Background and purpose: During radiotherapy, prostate motion changes over time. Quantifying and accounting for this motion is essential. This study aimed to assess intra-fraction prostate motion and derive duration-dependent planning margins for two treatment techniques. Material and methods: A four-dimension (4D) transperineal ultrasound Clarity® system was used to track prostate motion. We analysed 1913 fractions from 60 patients undergoing volumetric-modulated arc therapy (VMAT) to the prostate. The mean VMAT treatment duration was 3.4 min. Extended monitoring was conducted weekly to simulate motion during intensity-modulated radiation therapy (IMRT) treatment (an additional seven minutes). A motion-time trend analysis was conducted and the mean intra-fraction motion between VMAT and IMRT treatments compared. Duration-dependent margins were calculated and anisotropic margins for VMAT and IMRT treatments were derived. Results: There were statistically significant differences in the mean intra-fraction motion between VMAT and the simulated IMRT duration in the inferior (0.1 mm versus 0.3 mm) and posterior (−0.2 versus −0.4 mm) directions respectively (p ≪ 0.01). An intra-fraction motion trend inferiorly and posteriorly was observed. The recommended minimum anisotropic margins are 1.7 mm/2.7 mm (superior/inferior); 0.8 mm (left/right), 1.7 mm/2.9 mm (anterior/posterior) for VMAT treatments and 2.9 mm/4.3 mm (superior/inferior), 1.5 mm (left/right), 2.8 mm/4.8 mm (anterior/posterior) for IMRT treatments. Smaller anisotropic margins were required for VMAT compared to IMRT (differences ranging from 1.2 to 1.6 mm superiorly/inferiorly, 0.7 mm laterally and 1.1-1.9 mm anteriorly/posteriorly). Conclusions: VMAT treatment is preferred over IMRT as prostate motion increases with time. Larger margins should be employed in the inferior and posterior directions for both treatment durations. Duration-dependent margins should be applied in the presence of prolonged imaging and verification time.
BackgroundTo derive and exploit the optimal prescription isodose level (PIL) in inverse optimization of volumetric modulated arc radiotherapy (VMAT) as a potential approach to dose de–escalation in stereotactic body radiotherapy for non–small cell lung carcinomas (NSCLC).MethodsFor ten patients, inverse Monte Carlo dose optimization was performed to cover 95% PTV by varying prescription isodose lines (PIL) at 60 to 80% and reference 85%. Subsequently, these were re–normalized to the median gross tumor volume dose (GTV–based prescription) to assess the impacts of PTV and normal tissue dose reduction.ResultsWith PTV–based prescription, GTV mean dose was much higher with the optimized PIL at 60% with significant reduction of normal lung receiving 30 to 10 Gy (V30–10Gy), and observable but insignificant dose reduction to spinal cord, esophagus, ribs, and others compared with 85% PIL. Mean doses to the normal lung between PTV and GTV was higher with 60–70% PIL than 85%. The dose gradient index was 5.0 ± 1.1 and 6.1 ± 1.4 for 60 and 85% PIL (p < 0.05), respectively. Compared with the reference 85% PIL plan using PTV–base prescription, significant decreases of all normal tissue doses were observed with 60% and 70% PIL by GTV–based prescription. Yet, the resulting biological effective (BED) mean doses of PTV remain sufficiently high, ranging 104.2 to 116.9 Gy α/β = 10.ConclusionsOptimizing the PIL with VMAT has notable advantage of improving the dosimetric quality of lung SBRT and offers the potential of dose de–escalation for surrounding tissues while increasing the GTV dose simultaneously. The clinical implication of re–normalizing plans from PTV–prescription at 60–70% to the GTV median dose requires further investigations.
Background and purpose: Inconsistent bladder and rectal volumes have been associated with motion uncertainties during prostate radiotherapy. This study investigates the impact of these volumes to determine the optimal bladder volume. Materials and methods: 60 patients from two Asian hospitals were recruited prospectively. 1887 daily cone-beam computed tomography (CBCT) images were analysed. Intra-fraction motion of the prostate was monitored real-time using a four-dimension transperineal ultrasound (4D TPUS) Clarity Ò system. The impact of planned bladder volume, adequacy of daily bladder filling, and rectum volume on mean intra-fraction motion of the prostate was analysed. Patients' ability to comply with the full bladder hydration protocol and level of frustration was assessed using a questionaire. Acute side effects were assessed using the Common Terminology Criteria for Adverse Events (CTCAE) version 3.0 and quality of life (QoL) assessed using the International Prostate Symptom Score (IPSS). Results: The mean (SD) bladder and rectum volumes achieved during daily treatment were 139.7 cm 3 (82.4 cm 3) and 53.3 cm 3 (18 cm 3) respectively. Mean (SD) percentage change from planned CT volumes in bladder volume was reduced by 8.2% (48.7%) and rectum volume was increased by 12.4% (42.2%). Linear Mixed effect model analysis revealed a reduction in intra-fraction motion in both the Sup/Inf (p = 0.008) and Ant/Post (p = 0.0001) directions when the daily bladder was filled between 82 and 113% (3rd Quartiles) of the planned CT volumes. A reduction in intra-fraction motion of the prostate in the Ant/Post direction (z-plane) (p = 0.03) was observed when the planned bladder volume was greater than 200 ml. Patients complied well with the hydration protocol with minimal frustration (mean (SD) scores of 2.1 (1.4) and 1.8 (1.2) respectively). There was a moderate positive correlation (0.496) between mean bladder volume and IPSS reported post-treatment urinary straining (p = 0.001). Conclusions: A planned bladder volume >200 cm 3 and daily filling between 82 and 113%, reduced intrafraction motion of the prostate. The hydration protocol was well tolerated.
Treating lung tumors with CyberKnife through continuous tracking of the vertebrae should not be attempted without effective means to reduce the amplitude and variability of target motion because temporal dose variations owing to the intrafractional target motion can be significant.
PurposeTo provide a pilot dosimetric study of computed tomography (CT)-guided high-dose-rate (HDR) brachytherapy (BRT) and stereotactic body radiotherapy (SBRT) for primary and metastatic lung lesions.Material and methodsFor nine lung primary and metastasis patients, 3D image-based BRT plan using a single virtual catheter was planned for 34 Gy in single fraction to the gross tumor volume (GTV) + 3 mm margin to account for tumor deformation. These plans were compared to margin-based (MB-) and robustness optimized (RO-) SBRT, assuming the same tumor deformation under real-time tumor tracking. Consistent dose calculation was ensured for both BRT and SBRT plans using the same class of collapsed cone convolution superposition algorithm. Plan quality metrics were compared by Friedman tests and Wilcoxon t-tests.Results and ConclusionsBrachytherapy plans showed significant higher GTV mean dose compared to MB- and RO-SBRT (122.2 Gy vs. 50.4 and 44.7 Gy, p < 0.05), and better dose gradient index (R50) = 2.9 vs. 4.3 and 8.4 for MB- and RO-SBRT, respectively. Dose constraints per the RTOG 0915 protocol were achieved for all critical organs except chest wall in BRT. All other dose-volume histograms (DVH) metrics are comparable between BRT and SBRT. Treatment delivery time of BRT and SBRT plans significantly increased and decreased with increasing GTV size, respectively. SBRT using advanced MLC tracking technique and non-coplanar VMAT can achieve comparable dosimetric quality to HDR BRT. Whether or not, the significantly higher GTV dose can increase killing of radioresistant tumor cells and offset the effect of tumor reoxygenation in single fraction BRT, requires further clinical investigation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.