The DEAD box RNA helicase, p68, is upregulated in exponentially growing cells and shows cell cycledependent changes in nuclear localization. Although some other DEAD box proteins have been implicated in cancer, there have been no reports of any link between p68 status and carcinogenesis. In the present study we have analysed specimens from 50 patients with colorectal adenocarcinomas, including cases in which an adenomatous polyp was also present, by immunohistochemistry and Western blotting. Our data indicate that p68 protein is consistently overexpressed in tumours as compared with matched normal tissue. Examination of the levels of p68 mRNA from both normal and tumour tissue showed no obvious speci®c increase in p68 mRNA levels in tumours nor any evidence of underlying mutations in the p68 coding region. Interestingly, however, the accumulated p68 appears to be poly-ubiquitylated, suggesting a possible defect in proteasome-mediated degradation in these tumours. This overexpression/ubiquitylation is observed in both pre-invasive and invasive lesions suggesting that the dysregulation of p68 expression occurs early during tumour development. Finally, we demonstrate that ubiquitylation of p68 occurs in cultured cells, thereby providing a model for the molecular analysis of this process and its potential role in tumorigenesis. Oncogene (2001) 20, 7734 ± 7743.
Monosomy 1p36 is the most common terminal deletion syndrome seen in humans, occurring in approximately 1 in 5,000 live births. Common features include mental retardation, characteristic dysmorphic features, hypotonia, seizures, hearing loss, heart defects, cardiomyopathy, and behavior abnormalities. Similar phenotypes are seen among patients with a variety of deletion sizes, including terminal and interstitial deletions, complex rearrangements, and unbalanced translocations. Consequently, critical regions harboring causative genes for each of these features have been difficult to identify. Here we report on five individuals with 200-823 kb overlapping deletions of proximal 1p36.33, four of which are apparently de novo. They present with features of monosomy 1p36, including developmental delay and mental retardation, dysmorphic features, hypotonia, behavioral abnormalities including hyperphagia, and seizures. The smallest region of deletion overlap is 174 kb and contains five genes; these genes are likely candidates for some of the phenotypic features in monosomy 1p36. Other genes deleted in a subset of the patients likely play a contributory role in the phenotypes, including GABRD and seizures, PRKCZ and neurologic features, and SKI and dysmorphic and neurologic features. Characterization of small deletions is important for narrowing critical intervals and for the identification of causative or candidate genes for features of monosomy 1p36 syndrome.
IntroductionLong-term ventilated intensive care patients frequently require tracheostomy. Although overall risks are low, serious immediate and late complications still arise. Real-time ultrasound guidance has been proposed to decrease complications and improve the accuracy of the tracheal puncture. We aimed to compare the procedural safety and efficacy of real-time ultrasound guidance with the traditional landmark approach during percutaneous dilatational tracheostomy (PDT).MethodsA total of 50 patients undergoing PDT for clinical indications were randomly assigned, after obtaining informed consent, to have the tracheal puncture procedure carried out using either traditional anatomical landmarks or real-time ultrasound guidance. Puncture position was recorded via bronchoscopy. Blinded assessors determined in a standardised fashion the deviation of the puncture off midline and whether appropriate longitudinal position between the first and fourth tracheal rings was achieved. Procedural safety and efficacy data, including complications and number of puncture attempts required, were collected.ResultsIn total, 47 data sets were evaluable. Real-time ultrasound guidance resulted in significantly more accurate tracheal puncture. Mean deviation from midline was 15 ± 3° versus 35 ± 5° (P = 0.001). The proportion of appropriate punctures, defined a priori as 0 ± 30° from midline, was significantly higher: 20 (87%) of 23 versus 12 (50%) of 24 (RR = 1.74; 95% CI = 1.13 to 2.67; P = 0.006). First-pass success rate was 20 (87%) of 23 in the ultrasound group and 14 (58%) of 24 in the landmark group (RR = 1.49; 95% CI = 1.03 to 2.17; P = 0.028). The observed decrease in procedural complications was not statistically significant: 5 (22%) of 23 in the ultrasound group versus 9 (37%) of 24 in the landmark group (RR = 0.58; 95% CI = 0.23 to 1.47; P = 0.24).ConclusionsUltrasound guidance significantly improved the rate of first-pass puncture and puncture accuracy. Fewer procedural complications were observed; however, this did not reach statistical significance. These results support wider general use of real-time ultrasound guidance as an additional tool to improve PDT.Trial registrationAustralian New Zealand Clinical Trials Registry ID: ACTRN12611000237987 (registered 4 March 2011)Electronic supplementary materialThe online version of this article (doi:10.1186/s13054-014-0514-0) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.