Objectives: To detect possible severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) RNA contamination of inanimate surfaces in areas at high risk of aerosol formation by patients with coronavirus disease 2019 (COVID-19). Methods: Sampling was performed in the emergency unit and the sub-intensive care ward. SARS-CoV-2 RNA was extracted from swabbed surfaces and objects and subjected to real-time RT-PCR targeting RNAdependent RNA polymerase and E genes. Virus isolation from positive samples was attempted in vitro on Vero E6 cells. Results: Twenty-six samples were collected and only two were positive for low-level SARS-CoV-2 RNA, both collected on the external surface of continuous positive airway pressure helmets. All transport media were inoculated onto susceptible cells, but none induced a cytopathic effect on day 7 of culture. Conclusions: Even though daily contact with inanimate surfaces and patient fomites in contaminated areas may be a medium of infection, our data obtained in real-life conditions suggest that it might be less extensive than hitherto recognized.
PSWE is a reproducible method for assessing liver stiffness, and it compares with TE. Compared with patients with nonsignificant fibrosis, healthy volunteers showed significantly lower values.
The results of this study show that the agreement between LSMs performed with different US systems is good to excellent and the overall inter-observer agreement in "ideal conditions" is above 0.90 in expert hands.
Abstract. Knowledge of variables influencing serology is crucial to evaluate serology results for the diagnosis and clinical management of cystic echinococcosis (CE). We analyzed retrospectively a cohort of patients with hepatic CE followed in our clinic in 2000-2012 to evaluate the influence of several variables on the results of commercial enzymelinked immunosorbent assay (ELISA) and indirect hemagglutination (IHA) tests. Sera from 171 patients with ≥ 1 hepatic CE cyst, and 90 patients with nonparasitic cysts were analyzed. CE cysts were staged according to the WHO-IWGE classification and grouped by activity. A significant difference in ELISA optical density (OD) values and percentage of positivity was found among CE activity groups and with controls (P < 0.001). The serological response was also influenced by age (P < 0.001) and cyst number (P = 0.003). OD values and cyst size were positively correlated in active cysts (P = 0.001). IHA test showed comparable results. When we analyzed the results of 151 patients followed over time, we found that serology results were significantly influenced by cyst activity, size, number, and treatment ≤ 12 months before serum collection. In conclusion, serological responses as assessed by commercial tests depend on CE cyst activity, size and number, and time from treatment. Clinical studies and clinicians in their practice should take this into account.
Reproducibility of SS measurements depends on the expertise of the operator. To achieve good reproducibility between measurements a training period is required. A learning curve in pSWE acquisition should be taken into account. SS measurements are less reproducible than LS measurements.
BackgroundTo assess the clinical validity of controlled attenuation parameter (CAP) in the diagnosis of hepatic steatosis in a series of overweight or obese children by using the imperfect gold standard methodology.MethodsConsecutive children referred to our institution for auxological evaluation or obesity or minor elective surgery were prospectively enrolled. Anthropometric and biochemical parameters were recorded. Ultrasound (US) assessment of steatosis was carried out using ultrasound systems. CAP was obtained with the FibroScan 502 Touch device (Echosens, Paris, France). Pearson’s or Spearman’s rank correlation coefficient were used to test the association between two study variables. Optimal cutoff of CAP for detecting steatosis was 249 dB/m. The diagnostic performance of dichotomized CAP, US, body mass indexes (BMI), fatty liver index (FLI) and hepatic steatosis index (HSI) was analyzed using the imperfect gold standard methodology.ResultsThree hundred five pediatric patients were enrolled. The data of both US and CAP were available for 289 children. Steatosis was detected in 50/289 (17.3%) children by US and in 77/289 (26.6%) by CAP. A moderate to good correlation was detected between CAP and BMI (r = 0.53), FLI (r = 0.55) and HSI (r = 0.56). In obese children a moderate to good correlation between CAP and insulin levels (r = 0.54) and HOMA-IR (r = 0.54) was also found. Dichotomized CAP showed a performance of 0.70 (sensitivity, 0.72 [0.64–0.79]; specificity, 0.98 [0.97–0.98], which was better than that of US (performance, 0.37; sensitivity, 0.46 [0.42–0.50]; specificity, 0.91 [0.89–0.92]), BMI (performance, 0.22; sensitivity, 0.75 [0.73–0.77]; specificity, 0.57 [0.55–0.60]) and FLI or HSI.ConclusionsFor the evaluation of liver steatosis in children CAP performs better than US, which is the most widely used imaging technique for screening patients with a suspicion of liver steatosis. A cutoff value of CAP of 249 dB/m rules in liver steatosis with a very high specificity.
Transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index values were correlated with histologic stages of fibrosis. Transient elastography offered excellent diagnostic performance in assessing severe fibrosis and cirrhosis. Real-time elastography does not yet have the potential to substitute for transient elastography in the assessment of liver fibrosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.