Abstract. At the Izaña Observatory, water vapour amounts have been measured routinely by different techniques for many years. We intercompare the total precipitable water vapour (PWV) amounts measured between 2005 and 2009 by a Fourier Transform Infrared (FTIR) spectrometer, a Multifilter Rotating Shadow-band Radiometer (MFRSR), a Cimel sunphotometer, a Global Positioning System (GPS) receiver, and daily radiosondes (Vaisala RS92). The long-term characteristics of our study allows a reliable and extensive empirical quality assessment of long-term validity, which is an important prerequisite when applying the data to climate research. We estimate a PWV precision of 1% for the FTIR, about 10% for the MFRSR, Cimel, and GPS (when excluding rather dry conditions), and significantly better than 15% for the RS92 (the detection of different airmasses avoids a better constrained estimation). We show that the MFRSR, Cimel and GPS data quality depends on the atmospheric conditions (humid or dry) and that the restriction to clear-sky observations introduces a significant dry bias in the FTIR and Cimel data. In addition, we intercompare the water vapour profiles measured by the FTIR and the Vaisala RS92, which allows the conclusion that both experiments are able to detect lower to upper tropospheric water vapour mixing ratios with a precision of better than 15%.
Abstract. Eddy covariance (EC) flux measurements of the atmosphere/surface exchange of gases over an urban area are a direct way to improve and evaluate emissions inventories, and, in turn, to better understand urban atmospheric chemistry and the role that cities play in regional and global chemical cycles. As part of the MCMA-2003 study, we demonstrated the feasibility of using eddy covariance techniques to measure fluxes of selected volatile organic compounds (VOCs) and CO 2 from a residential district of Mexico City (Velasco et al., 2005a, b). During the MILAGRO/MCMA-2006 field campaign, a second flux measurement study was conducted in a different district of Mexico City to corroborate the 2003 flux measurements, to expand the number of species measured, and to obtain additional data for evaluation of the local emissions inventory. Fluxes of CO 2 and olefins were measured by the conventional EC technique using an open path CO 2 sensor and a Fast Isoprene Sensor calibrated with a propylene standard. In addition, fluxes of toluene, benzene, methanol and C 2 -benzenes were measured using a virtual disjunct EC method with a Proton Transfer Reaction Mass Spectrometer. The flux measurements were analyzed in terms of diurnal patterns and vehicular activity and were compared with the most recent gridded local emissions inventory. In both studies, the results showed that the urban surface of Mexico City is a net source of CO 2 and VOCs with significant contributions from vehicular traffic. EvapCorrespondence to: E. Velasco (evelasco@mce2.org) orative emissions from commercial and other anthropogenic activities were significant sources of toluene and methanol. The results show that the emissions inventory is in reasonable agreement with measured olefin and CO 2 fluxes, while C 2 -benzenes and toluene emissions from evaporative sources are overestimated in the inventory. It appears that methanol emissions from mobile sources occur, but are not reported in the mobile emissions inventory.
Abstract. Surface pollutant concentrations in México Cityshow a distinct pattern of weekly variations similar to that observed in many other cities of the world. Measurements of the concentrations of carbon monoxide (CO), nitrogen oxides (NO x =NO+NO 2 ), particulate matter smaller than 10 µm (PM 10 ), and ozone (O 3 ) collected hourly over 22 years at 39 urban monitoring locations were analyzed. Morning concentrations of CO, NO x , and PM 10 are lower on Saturdays and even more so on Sundays, compared to workdays (Monday-Friday), while afternoon O 3 concentrations change minimally and are occasionally even higher. This weekend effect is empirical evidence that photochemical O 3 production is NO x -inhibited, and to the extent that emissions of CO are proportional to those of reactive volatile organic compounds (VOCs), it is VOC-limited, at least in the urban areas for which the monitoring stations are representative. The VOC-limitation has increased in the past decade, due to decreases in the concentrations of CO (and presumably VOCs) and consequent decreases in the CO/NO x and VOC/NO x ratios. Enhancements of photolysis frequencies resulting from smaller weekend aerosol burdens are not negligible, but fall short of being an alternate explanation for the observed weekend effect. The strength of the weekend effect indicates that local radical termination occurs primarily via formation of nitric acid and other NO x -related compounds, some of which (e.g. peroxy acyl nitrates) can contribute to the regional NO x budget. While VOC emission reductions would be most effective in reducing local O 3 production, NO x emission reduction may be more important for controlling regional oxidants.
Abstract. MCMA-2003 was a major field campaign investigating the atmospheric chemistry of the Mexico City Metropolitan Area (MCMA) in April of 2003. This paper describes the wind circulation patterns during the campaign both within the Mexico City basin and on the regional scale. ''Time roses'' are introduced to concisely analyze the diurnal wind patterns. Three episode types were identified that explain the conditions encountered: ''O3-South'', ''Cold Surge'' and ''O3-North''. These can be diagnosed from a combination of synoptic and basin observations based on whether the day was predominantly cloudy, or whether the O3 peak was in the north or south of the basin. O3-South days have weak synoptic forcing due to an anti-cyclone over the eastern Pacific. Strong solar heating leads to northerly flows in the basin and an evening shift due to a gap flow from the south-east. Peak ozone concentrations are in the convergence zone in the south of the city. Cold Surge days are associated with ''El Norte'' events, with strong surface northerlies bringing cold moist air and rain. Stable conditions lead to high concentrations of primary pollutants and peak ozone in the city center. O3-North days occur when the sub-tropical jet is closer to Mexico City. With strong westerlies aloft, the circulation pattern is the same as O3-South days except for a wind shift in the mid-afternoon leading to ozone peaks in the north of the city. This classification is proposed as a means of understanding pollutant transport in the Mexico City basin and as a basis for future meteorological and chemical analysis. Furthermore, model evaluation and design of policy recommendations will need to take into account the three episode types.
Abstract. The project MUSICA (MUlti-platform remote Sensing of Isotopologues for investigating the Cycle of Atmospheric water) integrates tropospheric water vapour isotopologue remote sensing and in situ observations. This paper presents a first empirical validation of MUSICA's H 2 O and δD remote sensing products, generated from groundbased FTIR (Fourier transform infrared), spectrometer and space-based IASI (infrared atmospheric sounding interferometer) observation. The study is made in the area of the Canary Islands in the subtropical northern Atlantic. As reference we use well calibrated in situ measurements made aboard an aircraft (between 200 and 6800 m a.s.l.) by the dedicated ISOWAT instrument and on the island of Tenerife at two different altitudes (at Izaña, 2370 m a.s.l., and at Teide, 3550 m a.s.l.) by two commercial Picarro L2120-i water isotopologue analysers.The comparison to the ISOWAT profile measurements shows that the remote sensors can well capture the variations in the water vapour isotopologues, and the scatter with respect to the in situ references suggests a δD random uncertainty for the FTIR product of much better than 45 ‰ in the lower troposphere and of about 15 ‰ for the middle troposphere. For the middle tropospheric IASI δD product the study suggests a respective uncertainty of about 15 ‰. In both remote sensing data sets we find a positive δD bias of 30-70 ‰.Complementing H 2 O observations with δD data allows moisture transport studies that are not possible with H 2 O observations alone. We are able to qualitatively demonstrate the added value of the MUSICA δD remote sensing data. We document that the δD-H 2 O curves obtained from the different in situ and remote sensing data sets (ISOWAT, Picarro at Izaña and Teide, FTIR, and IASI) consistently identify two different moisture transport pathways to the subtropical north eastern Atlantic free troposphere.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.