Acquisition of leptospirosis during recreational activities also occurs in resource rich countries and might be even more common than occupational acquisition; diagnosis seems to be frequently missed due to the disease's multifaceted clinical presentation and insufficient awareness of caregivers.
Background: Suboptimal device programming is among the reasons for reduced response to cardiac resynchronization therapy (CRT). However, whether systematic optimization is beneficial remains unclear, particularly late after CRT implantation. The aim of this singlecenter cohort study was to assess the effect of systematic atrioventricular delay (AVD) optimization on echocardiographic and device parameters. Methods: Patients undergoing CRT optimization at the University Hospital Zurich between March 2011 and January 2013, for whom a follow-up was available, were included. AVD optimization was based on 12-lead electrocardiography (ECG) and echocardiographic left ventricular inflow characteristics. Parameters were assessed at the time of CRT optimization and follow-up, and were compared between patients with AVD optimization (intervention group) and those for whom no AVD optimization was deemed necessary (control group). Results: Eighty-one patients with a mean age of 64 ± 11 years were included in the analysis. In 73% of patients, AVD was deemed suboptimal and was changed accordingly. After a median follow-up time of 10.4 (IQR 6.2 to 13.2) months, the proportion of patients with sufficient biventricular pacing (> 97% pacing) was greater in the intervention group (78%) compared to controls (50%). Furthermore, AVD adaptation was associated with an improvement in interventricular mechanical delay (decrease of 6.6 ± 26.2 ms vs. increase of 4.3 ± 17.7 ms, p = 0.034) and intraventricular septal-to-lateral delay (decrease of 0.9 ± 48.1 ms vs. increase of 15.9 ± 15.7 ms, p = 0.038), as assessed by tissue Doppler imaging. Accordingly, a reduction was observed in mitral regurgitation along with a trend towards reduced left ventricular volumes. Conclusions: In this "real-world" setting systematic AVD optimization was associated with beneficial effects regarding biventricular pacing and left ventricular remodeling. These data show that AVD optimization may be advantageous in selected CRT patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.