The effect of different surface treatments on flux penetration and dissipation at 50 Hz in bulk niobium samples has been quantitatively investigated. It is shown that for a sufficiently smooth sample surface the onset of a.c. dissipation occurs when the peak applied magnetic field exceeds Hc1+ΔH, in striking contrast to earlier results. A comparison of experimental results with a generalized critical-state model yields good agreement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.