Climate change is a global emergency. Increasing awareness has led to policy changes regarding global industry emissions. The healthcare industry carbon footprint is large and growing more and more. Gastroenterology, with its heavy reliance on industry, is a major contributor toward this growth. For a significant change toward reducing the field's carbon footprint, it would involve serious industry commitment. At present, there are no clear guidelines or regulations on controlling healthcare-related industry emissions and improving sustainability. This narrative review aims to provide practical suggestions at each step of the supply chain can lead to greater sustainability.
Introduction:
Single-use disposable duodenoscopes (SDD) have been developed to mitigate infectious risks related to reusable duodenoscopes. The aim of this study is to compare the safety and efficacy of the two available SDDs in the United States.
Methods:
We conducted a comparative study of 2 SDD in consecutive ERCP procedures performed by expert endoscopists from 9 academic centers. Performance ratings, procedure details, and adverse events were collected.
Results:
A total of 201 patients were included: 129 patients underwent ERCP with Exalt (mean age 63, Males- 66 (51%), 72 with aScope Duodeno (mean age 65, males=30 (42%). A majority of endoscopists had performed >2000 ERCPs in both groups (71% Exalt, 93% aScope Duodeno). Technical success was 92% in both groups (n=119 Exalt-group, n=66 aScope-Duodeno-group). The procedural complexity for the ERCP cases performed were: Grade 1: 35 cases (18%), Grade 2: 83 cases (41%), Grade 3: 65 cases (32%), and Grade 4: 18 cases (9%). Thirteen patients (10%) from the Exalt group and 16 patients (22%) from the aScope Duodeno group required conversion to a reusable duodenoscope. On a scale of 1 to 5, Exalt and aScope Duodeno, respectively, were rated: 2.31 versus 2.60 for location and visualization quality, 1.38 versus 1.57 for maneuverability based on papillary orientation, 1.48 versus 1.15 for suction/air control, and 2.31 versus 2.34 for elevator efficiency. None of the adverse events were related to the SDDs.
Conclusions:
The 2 SDDs were comparable. Further ongoing enhancements to these devices will improve maneuverability and clinical effectiveness.
Pancreatic fluid collections often develop as a complication of acute pancreatitis but can be seen in a variety of conditions including chronic pancreatitis, trauma, malignancy or post-operatively. It is important to classify a pancreatic fluid collection in order to optimize treatment strategies and management. Most interventions are targeted towards the management of delayed complications of pancreatitis, including pancreatic pseudocysts and walled-off necrosis (WON), which often develop days to weeks after the initial episode of pancreatitis. Surgical, percutaneous, and endoscopic interventions are all possible methods for treatment of pancreatic fluid collections, however endoscopic drainage with endoscopic ultrasound has become first-line. Advances within endoscopic drainage strategies have also led to innovative changes in the specific stents used for treatment, with possible options including double pigtail plastic stents, fully covered self-expanding metal stents and lumen-apposing metal stents (LAMS).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.