This review provides a path to achieve economic, safe, and energy-efficient graphene composites as anode materials for high-energy sodium-ion batteries.
In this work, the optimization study of the solar collector integrated, with a thermal energy storage tank for the vapor absorption refrigeration system, was studied using TRNSYS. The performance of the integrated system was evaluated considering major contributing parameters such as solar collector area, the mass flow rate of the operating fluids, storage tank volume and height, absorber plate thickness, tube spacing, absorber tube diameter, insulation thickness, and glass thickness/properties, respectively. A physical model of the complete solar water heating (SWH) and refrigeration system was developed followed by simulation studies of the major components for optimization, and finally, the obtained results were compared with the reported data for validation. The results indicated that, by using the solar power with a serpentine tube type flat plate collector of area 24 m2 and a storage volume to a specific collector area of about 60 Lm−2, the optimized system could meet 65% of the annual thermal energy requirement for the refrigeration unit. Further, the annual performance of the optimized solar collector in terms of collector efficiency, heat removal factor, and overall heat loss coefficient was found to be about 0.32, 0.87, and 2.99 W m−2 K, respectively. In addition, the optimization approach that is adopted using TRNSYS in the present study could be used for optimizing the solar‐based energy system for various applications.
In this work, the experimental investigation on the performance and exergy analysis of mobile air conditioning system with suction line heat exchanger using environmental friendly HFO-1234yf was carried out under varied evaporator air flow rates. The performance was compared with existing HFC-134a results. The performance analysis showed that the cooling capacity and the coefficient of performance of the system with HFO-1234yf were lower than that of the HFC-134a by upto 2–11%. The power consumption and the volumetric efficiency of the compressor with HFO-1234yf were found to be 14.02% and 11.2% higher than that of HFC-134a. From the exergy analysis, it was observed that the major exergy destruction occurred in the compressor, followed by the condenser, evaporator, thermostatic expansion valve, and suction line heat exchanger for both refrigerants. The exergy efficiency of the system with HFO-1234yf was 2.4–12.6% lower than that of HFC-134a. From this study, it was observed that the losses experienced in the compressor, thermostatic expansion valve and evaporator lead to poor performance with HFO-1234yf.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.