Background: Robotic exoskeleton (RE) based gait training involves repetitive task-oriented movements and weight shifts to promote functional recovery. To effectively understand the neuromuscular alterations occurring due to hemiplegia as well as due to the utilization of RE in acute stroke, there is a need for electromyography (EMG) techniques that not only quantify the intensity of muscle activations but also quantify and compare activation timings in different gait training environments.Purpose: To examine the applicability of a novel EMG analysis technique, Burst Duration Similarity Index (BDSI) during a single session of inpatient gait training in RE and during traditional overground gait training for individuals with acute stroke.Methods: Surface EMG was collected bilaterally with and without the RE device for five participants with acute stroke during the normalized gait cycle to measure lower limb muscle activations. EMG outcomes included integrated EMG (iEMG) calculated from the root-mean-square profiles, and a novel measure, BDSI derived from activation timing comparisons.Results: EMG data demonstrated volitional although varied levels of muscle activations on the affected and unaffected limbs, during gait with and without the RE. During the stance phase mean iEMG of the soleus (p = 0.019) and rectus femoris (RF) (p = 0.017) on the affected side significantly decreased with RE, as compared to without the RE. The differences in mean BDSI scores on the affected side with RE were significantly higher than without RE for the vastus lateralis (VL) (p = 0.010) and RF (p = 0.019).Conclusions: A traditional amplitude analysis (iEMG) and a novel timing analysis (BDSI) techniques were presented to assess the neuromuscular adaptations resulting in lower extremities muscles during RE assisted hemiplegic gait post acute stroke. The RE gait training environment allowed participants with hemiplegia post acute stroke to preserve their volitional neuromuscular activations during gait iEMG and BDSI analyses showed that the neuromuscular changes occurring in the RE environment were characterized by correctly timed amplitude and temporal adaptations. As a result of these adaptations, VL and RF on the affected side closely matched the activation patterns of healthy gait. Preliminary EMG data suggests that the RE provides an effective gait training environment for in acute stroke rehabilitation.
The data suggests that our AB individuals experienced reduction in walking velocity and muscle activation amplitudes while walking in the exoskeleton and moreover with voluntary control there is a greater temporal-spatial response of the lower limbs. Also, there are neuromuscular phasic adaptions for both AB and SCI groups while walking in the exoskeleton that are inconsistent to non-EXO gait muscle activation.
The goal of this paper is to demonstrate a novel approach that combines Empirical Mode Decomposition (EMD) with Notch filtering to remove the electrical stimulation (ES) artifact from surface electromyogram (EMG) data for interpretation of muscle responses during functional electrical stimulation (FES) experiments. FES was applied to the rectus femoris (RF) muscle unilaterally of six able bodied (AB) and one individual with spinal cord injury (SCI). Each trial consisted of three repetitions of ES. We hypothesized that the EMD algorithm provides a suitable platform for decomposing the EMG signal into physically meaningful intrinsic mode functions (IMFs) which can be further used to isolate electrical stimulation (ES) artifact. A basic EMD algorithm was used to decompose the EMG signals collected during FES into IMFs for each repetition separately. IMFs most contaminated by ES were identified based on the standard deviation (SD) of each IMF. Each artifact IMF was Notch filtered to filter ES harmonics and added to remaining IMFs containing pure EMG data to get a version of a filtered EMG signal. Of all such versions of filtered signals generated from each artifact IMF, the one with maximum signal to noise ratio (SNR) was chosen as the final output. The validity of the filtered signal was assessed by quantitative metrics, 1) root mean squared error (RMSE) and signal to noise (SNR) ratio values obtained by comparing a clean EMG and EMD-Notch filtered signal from the combination of simulated ES and clean EMG and, 2) using EMG-force correlation analysis on the data collected from AB individuals. Finally, the potential applicability of this algorithm on a neurologically impaired population was shown by applying the algorithm on EMG data collected from an individual with SCI. EMD combined with Notch filtering successfully extracted the EMG signal buried under ES artifact. Filtering performance was validated by smaller RMSE values and greater SNR post filtering. The amplitude values of the filtered EMG signal were seen to be consistent for three repetitions of ES and there was no significant difference among the repetition for all subjects. For the individual with a SCI the algorithm was shown to successfully isolate the underlying bursts of muscle activations during FES. The data driven nature of EMD algorithm and its ability to act as a filter bank at different bandwidths make this method extremely suitable for dissecting ES induced EMG into IMFs. Such IMFs clearly show the presence of ES artifact at different intensities as well as pure artifact free EMG. This allows the application of Notch filters to IMFs containing ES artifact to further isolate the EMG. As a result of such stepwise approach, the extraction of EMG is achieved with minimal data loss. This study provides a unique approach to dissect and interpret the EMG signal during FES applications.
BackgroundA foot drop stimulator (FDS) is a rehabilitation intervention that stimulates the common peroneal nerve to facilitate ankle dorsiflexion at the appropriate time during post-stroke hemiplegic gait. Time–frequency analysis (TFA) of non-stationary surface electromyograms (EMG) and spectral variables such as instantaneous mean frequency (IMNF) can provide valuable information on the long-term effects of FDS intervention in terms of changes in the motor unit (MU) recruitment during gait, secondary to improved dorsiflexion.ObjectiveThe aim of this study was to apply a wavelet-based TFA approach to assess the changes in neuromuscular activation of the tibialis anterior (TA), soleus (SOL), and gastrocnemius (GA) muscles after utilization of an FDS during gait post-stroke.MethodsSurface EMG were collected bilaterally from the TA, SOL, and GA muscles from six participants (142.9 ± 103.3 months post-stroke) while walking without the FDS at baseline and 6 months post-FDS utilization. Continuous wavelet transform was performed to get the averaged time–frequency distribution of band pass filtered (20–300 Hz) EMGs during multiple walking trials. IMNFs were computed during normalized gait and were averaged during the stance and swing phases. Percent changes in the energies associated with each frequency band of 25 Hz between 25 and 300 Hz were computed and compared between visits.ResultsAveraged time–frequency representations of the affected TA, SOL, and GA EMG show altered spectral attributes post-FDS utilization during normalized gait. The mean IMNF values for the affected TA were significantly lower than the unaffected TA at baseline (p = 0.026) and follow-up (p = 0.038) during normalized stance. The mean IMNF values significantly increased (p = 0.017) for the affected GA at follow-up during normalized swing. The frequency band of 250–275 Hz significantly increased in the energies post-FDS utilization for all muscles.ConclusionThe application of wavelet-based TFA of EMG and outcome measures (IMNF, energy) extracted from the time–frequency distributions suggest alterations in MU recruitment strategies after the use of FDS in individuals with chronic stroke. This further establishes the efficacy of FDS as a rehabilitation intervention that may promote motor recovery in addition to treating the secondary complications of foot drop due to post-stroke hemiplegia.
BACKGROUND Functional Electrical Stimulation (FES) applied through a foot drop stimulator (FDS) is a rehabilitation intervention that can stimulate the common peroneal nerve to provide dorsiflexion at the correct timing during gait. OBJECTIVE To determine if FES applied to the peroneal nerve during walking through a FDS would effectively retrain the electromyographic temporal activation of the tibialis anterior in individuals with stroke. METHODS Surface electromyography (EMG) were collected bilaterally from the tibialis anterior (TA) while participants (n = 4) walked with and without the FDS at baseline and 4 weeks. Comparisons were made between stimulation timing and EMG activation timing to produce a burst duration similarity index (BDSI). RESULTS At baseline, participants displayed variable temporal activation of the TA. At 4 weeks, TA activation during walking without the FDS more closely resembled the pre-programmed FDS timing demonstrated by an increase in BDSI scores in all participants (P = 0.05). CONCLUSIONS Continuous use of FDS during a task specific movement can re-train the neuromuscular system. After 4 weeks of utilization the FDS trained the TA to replicate the programmed temporal activation patterns. These findings begin to establish the FDS as a rehabilitation intervention that may facilitate recovery rather than just compensate for stroke related gait impairments due to foot drop.
Surface electromyography (sEMG) is a widely used technology in rehabilitation research and provides quantifiable information on the myoelectric output of a muscle. In this perspective, we discuss the barriers which have restricted the wide-spread use of sEMG in clinical rehabilitation of individuals with spinal cord injury (SCI). One of the major obstacles is integrating the time-consuming aspects of sEMG in the already demanding schedule of physical therapists, occupational therapists, and other clinicians. From the clinicians' perspective, the lack of confidence to use sEMG technology is also apparent due to their limited exposure to the sEMG technology and possibly limited mathematical foundation through educational and professional curricula. Several technical challenges include the limited technology-transfer of ever-evolving knowledge from sEMG research into the off-the-shelf EMG systems, lack of demand from the clinicians for systems with advanced features, lack of user-friendly intuitive interfaces, and the need for a multidisciplinary approach for accurate handling and interpretation of data. We also discuss the challenges in the application and interpretation of sEMG that are specific to SCI, which are characterized by non-standardized approaches in recording and interpretation of EMGs due to the physiological and structural state of the spinal cord. Addressing the current barriers will require a collaborative, interdisciplinary, and unified approach. The most relevant steps could include enhancing user-experience for students pursuing clinical education through revised curricula through sEMG-based case studies/projects, hands-on involvement in the research, and formation of a common platform for clinicians and technicians for self-education and knowledge share.
Rectification of surface EMGs during electrical stimulations (ES) is still a problem to be solved. The broad band frequency components of ES artifact overlap with the EMG spectrum, make this task challenging. In this study, we investigate the potential use of empirical mode decomposition (EMD) method to remove the stimulus artifact from surface EMGs collected during such applications. We hypothesize that the EMD algorithm provides a suitable platform for decomposing the EMG signal into physically meaningful intrinsic modes which can be used to isolate ES artifact. Basic EMD is tested on two signals - ES induced EMG and EMG of voluntary contractions added with simulated ES signal. The algorithm isolates the EMG from ES artifact with considerable success. Further, the EMD method along with the energy operator -TKEO gives even better representation of the EMG signal. However, some high frequency data was lost during reconstruction process. Hence, there is further need to investigate the relationship between the EMD parameters and stimulus artifact properties so that the algorithm can be optimized to reconstruct pure artifact free EMG signal with minimum lost of data.
For the last 40 years, actigraphy or wearable accelerometry has provided an objective, low-burden and ecologically valid approach to assess real-world sleep and circadian patterns, contributing valuable data to epidemiological and clinical insights on sleep and sleep disorders. The proper use of wearable technology in sleep research requires validated algorithms that can derive sleep outcomes from the sensor data. Since the publication of the first automated scoring algorithm by Webster in 1982, a variety of sleep algorithms have been developed and contributed to sleep research, including many recent ones that leverage machine learning and / or deep learning approaches. However, it remains unclear how these algorithms compare to each other on the same data set and if these modern data science approaches improve the analytical validity of sleep outcomes based on wrist-worn acceleration data. This work provides a systematic evaluation across 8 state-of-the-art sleep algorithms on a common sleep data set with polysomnography (PSG) as ground truth. Despite the inclusion of recently published complex algorithms, simple regression-based and heuristic algorithms demonstrated slightly superior performance in sleep-wake classification and sleep outcome estimation. The performance of complex machine learning and deep learning models seem to suffer from poor generalization. This independent and systematic analytical validation of sleep algorithms provides key evidence on the use of wearable digital health technologies for sleep research and care.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.