BackgroundSimple and inexpensive non-invasive fibrosis tests are highly needed but have been poorly studied in sub-Saharan Africa.MethodsUsing liver histology as a gold standard, we developed a novel index using routine laboratory tests to predict significant fibrosis in patients with chronic HBV infection in The Gambia, West Africa. We prospectively assessed the diagnostic accuracy of the novel index, Fibroscan, aspartate transaminase-to-platelet ratio index (APRI), and Fib-4 in Gambian patients with CHB (training set) and also in French and Senegalese CHB cohorts (validation sets).ResultsOf 135 consecutive treatment-naïve patients with CHB who had liver biopsy, 39% had significant fibrosis (Metavir fibrosis stage ≥F2) and 15% had cirrhosis (F4). In multivariable analysis, gamma-glutamyl transpeptidase (GGT) and platelet count were independent predictors of significant fibrosis. Consequently, GGT-to-platelet ratio (GPR) was developed. In The Gambia, the area under the receiver operating characteristic curve (AUROC) of the GPR was significantly higher than that of APRI and Fib-4 to predict ≥F2, ≥F3 and F4. In Senegal, the AUROC of GPR was significantly better than Fib-4 and APRI for ≥F2 (0.73, 95% CI 0.59 to 0.86) and better than Fib-4 and Fibroscan for ≥F3 (0.93, 0.87 to 0.99). In France, the AUROC of GPR to diagnose ≥F2 (0.72, 95% CI 0.59 to 0.85) and F4 (0.87, 0.76 to 0.98) was equivalent to that of APRI and Fib-4.ConclusionsThe GPR is a more accurate routine laboratory marker than APRI and Fib-4 to stage liver fibrosis in patients with CHB in West Africa. The GPR represents a simple and inexpensive alternative to liver biopsy and Fibroscan in sub-Saharan Africa.
Background The natural history of chronic HBV infection in sub-Saharan Africa is unknown. Data are required to inform WHO guidelines that are currently based on studies in Europe and Asia. Methods Between 1974 and 2008, serosurveys were repeated in two Gambian villages, and an open cohort of treatment-naive chronic HBV carriers was recruited. Participants were followed to estimate the rates of hepatitis B e (HBeAg) and surface antigen (HBsAg) clearance and incidence of hepatocellular carcinoma (HCC). In 2012–2013, a comprehensive liver assessment was conducted to estimate the prevalence of severe liver disease. Results 405 chronic carriers (95% genotype E), recruited at a median age of 10.8 years, were followed for a median length of 28.4 years. Annually, 7.4% (95% CI 6.3% to 8.8%) cleared HBeAg and 1.0% (0.8% to 1.2%) cleared HBsAg. The incidence of HCC was 55.5/100 000 carrier-years (95% CI 24.9 to 123.5). In the 2012–2013 survey (n=301), 5.5% (95% CI 3.4% to 9.0%) had significant liver fibrosis. HBV genotype A (versus E), chronic aflatoxin B1 exposure and an HBsAg-positive mother, a proxy for mother-to-infant transmission, were risk factors for liver fibrosis. A small proportion (16.0%) of chronic carriers were infected via mother-to-infant transmission; however, this population represented a large proportion (63.0%) of the cases requiring antiviral therapy. Conclusions The incidence of HCC among chronic HBV carriers in West Africa was higher than that in Europe but lower than rates in East Asia. High risk of severe liver disease among the few who are infected by their mothers underlines the importance of interrupting perinatal transmission in sub-Saharan Africa
f Hepatitis B virus (HBV) infection is a leading cause of death in sub-Saharan Africa (SSA). Point-of-care tests for hepatitis B surface antigen (HBsAg) could be an ideal tool for a large-scale HBV screening/treatment program in SSA. Using data from the PROLIFICA (Prevention of Liver Fibrosis and Cancer in Africa) program, we conducted a cross-sectional study to assess the diagnostic accuracy of three point-of-care tests (Determine, Vikia, and Espline) for the detection of HBsAg in the field or a laboratory setting in the Gambia. In the field, we used finger-prick whole blood for the Determine and Vikia tests and dried blood spots for the reference standard test (AxSYM HBsAg enzyme-linked immunosorbent assay [ELISA]). In the laboratory we used serum for the Determine, Espline, and reference test (Architect chemiluminescent microparticle immunoassay). Of 773 participants recruited at the community and 227 known chronic HBV carriers (1,000 subjects in total), 293 were positive for HBsAg. The sensitivity and specificity of the Determine test were 88.5% and 100% in the field and 95.3% and 93.3% in the laboratory setting, respectively. The sensitivity and specificity were 90.0% and 99.8% for the Vikia test (in the field) and 93.9% and 94.7% for the Espline test (in the laboratory). There was no evidence that one kit was better than another. Most of the patients with false-negative results (18/19) were classified as inactive chronic carriers. In summary, the three point-of-care tests had acceptable ranges of diagnostic accuracy. These tests may represent accurate, rapid, and inexpensive alternatives to serology testing for the screening of HBV infection at field level in SSA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.