Summary Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79). Interpretation In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws. Funding National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
Background Although self‐expandable metal stent (SEMS) placement as bridge to surgery (BTS) in patients with left‐sided obstructing colonic cancer has shown promising short‐term results, it is used infrequently owing to uncertainty about its oncological safety. This population study compared long‐term oncological outcomes between emergency resection and SEMS placement as BTS. Methods Through a national collaborative research project, long‐term outcome data were collected for all patients who underwent resection for left‐sided obstructing colonic cancer between 2009 and 2016 in 75 Dutch hospitals. Patients were identified from the Dutch Colorectal Audit database. SEMS as BTS was compared with emergency resection in the curative setting after 1 : 2 propensity score matching. Results Some 222 patients who had a stent placed were matched to 444 who underwent emergency resection. The overall SEMS‐related perforation rate was 7·7 per cent (17 of 222). Three‐year locoregional recurrence rates after SEMS insertion and emergency resection were 11·4 and 13·6 per cent (P = 0·457), disease‐free survival rates were 58·8 and 52·6 per cent (P = 0·175), and overall survival rates were 74·0 and 68·3 per cent (P = 0·231), respectively. SEMS placement resulted in significantly fewer permanent stomas (23·9 versus 45·3 per cent; P < 0·001), especially in elderly patients (29·0 versus 57·9 per cent; P < 0·001). For patients in the SEMS group with or without perforation, 3‐year locoregional recurrence rates were 18 and 11·0 per cent (P = 0·432), disease‐free survival rates were 49 and 59·6 per cent (P = 0·717), and overall survival rates 61 and 75·1 per cent (P = 0·529), respectively. Conclusion Overall, SEMS as BTS seems an oncologically safe alternative to emergency resection with fewer permanent stomas. Nevertheless, the risk of SEMS‐related perforation, as well as permanent stoma, might influence shared decision‐making for individual patients.
Preliminary results of laparoscopic sentinel node identification using a near-infrared dye show this procedure is safe and feasible. It was possible to detect lymph nodes in all patients. Large tumor size, drainage to adjacent lymphatic vessels, and the use of a rigid needle might contribute to false-negative nodes.
A case of a complicated postoperative course after laparoscopic cholecystectomy in which, ultimately, gallbladder duplication was suspected and confirmed at laparotomy is described. The diagnostic tools, differential diagnosis, and therapy are discussed. After open cholecystectomy patients' complaints dissolved. Awareness of the possibility of a double gallbladder in case of persisting symptoms after laparoscopic cholecystectomy can lead to diagnosis of this condition at an earlier stage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.