Synchrotrons and free-electron lasers are the most powerful sources of X-ray radiation. They constitute invaluable tools for a broad range of research 1 ; however, their dependence on largescale radiofrequency electron accelerators means that only a few of these sources exist worldwide. Laser-driven plasmawave accelerators 2-10 provide markedly increased accelerating fields and hence offer the potential to shrink the size and cost of these X-ray sources to the university-laboratory scale. Here, we demonstrate the generation of soft-X-ray undulator radiation with laser-plasma-accelerated electron beams. The well-collimated beams deliver soft-X-ray pulses with an expected pulse duration of ∼10 fs (inferred from plasma-accelerator physics). Our source draws on a 30-cmlong undulator 11 and a 1.5-cm-long accelerator delivering stable electron beams 10 with energies of ∼210 MeV. The spectrum of the generated undulator radiation typically consists of a main peak centred at a wavelength of ∼18 nm (fundamental), a second peak near ∼9 nm (second harmonic) and a highenergy cutoff at ∼7 nm. Magnetic quadrupole lenses 11 ensure efficient electron-beam transport and demonstrate an enabling technology for reproducible generation of tunable undulator radiation. The source is scalable to shorter wavelengths by increasing the electron energy. Our results open the prospect of tunable, brilliant, ultrashort-pulsed X-ray sources for small-scale laboratories.Resolving the structure and dynamics of matter on the atomic scale requires a probe with ångstrøm resolution in space and femtosecond to attosecond resolution in time. Third-generation synchrotron sources produce X-ray pulses with durations of typically a few tens of picoseconds and can achieve 100 fs by using complex beam-manipulation techniques 12,13 . They have already proven their capability of imaging static structures with atomic (spatial) resolution 1 and upcoming X-ray free-electron lasers hold promise for also extending the temporal resolution into the atomic/sub-atomic range [14][15][16][17][18] . Both of these sources consist of an electron accelerator and an undulator, which is a periodic magnetic structure that forces the electrons to oscillate and emit radiation 19 . Whereas current facilities require a kilometre-scale accelerator, new laser-plasma accelerators offer the potential for a marked reduction in size and cost as well as pulse durations of a few femtoseconds.Femtosecond-laser-driven plasma accelerators have produced quasi-monoenergetic electron beams 2-7 with energies up to 1 GeV (refs 8, 9, 20, 21) from centimetre-scale interaction lengths. The concept is based on an ultra-intense laser pulse, which ionizes atoms of a gas target and excites a plasma wave. This trails the pulse at 1 Max-Planck-Institut für Quantenoptik, Hans-Kopfermann-Str. 1, 85748 Garching, Germany, 2 Department für Physik, Ludwig-Maximilians-Universität, Am Coulombwall 1, 85748 Garching, Germany, 3 Forschungszentrum Dresden-Rossendorf, Bautzner Landstraße 128, 01328 Dresden, Germany, 4 ...
A recent breakthrough in laser-plasma accelerators, based upon ultrashort high-intensity lasers, demonstrated the generation of quasi-monoenergetic GeV-electrons. With future Petawatt lasers ultra-high beam currents of ∼ 100 kA in ∼ 10 fs can be expected, allowing for drastic reduction in the undulator length of free-electron-lasers (FELs). We present a discussion of the key aspects of a table-top FEL design, including energy loss and chirps induced by space-charge and wakefields. These effects become important for an optimized table-top FEL operation. A first proof-of-principle VUV case is considered as well as a table-top X-ray-FEL which may open a brilliant light source also for new ways in clinical diagnostics.
Using quadrupole scan measurements we show laser-wakefield accelerated electrons to have a normalized transverse emittance of 0:21 þ0:01 À0:02 mm mrad at 245 MeV. We demonstrate a multishot and a single-shot method, the mean emittance values for both methods agree well. A simple model of the beam dynamics in the plasma density downramp at the accelerator exit matches the source size and divergence values inferred from the measurement. In the energy range of 245 to 300 MeV the normalized emittance remains constant.Laser-wakefield acceleration (LWFA) [1,2] can deliver ultrarelativistic electron beams in a compact setup with unique features [3][4][5][6]. It is receiving particular attention as a source or driver for ultrashort x-ray beams [7,8] and for its potential for realizing a tabletop free-electron laser (FEL) [9]. The electron bunch duration has recently been measured to be only a few femtoseconds long [10,11] which results in peak beam currents on the order of kiloamperes. An essential parameter for the performance of x-ray sources, FELs, or linear colliders is the transverse electron beam emittance. Previous emittance measurements of LWFA electron beams have used the pepperpot method [12][13][14] giving normalized emittances of $2:2 mm mrad with single shots down to the resolution limit of 1:1 mm mrad. As these measurements are not spectrally resolved, they rely on a low energy spread to give a meaningful normalized emittance. For LWFA beams which fluctuate in energy and energy spread, a simultaneous measurement of the spectrum is required. This technique is also limited to electron energies that can be sufficiently scattered by the pepper-pot mask; to date, measurements of a 508 MeV beam have been carried out [15]. Experiments characterizing the betatron radiation emitted by the electron beam while it is in the plasma suggest the beam size there to be & 1 m [16,17], which in combination with a divergence measurement give an estimated emittance of <0:5 mm mrad [18]. However, inferring the emittance from the electron beam size in the plasma and its downstream divergence in the vacuum can be unreliable as this neglects the plasma-vacuum density transition at the accelerator exit; here the decreasing strength of the plasma focusing forces result in an increase in beam size and decrease in divergence [13]. This publication reports on direct measurements of the emittance of LWFA electrons that are both energy resolved and that include the beam transport of the density downramp at the accelerator exit. This is achieved by analyzing their beam size around a focus using a quadrupole lens scan method [19].The transverse phase space of an electron beam is often specified using the Twiss parameters , , , and the natural emittance ". These parameters describe the volume and orientation of the particle distribution in phase space. The beam size at a particular position ðs 1 Þ is related to the Twiss parameters at s 0 by [20] ðs 1 Þ 2 ¼ M 2 11 ðs 0 Þ À2M 11 M 12 ðs 0 Þþ M 2 12 ðs 0 Þ: (1)Here M ij refers to the ij eleme...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.