In patients with acute respiratory failure, noninvasive ventilation was as effective as conventional ventilation in improving gas exchange and was associated with fewer serious complications and shorter stays in the intensive care unit.
We applied near-infrared spectroscopy (NIRS) for the simultaneous measurement of forearm blood flow (FBF) and oxygen consumption (VO2) in the human by inducing a 50-mmHg venous occlusion. Eleven healthy subjects were studied both at rest and after hand exercise during vascular occlusion. FBF was also measured by strain-gauge plethysmography. FBF measured by NIRS was 1.9 +/- 0.8 ml.100 ml-1.min-1 at rest and 8.2 +/- 2.9 ml.100 ml-1.min-1 after hand exercise. These values showed a correlation (r = 0.94) with those obtained by the plethysmography. VO2 values were 4.6 +/- 1.3 microM O2 x 100 ml-1.min-1 at rest and 24.9 +/- 11.2 microM O2 x 100 ml-1.min-1 after hand exercise. The scatter of the FBF and VO2 values showed a good correlation between the two variables (r = 0.93). The results demonstrate that NIRS provides the particular advantage of obtaining the contemporary evaluation of blood flow and VO2, allowing correlation of these two variables by a single maneuver without discomfort for the subject.
This study reported on the application of near infrared spectroscopy (NIRS) to noninvasive measurements of forearm brachio-radial muscle oxygen consumption (VO2) and recovery time (tr) in untrained volunteers. Seven healthy subjects were submitted to four consecutive protocols involving measurements made at rest, the induction of an ischaemia, and during a maximal increase of metabolic demand achieved with and without vascular occlusion. Two isometric maximal voluntary contractions (MVC) of 30-s duration were executed with and without vascular occlusion and a 50% MVC lasting 125 s was also performed. The protocols were repeated on 2 different days. The results showed that, during vascular occlusion at rest, the time to 95% of the final haemoglobin (Hb) + myoglobin (Mb) desaturation value was independent of VO2. The MVC, performed during vascular occlusion, caused complete Hb+Mb desaturation in 15-20 s, which was not followed by any further desaturation when the second contraction was performed. No difference was found between VO2 during MVC with and without vascular occlusion. A consistent difference was seen between VO2 measured during occlusion at rest and VO2 measured during MVC with and without occlusion. During prolonged exercise (125 s) Hb+Mb desaturation was maintained for the whole contraction period. The results of this study show that VO2 can be measured noninvasively by NIRS. The VO2 during MVC was very similar both in the presence and absence of blood flow limitation in most of the subjects tested. This would suggest that muscle VO2 might be accurately evaluated dynamically without cuff occlusion.
These findings show that septic shock alters microvascular muscle function and regulation. Diminished local VO2 presumably reflects maldistribution and faulty autoregulation of local blood flow.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.