Real-time three-dimensional (3D) ultrasound (US) has attracted much more attention in medical researches because it provides interactive feedback to help clinicians acquire high-quality images as well as timely spatial information of the scanned area and hence is necessary in intraoperative ultrasound examinations. Plenty of publications have been declared to complete the real-time or near real-time visualization of 3D ultrasound using volumetric probes or the routinely used two-dimensional (2D) probes. So far, a review on how to design an interactive system with appropriate processing algorithms remains missing, resulting in the lack of systematic understanding of the relevant technology. In this article, previous and the latest work on designing a real-time or near real-time 3D ultrasound imaging system are reviewed. Specifically, the data acquisition techniques, reconstruction algorithms, volume rendering methods, and clinical applications are presented. Moreover, the advantages and disadvantages of state-of-the-art approaches are discussed in detail.
miRNAs (microRNAs) are frequently and aberrantly expressed in many cancers. MiR-873 has been revealed to be downregulated in colorectal cancer and glioblastoma. However, its function remains unclear. Here we report that miR-873 is downregulated in breast tumor compared with normal tissue. Enforced expression of miR-873 decreases the transcriptional activity of ER (estrogen receptor)-α but not ERβ through the modulation of ERα phosphorylation in ER-positive breast cancer cells. We also found that miR-873 inhibits breast cancer cell proliferation and tumor growth in nude mice. Reporter gene assays revealed cyclin-dependent kinase 3 (CDK3) as a direct target of miR-873. CDK3 was shown to be overexpressed in breast cancer and phosphorylate ERα at Ser104/116 and Ser118. Furthermore, we found that Mir-873 inhibits ER activity and cell growth via targeting CDK3. Interestingly, miR-873 was observed to be downregulated in tamoxifen-resistant MCF-7/TamR cells, while CDK3 is overexpressed in these cells. More importantly, re-expression of miR-873 reversed tamoxifen resistance in MCF-7/TamR cells. Our data demonstrate that miR-873 is a novel tumor suppressor in ER-positive breast cancer and a potential therapeutic approach for treatment of tamoxifen-resistant breast cancer.
1 Electromyography (EMG) has been widely used for the assessment of 2 musculoskeletal functions and the control of electrical prostheses, which make use of the 3 EMG signal generated by the contraction of the residual muscles. In spite of the successful 4 applications of EMG in different fields, it has some inherent limitations, such as the 5 difficulty to differentiate the actions of neighboring muscles and to collect signals from 6 deep muscles using the surface EMG. The majority of current EMG controlled prostheses 7 can only provide sequential on-off controls using signals from two groups of muscles, so 8 the users are required to put many conscious efforts in monitoring the speed and range of 9 motion of the terminal devices being controlled. Recently, many alternative signals based 10 on the detection of dimensional changes of muscles or tendons during actions have been 11 reported. The objective of this study was to investigate the potential of the dimensional 12 change of muscles detected using sonography for musculoskeletal assessment and control. 13 A portable B-mode ultrasound scanner was used to collect the dynamic ultrasound images 14 of the forearm muscles of six normally-limbed young adults and three amputee subjects. A 15 motion analysis system was used to collect the movement of the wrist angle during the 16 experiments for the normal subjects. It was demonstrated that the morphological changes of 17 forearm muscles during actions can be successfully detected by ultrasound and linearly 18 correlated (R 2 = 0.876±0.042, mean±SD) with the wrist angle. We named these 19 sonographically detected signals about the architectural change of the muscle as 20 sonomyography (SMG). The mean ratio between the wrist angle and the percentage 21 deformation of the forearm muscle was 7.2±3.7 deg/% for the normal subjects. The 22 intraclass correlation coefficient (ICC) of this ratio among the three repeated tests was 23 0.868. The SMG signals from the residual forearms were also successfully detected when 24 3 the three amputee subjects contracted their residual muscles. The results demonstrated that 1 SMG had potentials for the musculoskeletal control and assessment. 2 3 4
The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.
We have summarized and compared many techniques on BUS image segmentation and found that all these techniques have their own pros and cons. However, BUS image segmentation is still an open and challenging problem due to various ultrasound artifacts introduced in the process of imaging, including high speckle noise, low contrast, blurry boundaries, low signal-to-noise ratio and intensity inhomogeneity CONCLUSIONS: To the best of our knowledge, this is the first comprehensive review of the approaches developed for segmentation of BUS images. With most techniques involved, this paper will be useful and helpful for researchers working on segmentation of ultrasound images, and for BUS CAD system developers.
A novel noncontact indentation system with the combination of an air jet and optical coherence tomography (OCT) was presented in this paper for the quantitative measurement of the mechanical properties of soft tissues. The key idea of this method is to use a pressure-controlled air jet as an indenter to compress the soft tissue in a noncontact way and utilize the OCT signals to extract the deformation induced. This indentation system provides measurement and mapping of tissue elasticity for small specimens with high scanning speed. Experiments were performed on 27 silicone tissue-mimicking phantoms with different Young’s moduli, which were also measured by uniaxial compression tests. The regression coefficient of the indentation force to the indentation depth (N mm−1) was used as an indicator of the stiffness of tissue under air jet indentation. Results showed that the stiffness coefficients measured by the current system correlated well with the corresponding Young’s moduli obtained by conventional mechanical testing (r = 0.89, p < 0.001). Preliminary in vivo tests also showed that the change of soft tissue stiffness with and without the contraction of the underlying muscles in the hand could be differentiated by the current measurement. This system may have broad applications in tissue assessment and characterization where alterations of mechanical properties are involved, in particular with the potential of noncontact micro-indentation for tissues.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.