor performance subject to the manufacturing process variability and washing process is also evaluated. The results show that the manufacturing variability introduces a moisture measurement error up to 4%. The washing process impact on the sensor behavior after applying the first washing cycle implies a sensitivity reduction higher than 14%. Despite these effects, the textile sensor keeps its functionality and can be reused in standard conditions. Therefore, these properties point out the usefulness of the proposed sensor to develop wearable applications within the health and fitness scope including when the user needs to have a life cycle longer than one-time use.
In this paper, the utilization of common fabrics for the manufacturing of e-textile metamaterial transmission lines is investigated. In order to filter and control the signal propagation in the ultra-high frequency (UHF) range along the e-textile, a conventional metamaterial transmission line was compared with embroidered metamaterial particles. The proposed design was based on a transmission line loaded with one or several split-ring resonators (SRR) on a felt substrate. To explore the relations between physical parameters and filter performance characteristics, theoretical models based on transmission matrices’ description of the filter constituent components were proposed. Excellent agreement between theoretical prediction, electromagnetic simulations, and measurement were found. Experimental results showed stop-band levels higher than −30 dB for compact embroidered metamaterial e-textiles. The validated results confirmed embroidery as a useful technique to obtain customized electromagnetic properties, such as filtering, on wearable applications.
Measuring electrical activity in the human body is vital in the diagnosis and monitoring of patients; thus, attention to the design of biopotential electrodes is essential. It is important that electrodes are designed accordingly by adapting to a specific device and application. By embroidering electrodes, we can tailor the electrode parameters to suit the application and integrate them into textile outfits. However, embroidered electrodes possess unwanted polarizing impedance () relative to the frequency of the current applied by the system. Dry embroidered electrodes are preferred to wet electrodes for bioelectrical impedance analysis (BIA) recordings providing stable measurements. BIA is a relatively simple and non-invasive technique that measures the resistivity of biological tissue. This research analyzes the impact of embroidery characteristics (i.e. electrode surface area, stitch type, stitch density and stitch length) on embroidered electrodes by identifying the parameters reducing for BIA in a dry and wet state. In addition, the influence of the amount of conductive thread utilised for the fabrication of the sample electrodes was studied. For dry electrodes, we identified that a larger electrode surface area, increased stitch length and stitch density reduce . Moreover, it was observed that potentially there is a threshold on the amount of conductive yarn used for the embroidered electrode. In contrary, wet electrodes displayed irregular and thus, it can be concluded that they could potentially impair BIA measurements. In essence, our findings show that embroidered electrodes can be incorporated into wearable BIA systems for health monitoring in home settings.
Textile radio-frequency identification operating in ultra-high frequency (UHF-RFID) sensors based on different scenarios are becoming attractive with the forthcoming internet of things (IoT) era and aging society. Compared with conventional UHF-RFID sensors, textile UHF-RFID sensors offer the common textile features, light weight, washability and comfort. Due to the short time and low level of development, researches on the integration of textile UHF-RFID techniques and textile sensing techniques are not flourishing. This paper is motivated by this situation to identify the current research status. In this paper, we provide a systematic review of the fundamentals of textile UHF-RFID sensors techniques, materials, the brief history and the state-of-the-art of the scenario-based development through detailed summary and analysis on the achievements from the starting year of 2004 to the present time. Moreover, according to the analysis, we give a proposal of the future prospects in several aspects, including the new materials and manufacturing processes, machine learning technology, scenario-based applications and unavoidable reliability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.