Nanoelectronic devices offer substantial potential for interrogating biological systems, although nearly all work has focused on planar device designs. We have overcome this limitation through synthetic integration of a nanoscale field effect transistor (nanoFET) device at the tip of an acute-angle kinked silicon nanowire, where nanoscale connections are made by the arms of the kinked nanostructure and remote multilayer interconnects allow three-dimensional (3D) probe presentation. The acute-angle probe geometry was designed and synthesized by controlling cis versus trans crystal conformations between adjacent kinks, and the nanoFET was localized through modulation doping. 3D nanoFET probes exhibited conductance and sensitivity in aqueous solution independent of large mechanical deflections, and demonstrated high pH sensitivity. Additionally, 3D nanoprobes modified with phospholipid bilayers can enter single cells to allow robust recording of intracellular potentials.
In the present study, we report the systematic investigation of the effect of chemical oxidation on the structure of single-walled carbon nanotubes (SWNTs) by using different oxidants. The oxidation procedure was characterized by using infrared spectroscopy and transmission electron microscopy (TEM). The SWNTs were produced by chemical vapor deposition (CVD) and oxidized with three kinds of oxidants: (1) nitric acid (2.6 M), (2) a mixture of concentrated sulfuric acid (98 wt %) and concentrated nitric acid (16 M) (v/v ) 3/1) and (3) KMnO 4 . The results reveal that the different functional groups can be introduced when the SWNTs are treated with different oxidants. Refluxing in dilute nitric acid can be considered as a mild oxidation for SWNTs, introducing the carboxylic acid groups only at those initial defects that already exist. The abundance of the carboxylic acid groups generated with this oxidant remained constant along with the treating time. In contrast, sonication of SWNTs in H 2 SO 4 /HNO 3 increased the incidence of carboxylic acid groups not only at initial defect sites but also at newly created defect sites along the walls of SWNTs. Compared to the two oxidants above, when KMnO 4 in alkali was used as the oxidant, which is relatively mild, different amounts of -OH, -CdO, and -COOH groups were introduced. The oxidation processes begin mainly with the oxidation of the initial defects that arise during the CVD growth of the SWNTs and are accompanied by processes that can be roughly divided into two steps: (1) the defect-generating step and (2) the defect-consuming step. Specifically, during the defect-generating step, the oxidants attack the graphene structure by electrophilic reactions and generate active sites such as -OH and -CdO. This step depends on the oxidant's ability to generate -C-OH groups and to transform them into -CdO groups. During the defect-consuming step, the graphene structure of the tube was destroyed by the oxidation of the generated active sites in step 1. The defect-consuming step mostly counts on the ability of the oxidant to etch/destroy the graphite-like structure around the already generated -CdO and their neighborhood groups.
The development of three-dimensional (3D) synthetic biomaterials as structural and bioactive scaffolds is central to fields ranging from cellular biophysics to regenerative medicine. As of yet, these scaffolds cannot electrically probe the physicochemical and biological micro-environments throughout their 3D and macroporous interior, although this capability could have a marked impact in both electronics and biomaterials. Here, we address this challenge using macroporous, flexible and free-standing nanowire nanoelectronic scaffolds (nanoES), and their hybrids with synthetic or natural biomaterials. 3D macroporous nanoES mimic the structure of natural tissue scaffolds, and they were formed by self-organization of coplanar reticular networks with built-in strain and by manipulation of 2D mesh matrices. NanoES exhibited robust electronic properties and have been used alone or combined with other biomaterials as biocompatible extracellular scaffolds for 3D culture of neurons, cardiomyocytes and smooth muscle cells. Additionally, we show the integrated sensory capability of the nanoES by real-time monitoring of (i) the local electrical activity within 3D nanoES/cardiomyocyte constructs, (ii) the response of 3D nanoES based neural and cardiac tissue models to drugs, and (iii) distinct pH changes inside and outside tubular vascular smooth muscle constructs.
The ability to make electrical measurements inside cells has led to many important advances in electrophysiology1-6. The patch clamp technique, in which a glass micropipette filled with electrolyte is inserted into a cell, offers both high signal-to-noise ratio and temporal resolution1,2. Ideally the micropipette should be as small as possible to increase the spatial resolution and reduce the invasiveness of the measurement, but the overall performance of the technique depends on the impedance of the interface between the micropipette and the cell interior1,2, which limits how small the micropipette can be. Techniques that involve inserting metal or carbon microelectrodes into cells are subject to similar constraints4,7-9. Field-effect transistors (FETs) can also record electric potentials inside cells10, and since their performance does not depend on impedance11,12, they can be made much smaller than micropipettes and microelectrodes. Moreover, FET arrays are better suited for multiplexed measurements. Previously we have demonstrated FET-based intracellular recording with kinked nanowire structures10, but the kink configuration and device design places limits on the probe size and the potential for multiplexing. Here we report a new approach where a SiO2 nanotube is synthetically integrated on top of a nanoscale FET. After penetrating the cell membrane, the SiO2 nanotube brings the cell cytosol into contact with the FET and enables the recording of intracellular transmembrane potential. Simulations show that the bandwidth of this branched intracellular nanotube FET (BIT-FET) is high enough for it to record fast action potentials even when the nanotube diameter is decreased to 3 nm, a length scale which is well below that accessible with other methods1,2,4. Studies of cardiomyocyte cells demonstrate that when brought close, the nanotubes of phospholipid-modified BIT-FETs spontaneously penetrate the cell membrane to yield stable, full-amplitude intracellular action potential recording, showing that a stable tight seal forms between the nanotube and cell membrane. We also show that multiple BIT-FETs can record multiplexed intracellular signals from both single cells and networks of cells.
Nanowire field-effect transistors (NW-FETs) have been shown to be powerful building blocks for nanoscale bioelectronic interfaces with cells and tissue due to their excellent sensitivity and their capability to form strongly coupled interfaces with cell membranes. Graphene has also been shown to be an attractive building block for nanoscale electronic devices, although little is known about its interfaces with cells and tissue. Here we report the first studies of graphene field effect transistors (Gra-FETs) as well as combined Gra-and NW-FETs interfaced to electrogenic cells. Gra-FET conductance signals recorded from spontaneously beating embryonic chicken cardiomyocytes yield well-defined extracellular signals with signal-to-noise ratio routinely >4. The conductance signal amplitude was tuned by varying the Gra-FET working region through changes in water gate potential, V wg . Signals recorded from cardiomyocytes for different V wg result in constant calibrated extracellular voltage, indicating a robust graphene/cell interface. Significantly, variations in V wg across the Dirac point demonstrate the expected signal polarity flip, thus allowing, for the first time, both n-and p-type recording to be achieved from the same Gra-FET simply by offsetting V wg . In addition, comparisons of peak-to-peak recorded signal widths made as a function of Gra-FET device sizes and versus NW-FETs allowed an assessment of relative resolution in extracellular recording. Specifically, peak-to-peak widths increased with the area of Gra-FET devices, indicating an averaged signal from different points across the outer membrane of the beating cells. One-dimensional silicon NW-FETs incorporated side by side with the two-dimensional Gra-FET devices further highlighted limits in both temporal resolution and multiplexed measurements from the same cell for the different types of devices. The distinct and complementary capabilities of Gra-and NW-FETs could open up unique opportunities in the field of bioelectronics in the future.Bioelectronic interfaces created with nanomaterials represents an exciting and growing field of research that exploits key nanomaterial properties to go well beyond the capabilities of conventional microfabricated electronics. 1-8 For example, several groups have recently reported electrical measurements from cells and tissue interfaced to NW-FETs, with results demonstrating high signal-to-noise recording from cultured neurons, muscle cells, embryonic chicken hearts and acute brain slices. [4][5][6][7][8] Unique features of these studies compared to conventional planar devices measurements, include (i) the exceptional small active area of the NW-FET devices and (ii) the fact that nanodevices protrude from the plane of the substrate. The former feature enables high spatial resolution, while the latter can increase device/cell interfacial coupling. Indeed, studies have shown that nanostructured interfaces can enhance cellular adhesion and activity, 9-14 and thus it is likely that NWs and other nanomaterials may...
Nanopores could potentially be used to perform single molecule DNA sequencing at low cost and with high throughput1–4. Although single-base resolution and differentiation have been demonstrated with nanopores using ionic current measurements5–7, direct sequencing has not been achieved due to difficulties in recording very small (~pA) ionic current at a bandwidth consistent with fast translocation speeds1–3. Here we show that solid-state nanopores can be combined with silicon nanowire field-effect transistors (FETs) to create sensors in which detection is localised and self-aligned at the nanopore. Well-defined FET signals associated with DNA translocation are recorded when an ionic strength gradient is imposed across the nanopores. Measurements and modelling show that FET signals are generated by highly-localized changes in the electrical potential during DNA translocation and that the nanowire-nanopore sensors could enable large-scale integration with a high intrinsic bandwidth.
Recording intracellular bioelectrical signals is central to understanding the fundamental behaviour of cells and cell-networks in, for example, neural and cardiac systems1–4. The standard tool for intracellular recording, the patch-clamp micropipette5 is widely applied, yet remains limited in terms of reducing the tip size, the ability to reuse the pipette5, and ion exchange with the cytoplasm6. Recent efforts have been directed towards developing new chip-based tools1–4,7–13, including micro-to-nanoscale metal pillars7–9, transistor-based kinked nanowire10,11 and nanotube devices12,13. These nanoscale tools are interesting with respect to chip-based multiplexing, but, to date, preclude targeted recording from specific cell regions and/or subcellular structures. Here we overcome this limitation in a general manner by fabricating free-standing probes where a kinked silicon nanowire with encoded field-effect transistor detector serves as the tip end. These probes can be manipulated in three dimensions (3D) within a standard microscope to target specific cells/cell regions, and record stable full-amplitude intracellular action potentials from different targeted cells without the need to clean or change the tip. Simultaneous measurements from the same cell made with free-standing nanowire and patch-clamp probes show that the same action potential amplitude and temporal properties are recorded without corrections to the raw nanowire signal. In addition, we demonstrate real-time monitoring of changes in the action potential as different ion-channel blockers are applied to cells, and multiplexed recording from cells by independent manipulation of two free-standing nanowire probes.
We have studied the electron transport behavior of electrochemically gated graphene transistors in different solutions. In an ionic liquid, we have determined the electron and hole carrier densities and estimated the concentration of charged impurities to be (1-10) x 10(12) cm(-2). The minimum conductivity displays an exponential decrease with the density of charged impurities, which is attributed to the impurity scattering of the carriers. In aqueous solutions, the position of minimum conductivity shifts negatively as the ionic concentration increases. The dependence of the transport properties on ionic concentration is important for biosensor applications, and the observation is modeled in terms of screening for impurity charges by the ions in solutions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.