At the first peak, KAM is a reasonable substitute for the medial contact force, but not at the second peak. First peak KFM is also a significant contributor to the medial KCF. At the first peak, walking with a modified gait reduced the ratio of the medial to total KCF but not the medial KCF itself. To determine the effects of gait modifications on cartilage loading and disease progression, longitudinal studies and individualized modeling, accounting for motion control, would be required.
Real-time biofeedback directly on the knee adduction moment is a promising option for encouraging gait modifications to reduce knee loading, however only when combined with specific instructions on how to modify the gait.
BackgroundGait retraining interventions using real-time biofeedback have been proposed to alter the loading across the knee joint in patients with knee osteoarthritis. Despite the demonstrated benefits of these conservative treatments, their clinical adoption is currently obstructed by the high complexity, spatial demands, and cost of optical motion capture systems. In this study we propose and evaluate a wearable visual feedback system for gait retraining of the foot progression angle (FPA).MethodsThe primary components of the system are inertial measurement units, which track the human movement without spatial limitations, and an augmented reality headset used to project the visual feedback in the visual field. The adapted gait protocol contained five different target angles ranging from 15 degrees toe-out to 5 degrees toe-in. Eleven healthy participants walked on an instrumented treadmill, and the protocol was performed using both an established laboratory visual feedback driven by optical motion capture, and the proposed wearable system.Results and conclusionsThe wearable system tracked FPA with an accuracy of 2.4 degrees RMS and ICC=0.94 across all target angles and subjects, when compared to an optical motion capture reference. In addition, the effectiveness of the biofeedback, reflected by the number of steps with FPA value ±2 degrees from the target, was found to be around 50% in both wearable and laboratory approaches. These findings demonstrate that retraining of the FPA using wearable inertial sensing and visual feedback is feasible with effectiveness matching closely an established laboratory method. The proposed wearable setup may reduce the complexity of gait retraining applications and facilitate their transfer to routine clinical practice.
In recent years exoskeletons able to replicate human gait have begun to attract growing popularity for both assistive and rehabilitative purposes. Although wearable robots often need the use of external support in order to maintain stability, the REX exoskeleton by REX Bionics is able to self-balance through the whole cycle. However this statically balanced gait presents important differences with the dynamically balanced gait of human subjects. This paper will examine kinematic and kinetic differences between the gait analysis performed on a subject wearing the REX exoskeleton and human gait analysis data as presented in literature. We will also provide an insight on the impact that these differences can have for both rehabilitative and assistive applications.
To evaluate muscle activation patterns and co-contraction around the knee in response to walking with modified gait patterns in patients with medial compartment kneeosteoarthritis (KOA). Design: 40 medial KOA patients walked on an instrumented treadmill. Surface EMG activity from seven knee-spanning muscles (gastrocnemius, hamstrings, quadriceps), kinematics, and ground reaction forces were recorded. Patients received real-time visual feedback on target kinematics to modify their gait pattern towards three different gait modifications: Toe-in, Wider steps, Medial Thrust. The individualized feedback aimed to reduce their first peak knee adduction moment (KAM) by ≥10%. Changes in muscle activations and medial/lateral co-contraction index during the loading response phase (10-35% of the gait cycle) were evaluated, for the steps in which ≥10% KAM reduction was achieved. Results: Data from 30 patients were included in the analyses; i.e. all who could successfully reduce their KAM in a sufficient number of steps by ≥10%. When walking with ≥10% KAM reduction, Medial Thrust gait (KAM −31%) showed increased flexor activation (24%), co-contraction (17%) and knee flexion moment (35%). Isolated wider-step gait also reduced the KAM (−26%), but to a smaller extent, but without increasing muscle activation amplitudes and co-contraction. Toe-in gait showed the greatest reduction in the KAM (−35%), but was accompanied by an increased flexor activation of 42% and hence an increased co-contraction index. Conclusion: Gait modifications that are most effective in reducing the KAM also yield an increase in co-contraction, thereby compromising at least part of the effects on net knee load.
The objective of the present study was to discover if dimensional measurements of the ear could be determined with a laser scanning technique and whether or not the location of landmarks of the ear could be reliably measured with respect to those on the midline of the face. Computer-generated images were created from laser scans of 20 subjects. Dimensional measurements were made between landmarks on the ear and face. Differences between repeated dimensional measurements of the ear were very small, as were those measurements made between landmarks on the ear to the midline of the face. Differences between dimensions of the left and right ears were observed, but were of a small magnitude. The results suggest that the dimensions of the ear and its position with respect to landmarks in the midline of the face can be reliably measured on normal subjects and that laser scanning is a useful technique for planning and monitoring facial reconstruction of the ear.
The objective of this study was to investigate the learning process of knee osteoarthritis (KOA) patients learning to change their foot progression angle (FPA) over a six-week toe-in gait training program. Sixteen patients with medial KOA completed a six-week toe-in gait training program with real-time biofeedback. Patients walked on an instrumented treadmill while receiving real-time feedback on their foot progression angle (FPA) with reference to a target angle. The FPA difference (difference between target and actual FPA) was analyzed during i) natural walking, ii) walking with feedback, iii) walking without feedback and iv) walking with a dual-task at the start and end of the training program. Self-reported difficulty and abnormality and time spent walking and training were also analyzed. The FPA difference during natural walking was significantly decreased from median 6.9 to median 3.6° i.e. by 3.3° in week six (p < 0.001); adding feedback reduced FPA difference to almost zero. However the dual-task condition increased the FPA difference at week one compared to the feedback condition (median difference: 1.8°, p = 0.022), but after training this effect was minimized (median difference: 0.6°, p = 0.167). Self-reported abnormality and difficulty decreased from median 5 to 3 and from median 6 to 3 on the NRS respectively (p < 0.05). Patients with medial KOA could reduce the FPA difference during natural walking after the gait retraining program, with some evidence of a reduction in the cognitive demand needed to achieve this. Automation of adaptions might need support from more permanent feedback using wearable technologies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.