Glued transscleral fixated IOL can be safely performed in one-eyed patients for specific indications to provide good functional results.
Purpose: To assess the long-term (6-12 years) results and complications of glued transscleral-fixated intraocular lens (IOL). Setting: Dr. Agarwal's Eye Center, Chennai, India. Design: Retrospective case series. Methods: Eyes with glued IOL of more than 5-year follow-up were evaluated. Visual acuity (logarithm of the minimum angle of resolution [logMAR]), IOL tilt, corneal topography, corneal endothelial cell density, intraocular pressure, central corneal thickness, central foveal thickness, and ocular residual astigmatism (ORA) were evaluated. Results: Overall, 91 eyes (63 patients) with mean postoperative 8.2 ± 2.3 years were analyzed. The duration was 10 to 12 years in 31 eyes (34%), 9 years in 14 eyes (15.3%), and 6 to 9 years in 46 eyes (50.5%). No subscleral haptic was visible in 50% eyes. Mild, moderate, and severe grade of haptic visibility was noted in 33.5%, 9.4%, and 7%, respectively. The corrected distance visual acuity (CDVA) was 0.50 ± 0.50 logMAR. Clinically, no tilt was seen in 87 eyes (95.6%), whereas detectable tilt was seen in 4 eyes (4.3%). The optical coherence tomography microtilt was 0.8 ± 1.7 and 0.4 ± 1.2 degrees in 90- and 180-degree axes, respectively. The mean iris vault was 0.45 mm, and the mean ORA was 1.10 ± 1.00 diopter. Complications were glaucoma (7.6%), IOL luxation (4.4%), retinal detachment (3.2%), macular edema (4.3%), corneal decompensation (3.2%), uveitis (2.1%), and uveitis–glaucoma–hyphema syndrome (1%). Haptic reposition (3.2%), retinal detachment surgery (3.2%) keratoplasty (1%), pupilloplasty (2.1%), and IOL explantation (1%) were the second surgeries performed. Conclusions: Glued IOL has shown good anatomical and functional stability with minimal incidence of vision-threatening complications on long-term.
Purpose: To analyze the morphological changes in the iris-knot complex configuration using spectral-domain optical coherence tomography (SD-OCT) following the single pass four throw (SFT) pupilloplasty. Methods: In this retrospective case series, eyes with SFT pupilloplasty were examined by SD-OCT (Optovue). Iris morphology compared to the normal iris, presence of specific patterns (single hump, double humps, peaks and valleys, tethering), prolene suture, knot complex (length and orientation), and intraocular lens (IOL) vault were evaluated. Results: Overall, 41 knots of 26 patients with a mean time duration of 3.1 ± 2 months from surgery were analyzed. Iris configurations seen were single hump ( n = 28, 63.8%), double humps ( n = 7, 17%), loop ( n = 2, 4.8%), flat ( n = 3, 7.3%), and mulberry ( n = 1, 2.4%). The mean length and the height of the knot complex was 784.1 ± 433.7 μm and 317.7 ± 110.4 μm, respectively. Knot positions were at 3 clock hours in 9 eyes (21.9%), 9 in 8 eyes (19.5%), and others in 24 eyes (58.5%). Cut end of the prolene suture was detectable in 26 eyes (63.4%) as hyper-reflective line, and the mean cut length was 465.8 ± 321.1 μm. The suture was predominantly vertically oriented (80.6%) to the iris with a mean distance of 3.6 ± 0.3 mm (2.6–4 mm) away from corneal endothelium. The mean distance from the knot complex and the IOL was 289.2 ± 146 μm and the mean anterior chamber depth was 4.1 ± 0.1 mm. Conclusion: A significant change in iris configuration was noted after SFT pupilloplasty, and vertically oriented retained prolene suture was predominant with good endothelial vault.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.