Assessment of cardiac output is an important part of the management of patients with pulmonary hypertension. The accuracy of the thermodilution technique in patients with low cardiac output or severe tricuspid regurgitation has been questioned. To address this issue, we simultaneously compared 105 cardiac output measurements by the Fick method and thermodilution in 35 patients with pulmonary hypertension. Moreover, we evaluated the acetylene rebreathing technique, a noninvasive method of determining cardiac output. The mean difference +/- 95% limit of agreement between thermodilution and the Fick method was +0.01 +/- 1.1 L/min. The mean difference +/- 95% limit of agreement between acetylene rebreathing and the Fick method was -0.23 +/- 1.14 L/min. Neither the mean agreement nor the 95% limits of agreement of both thermodilution and acetylene rebreathing with the Fick method were affected by the presence of low cardiac output or severe tricuspid regurgitation. We conclude that thermodilution and acetylene rebreathing are useful tools for assessing cardiac output in patients with pulmonary hypertension, even in the presence of low cardiac output or severe tricuspid regurgitation.
There is a close relationship between natriuretic peptides and diastolic Doppler parameters of left ventricular filling in patients with dilated cardiomyopathy. There is also a significant difference between patients with mild and severe functional impairment regarding both natriuretic peptides and transmitral Doppler parameters.
Objective-To investigate the diastolic Doppler filling pattern in patients with idiopathic dilated cardiomyopathy and its relation to N-terminal pro-atrial natriuretic peptide (NT-pro-ANP). Methods-32 patients (26 male, six female) with idiopathic dilated cardiomyopathy were investigated. All were in sinus rhythm. Conventional M mode echocardiography and Doppler echocardiography was done in each patient. Pulsed wave Doppler inflow signals were obtained and the following variables were measured: maximum E wave, maximum A wave, E/A ratio, E wave deceleration time, A wave deceleration time. NT-pro-ANP was measured using radioimmunoassay. (Heart 1999;82:630-633)
Results-Mean
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.