In this paper, performing the thermal defectoscopy of a steel solid body by applying the thermovision camera, finite element method and method of filtering experimental data is proposed and implemented. Defect thickness, depth and size are analysed by defined temperature reference levels and simplified methodology. The thermal image processing is based on the proposed method. The applicability of this method can be confirmed by comparing analysis of obtained results with already known methods. The conducted experiment indicates that contactless method is efficient in the defects detection of thin non-complex prismatic parts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.