This paper proposes a diagnosis method which exploits the information delivered by external flux sensors placed in the vicinity of rotating electrical machines, in order to detect a stator inter-turn short circuit. This fault induces a dissymmetry in the external magnetic field that can be measured by the sensors. Sensitive harmonics are extracted from the signals delivered by a pair of sensors placed at 180° from each other around the machine and data obtained for several sensor positions are analyzed by fusion techniques using the belief function theory. The diagnosis method is applied on induction and synchronous machines with artificial stator faults. It will be shown that one can obtain high probability to detect the fault using the proposed fusion technique: on various series of measurements, the proposed approach has obtained a 90% detection rate on a considered machine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.