Purpose: To describe the incidence and management of gastrointestinal tract Buckyball magnets ingestions in a multicenter Chinese pediatric patient population, and discuss the preventive measures. Methods: Medical records of 74 pediatric patients from 9 large Chinese hospitals during the past 10 years, who were diagnosed as buckyball magnets ingestion and got invasive treatment, were retrospectively studied. The follow-up was through telephone and outpatient service to estimate the post-surgery condition. Information collection was through online questionnaire. Results: Among the 74 cases, there were 50 boys (68%) and 24 girls (32%). The median age was 36 (interquartile range (IQR) 22-77) months, with a range of 7 months to 11 years, and it showed two peaks, the first between 1 and 3 years, and the second between 6 to 11 years. The annual case number showed a sharp increase over time, and the total case number in the last 2 years (2017 and 2018) showed a greater than 9-fold increase when compared with the first 2 years (2013 and 2014). The majority of ingestions were unintentional, with only 3 patients deliberately swallowing the Buckyball magnets. The median time of ingestion until the onset of emergent symptoms was 2 (IQR 1-5) days, and ranged from 4 h to 40 days. Twenty-one patients had no symptoms, and the remaining cases presented with abdominal pain, vomiting, fever, abdominal distension, excessive crying, melena, and the ceasing of flatus and defecation. Gastroscopy, colonoscopy, laparoscopic surgery and laparotomy surgery were performed in accordance with the algorithm from the North American Society of Pediatric Gastroenterology, Hepatology and Nutrition (NASPGHAN). Procedural and operative findings included gastrointestinal mucosa erosion, ischemia and necrosis, perforation, and abdominal abscess, fistula and intestinal obstruction. The median number of Buckyball magnets ingested was 4 (IQR 2-8), with a range from 1 to 39. During the median follow-up period of 6 (IQR 1-15) months, 3 patients had intestinal obstruction, and one underwent a second operation. The remaining 71 patients courses were uneventful during the follow-up period. None of the 74 patients reported a second swallowing of foreign bodies. Conclusions: The incidence of pediatric gastrointestinal tract magnets ingestion in China is increasing. Management of such patients should follow the NASPGHAN algorithm. Preventive measures to limit children's access to Buckyball magnets should be taken from three levels, namely the national administration, producer, and consumer.
Purpose: To describe the incidence and management of gastrointestinal tract Buckyball magnets ingestions in a multicenter Chinese pediatric patient population, and discuss the preventive measures. Methods: Medical records of 74 pediatric patients from 9 large Chinese hospitals during the past 10 years, who were diagnosed as buckyball magnets ingestion and got invasive treatment, were retrospectively studied. The follow-up was through telephone and outpatient service to estimate the post-surgery condition. Information collection was through online questionnaire. Results: Among the 74 cases, there were 50 boys (68%) and 24 girls (32%). The median age was 36 (interquartile range (IQR) 22-77) months, and it showed two peaks, the first between 1 and 3 years, and the second between 6 to 11 years. The annual case number showed a sharp increase over time, and the total case number in the last 2 years showed a greater than 9-fold increase when compared with the first 2 years. The majority of ingestions were unintentional, with only 3 patients deliberately swallowing the Buckyball magnets. The median time of ingestion until the onset of emergent symptoms was 2 (IQR 1-5) days. Twenty-one patients had no symptoms, and the remaining cases presented with abdominal pain, vomiting, fever, abdominal distension, excessive crying, melena, and the ceasing of flatus and defecation. Gastroscopy, colonoscopy, laparoscopic surgery and laparotomy surgery were performed in accordance with the algorithm from the North American Society of Pediatric Gastroenterology, Hepatology and Nutrition. Procedural and operative findings included gastrointestinal mucosa erosion, ischemia and necrosis, perforation, and abdominal abscess, fistula and intestinal obstruction. The median number of Buckyball magnets ingested was 4 (IQR 2-8). During the median follow-up period of 6 (IQR 1-15) months, 3 patients had intestinal obstruction, and one underwent a second operation. The remaining 71 patients were uneventful during the follow-up period. Conclusions: The incidence of pediatric gastrointestinal tract magnets ingestion in China is increasing. Management of such patients should follow the NASPGHAN algorithm. Preventive measures to limit children’s access to Buckyball magnets should be taken from three levels, namely the national administration, producer, and consumer. Keywords: Pediatric, Gastrointestinal tract, Magnetic foreign body, Buckyball
Intraoperative frozen pathological examination can well determine whether ectopic Meckel's diverticulum mucosa locates at the basal part. Basal ligation is a safe and effective operation method, and it can significantly shorten the operation time and postoperative fasting time.
BACKGROUND Inguinal hernia is a common clinical manifestation in children with a low self-healing rate. AIM To determine the effect of laparoscopic surgery on indirect inguinal hernia and the risk factors for postoperative recurrence and to provide a reference for the clinical treatment and prevention of recurrence. METHODS We selected 360 children who underwent laparoscopic high ligation in our hospital as the laparoscopic group and 120 patients treated for inguinal hernia with conventional surgery as the control group. The operation time, blood loss, incision length, hospitalization time, total hospitalization cost and surgical complications were compared between the two groups. According to telephone follow-up or return visits, the children who had recurrence within 2 years after the operation in the laparoscopic group were analyzed, and the laparoscopic high ligation hernia sac level was analyzed by the logistic multifactor method. Ligation was used to treat recurrence in children with inguinal hernia. RESULTS The operation time, blood loss, length of incision, and length of hospital stay in the laparoscopic group were lower than those in the control group ( P < 0.05). The total hospitalization cost in the laparoscopic group was higher than that in the control group ( P < 0.05). The operative complication rate was 1.67% lower than that in the control group (12.50%) ( P < 0.05). In 360 children with laparoscopic high ligation of the hernia sac, 14 patients had recurrence within 2 years after surgery. After analysis, 14 cases in the recurrence group did not recur. The preoperative incarceration rate, inner ring diameter, ligature use and age difference were statistically significant ( P < 0.05). According to logistic regression multivariate analysis, an inner ring diameter ≥ 1.0 cm, the use of an absorbable ligature line and age > 3 years increased the risk of postoperative recurrence in children with inguinal hernia after laparoscopic high ligation of the hernia sac ( P < 0.05). CONCLUSION Laparoscopic surgery for indirect inguinal hernia in children has the advantages of low trauma and a rapid postoperative recovery. An inner ring diameter ≥ 1.0 cm, the use of absorbable ligature, and age > 3 years may increase the risk of recurrence after laparoscopic high ligation of the hernia sac.
Purpose: To describe the incidence and management of gastrointestinal tract Buckyball magnets ingestions in a multicenter Chinese pediatric patient population, and discuss the preventive measures. Methods: Medical records of 74 pediatric patients from 9 large Chinese hospitals during the past 10 years, who were diagnosed as buckyball magnets ingestion and got invasive treatment, were retrospectively studied. The follow-up was through telephone and outpatient service to estimate the post-surgery condition. Information collection was through online questionnaire. Results: Among the 74 cases, there were 50 boys (68%) and 24 girls (32%). The median age was 36 (interquartile range (IQR) 22-77) months, with a range of 7 months to 11 years, and it showed two peaks, the first between 1 and 3 years, and the second between 6 to 11 years. The annual case number showed a sharp increase over time, and the majority of ingestions were unintentional. The median time of ingestion until the onset of emergent symptoms was 2 (IQR 1-5) days, and ranged from 4 hours to 40 days. Twenty-one patients had no symptoms, and the remaining cases presented with abdominal pain, vomiting, fever, abdominal distension, excessive crying, melena, and the ceasing of flatus and defecation. Gastroscopy, colonoscopy, laparoscopic surgery and laparotomy surgery were performed in accordance with the algorithm from the North American Society of Pediatric Gastroenterology, Hepatology and Nutrition (NASPGHAN). The median number of Buckyball magnets ingested was 4 (IQR 2-8), with a range from 1 to 39. During the median follow-up period of 6 (IQR 1-15) months, 3 patients had intestinal obstruction, and one underwent a second operation. The remaining 71 patients courses were uneventful during the follow-up period. None of the 74 patients reported a second swallowing of foreign bodies. Conclusions: The incidence of pediatric gastrointestinal tract magnets ingestion in China is increasing. Management of such patients should follow the NASPGHAN algorithm. Preventive measures to limit children’s access to Buckyball magnets should be taken from three levels, namely the national administration, producer, and consumer. Keywords: Pediatric, Gastrointestinal tract, Magnetic foreign body, Buckyball
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.