To quantitatively analyze changes in the inner components of the human crystalline lens during accommodation in adults. Eyes of 23 subjects were sequentially examined using CASIA2 Optical Coherence Tomography under 0D, − 3D and − 6D accommodation states. The anterior chamber depth (ACD), anterior and posterior crystalline lens radius of the curvature (ALRC and PLRC) were obtained using built-in software. The lens thickness (LT), lenticular nucleus thickness (NT), anterior cortex thickness (ACT), posterior cortex thickness (PCT), anterior and posterior lenticular nucleus radius of the curvature (ANRC and PNRC), anterior and posterior lenticular nucleus vertex (ANV and PNV) were quantified manually with the Image-pro plus software. During accommodation, the ACD became significantly shallower and LT significantly increased. For changes in the lens, the ALRC decreased by an average magnitude (related to accommodative stimuli) 0.44 mm/D, and PLRC decreased 0.09 mm/D. There was no difference for the ACT and PCT in different accommodation states. For lenticular nucleus response, NT increased on average by 30 μm/D. Both the ANRC and PNRC decreased on average by 212 μm/D and 115 μm/D respectively. The ANV moved forward on average by 0.07 mm under − 3D accommodative stimuli and 0.16 mm for − 6D. However, there was no statistically significant difference between different accommodation states in the PNV movement. Under accommodation stimulation, lens thickness changed mainly due to the lenticular nucleus, but not the cortex. For the lenticular nucleus, both the ANRC and PNRC decreased and ANRC changed the most. The anterior surface of the nucleus moved forward while the posterior surface of the nucleus moved backward but only slightly.
Background: The Valsalva maneuver (VM) is widely used in daily life, and has been reported to cause high intraocular pressure (IOP). This study aimed to assess changes in IOP, the Schlemm's canal (SC), autonomic nervous system activity, and iridocorneal angle morphology in healthy individuals during different phases of the VM. Methods: The high frequency (HF) of heart rate (HR) variability, the ratio of low frequency power (LF) and HF (LF/HF), heart rate (HR), IOP, systolic (SBP) and diastolic blood pressure (DBP), the area of SC (SCAR), pupil diameter (PD), and some iridocorneal angle parameters (AOD500, ARA750, TIA500 and TISA500) were measured in 29 young healthy individuals at baseline, phase 2, and phase 4 of the VM. SBP and DBP were measured to calculate mean arterial pressure (MAP) and mean ocular perfusion pressure (MOPP). HF and the LF/HF ratio were recorded using Kubios HR variability premium software to evaluate autonomic nervous system activity. The profiles of the anterior chamber were captured by a Spectralis optical coherence tomography device (anterior segment module). Results: Compared with baseline values, in phase 2 of the VM, HR, LF/HF, IOP (15.1 ± 2.7 vs. 18.8 ± 3.5 mmHg, P < 0.001), SCAR (mean) (7712.112 ± 2992.14 vs. 8921.12 ± 4482.79 μm 2 , P = 0.039), and PD increased significantly, whereas MOPP, AOD500, TIA500, and TISA500 decreased significantly. In phase 4, DBP, MAP, AOD500, ARA750, TIA500and TISA500 were significantly lower than baseline value, while PD and HF were remarkably larger than baseline. The comparison between phase 2 and phase 4 showed that HR, IOP (18.8 ± 3.5 vs. 14.7 ± 2.9 mmHg, P < 0.001) and PD decreased significantly from phase 2 to phase 4, but there were no significant differences in other parameters. Conclusions: The expansion and collapse of the SC in different phases of the VM may arise from changes in autonomic nervous system activity. Further, the effects of the VM on IOP may be attributed to changes in blood flow and ocular anatomy. Trial registration: This observational study was approved by the ethics committee of Tongji Hospital (Registration Number: ChiCTR-OON-16007850, Date: 01.28.2016).
Purpose To estimate the outflow facility coefficient (C) as a function of Schlemm's canal cross-sectional area (SCAR) in healthy subjects using noninvasive oculopression tonometry (OPT). Methods In 25 healthy volunteers, intraocular pressure (IOP) decay values were recorded by a ophthalmodynamometer, with a fixed external force (0.15 N) on the inferior-temporal eyelid, every 10 seconds, for four minutes, and again after a 30-minute rest. Schlemm's canal profile images and IOP were obtained pre-procedurally (baseline), immediately (T0), and at 1-minute intervals post-procedurally (T1, T2, T3, and T4). C was calculated for different IOPs. The SCAR, coronal, and the meridional diameter of Schlemm's canal were calculated. Results Mean C 0 for the maximum IOP was 0.020 ± 0.017 µL/min/mm Hg; mean C was 0.018 ± 0.0071 and 0.058 ± 0.0146 µL/min/mm Hg at 40 and 20 mm Hg, respectively. C was nonlinearly dependent on the IOP ( R 2 = 0.945). The SCAR was 5440 ± 3140.82, 3947.6 ± 2246.8, and 5375.7 ± 2662.7 µm 2 at baseline, T0, and T4, respectively. The coronal diameter of SC decreased significantly from the baseline (33.02 ± 11.3 µm) to T0 (26.6 ± 9.37 µm) and recovered at T4 (32.3 ± 9.53 µm). The SCAR and IOP correlated significantly throughout ( R 2 = 0.9944; P < 0.001). C0 significantly correlated with the SCAR at baseline and with changes in the SCAR and IOP from T0 to T4. Conclusions Schlemm's canal dimensions are responsible for the IOP-dependent mechanical forces, and these changes appear to directly affect outflow facility.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.