Peripheral nerves are structures that, when damaged, can result in significant motor and sensory disabilities. Several studies have used therapeutic resources with the aim of promoting early nerve regeneration, such as the use of low-power laser. However, this laser therapy does not represent a consensus regarding the methodology, thus yielding controversial conclusions. The objective of our study was to investigate, by functional evaluation, the comparative effects of low-power laser (660 nm and 830 nm) on sciatic nerve regeneration following crushing injuries. Twenty-seven Wistar rats subjected to sciatic nerve injury were divided into three groups: group sham, consisting of rats undergoing simulated irradiation; a group consisting of rats subjected to gallium-aluminum-arsenide (GaAlAs) laser at 660 nm (10 J/cm(2), 30 mW and 0.06 cm(2) beam), and another one consisting of rats subjected to GaAlAs laser at 830 nm (10 J/cm(2), 30 mW and 0.116 cm(2)). Laser was applied to the lesion for 21 days. A sciatic functional index (SFI) was used for functional evaluation prior to surgery and on days 7, 14, and 21 after surgery. Differences in SFI were found between group 660 nm and the other ones at the 14th day. One can observe that laser application at 660 nm with the parameters and methods utilised was effective in promoting early functional recovery, as indicated by the SFI, over the period evaluated.
Peripheral nerve lesions caused sensory and motor deficits along the distribution of the injured nerve. Numerous researches have been carried out to enhance and/or accelerate the recovery of such lesions. The objective of this study was to assess the functional recovery of sciatic nerve in rats subjected to different fluences of low-level laser therapy (LLLT). Thirty-six animals were randomly divided into four groups: one consisting of sham rats and three others irradiated with progressive fluencies of 10 J/cm 2 , 40 J/cm 2 and 80 J/cm 2 of laser AsGaAl (830 nm) for 21 consecutive days. They were evaluated by the Sciatic Functional Index (SFI) method. The crush injury was performed by using a portable device with dead weight of 5,000 g whose load was applied for 10 min. A digital camera was used to record the footprints left on the acrylic track, before surgery and after, on the 7th, 14th, and 21st days. The results also showed that on the 7th day, there was a difference between the groups irradiated with 40 J/cm 2 , when compared with the sham group (p<0.05). On the 14th day the groups irradiated with 40 J/cm 2 and 80 J/cm 2 also presented better results when compared with sham, however, on the 21st day, no inter-group difference was found (p>0.05). It was possible to observe that the LLLT at fluency of 40 J/cm 2 and 80 J/cm 2 had a positive influence on the acceleration of the functional nerve recovery.
Multiple sclerosis (MS) is an autoimmune demyelinating inflammatory disease characterized by recurrent episodes of T cell-mediated immune attack on central nervous system (CNS) myelin, leading to axon damage and progressive disability. The existing therapies for MS are only partially effective and are associated with undesirable side effects. Low-level laser therapy (LLLT) has been clinically used to treat inflammation, and to induce tissue healing and repair processes. However, there are no reports about the effects and mechanisms of LLLT in experimental autoimmune encephalomyelitis (EAE), an established model of MS. Here, we report the effects and underlying mechanisms of action of LLLT (AlGaInP, 660 nm and GaAs, 904 nm) irradiated on the spinal cord during EAE development. EAE was induced in female C57BL/6 mice by immunization with MOG35-55 peptide emulsified in complete Freund's adjuvant. Our results showed that LLLT consistently reduced the clinical score of EAE and delayed the disease onset, and also prevented weight loss induced by immunization. Furthermore, these beneficial effects of LLLT seem to be associated with the down-regulation of NO levels in the CNS, although the treatment with LLLT failed to inhibit lipid peroxidation and restore antioxidant defense during EAE. Finally, histological analysis showed that LLLT blocked neuroinflammation through a reduction of inflammatory cells in the CNS, especially lymphocytes, as well as preventing demyelination in the spinal cord after EAE induction. Together, our results suggest the use of LLLT as a therapeutic application during autoimmune neuroinflammatory responses, such as MS.
BackgroundOutcome after nerve repair of the hand needs standardized psychometrically robust measures. We aimed to systematically review the psychometric properties of available functional, motor, and sensory assessment instruments after nerve repair.MethodsThis systematic review of health measurement instruments searched databases from 1966 to 2017. Pairs of raters conducted data extraction and quality assessment using a structured tool for clinical measurement studies. Kappa correlation was used to define the agreement prior to consensus for individual items, and intraclass correlation coefficient (ICC) was used to assess reliability between raters. A narrative synthesis described quality and content of the evidence.ResultsSixteen studies were included for final critical appraisal scores. Kappa ranged from 0.31 to 0.82 and ICC was 0.81. Motor domain had manual muscle testing with Kappa from 0.72 to 0.93 and a dynamometer ICC reliability between 0.92 and 0.98. Sensory domain had touch threshold Semmes-Weinstein monofilaments (SWM) as the most responsive measure while two-point discrimination (2PD) was the least responsive (effect size 1.2 and 0.1). A stereognosis test, Shape and Texture Identification (STI), had Kappa test-retest reliability of 0.79 and inter-rater reliability of 0.61, with excellent sensibility and specificity. Manual tactile test had moderate to mild correlation with 2PD and SWM. Function domain presented Rosén-Lundborg score with Spearman correlations of 0.83 for total score. Patient-reported outcomes measurements had ICC of 0.85 and internal consistency from 0.88 to 0.96 with Patient-Rated Wrist and Hand Evaluation with higher score for reliability and Spearman correlation between 0.38 and 0.89 for validity.ConclusionsFew studies included nerve repair in their sample for the psychometric analysis of outcome measures, so moderate evidence could be confirmed. Manual muscle test and Rotterdam Intrinsic Hand Myometer dynamometer had excellent reliability but insufficient data on validity or responsiveness. Touch threshold testing was more responsive than 2PD test. The locognosia test and STI had limited but positive supporting data related to validity. Rosén-Lundborg score had emerging evidence of reliability and validity as a comprehensive outcome following nerve repair. Few questionnaires were considered reliable and valid to assess cold intolerance. There is no patient-reported outcome measurement following nerve repair that provides comprehensive assessment of symptoms and function by patient perspective.Electronic supplementary materialThe online version of this article (10.1186/s13643-018-0836-0) contains supplementary material, which is available to authorized users.
To analyze the effect of photobiomodulation and dexamethasone on nerve regeneration after a sciatic nerve crushing model. Twenty-six Swiss mice were divided into the following groups: naive; sham; injured, low-level laser therapy (LLLT) (660 nm, 10 J/cm, 0.6 J, 16.8 J total energy emitted during the 28 days of radiation, 20 s, for 28 days); dexamethasone (Dex) (local injection of 2 mg/kg for 10 consecutive days); and LLLT group associated with Dex (LLLT/Dex), with the same parameters of the other groups. For nerve injury, a portable adjustable pinch was used. The animals were evaluated using the Sciatic Functional Index (SFI) and Sciatic Static Index (SSI). The results obtained were evaluated with Image J™ and Kinovea™. Data and images were obtained at baseline and after 7, 14, 21, and 28 days after surgery. The evaluation of hyperalgesia, using Hargreaves, and behavior through the open field was also performed. In functional and static analysis, all groups presented significant differences when compared to the injured group. In the analysis of the SSI results, the group treated with both LLLT and dexamethasone was more effective in improving the values of this parameter, and in the SFI, the laser-treated group obtained better results. In the evaluation through the open field and the Hargreaves, there was no difference. The application of LLLT and dexamethasone was effective in nerve regeneration according to the results and was more effective when LLLT was associated with dexamethasone than in LLLT alone for the SSI.
Introduction: Movement of the forearm allows positioning the hand during several functional activities of daily living. Assessing range of motion of supination and pronation is essential for clinical identification of functional limitations, although many methods can be used. Confounding values can be found due to different techniques used by therapists. The purpose of this study was to compare two standard goniometric methods for measuring active range of motion of forearm pronation and supination, aiming to define its reliability and ease of use. Methods: The study included 33 individuals, 13 injured and 20 non-injured volunteers. We analyzed two standard goniometric methods for measuring pronation and supination. For the first method, the volunteers had to hold a pencil as a guide for the movable arm of the goniometer and for the second method the movable arm was in contact with the distal dorsal surface of the wrist near the ulna head, and the hand was free. Two trained examiners performed the evaluations. Intraclass correlation coefficient and limits of agreement of Bland and Altman were used to analyze the data. Results: Intraclass correlation coefficient values were excellent for both groups and movements at inter-rater and intermethods comparison. Bland and Altman plots showed that, although excellent reliability, some data dispersion was present. Conclusion: These data suggest that both methods could be used in clinical practice with excellent reliability. The goniometric method with the movable arm placed in contact with the distal dorsal surface of the wrist near the ulna head might be easier to perform and useful in cases where finger prehension is absent or weak, which would prevent the use of a pencil as reference.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.