Proton exchange membrane fuel cell (PEMFC) generates a lot of heat during power generation. It is necessary to control PEMFC to operate at proper temperature through effective thermal management. CFD model of flow field plates with different structures is established; the heat transfer performance of different flow fields was analyzed by numerical simulation. The index of uniformity temperature (IUT) was introduced to further evaluate the heat transfer effect. The results showed that the parallel flow field was not suitable for cooling due to its poor performance at high coolant flow rate. The pressure difference of serpentine flow field was more than 10 times that of other flow fields, which lead to the highest cost in practical cooling application. The wave flow field with the best comprehensive cooling effect at high flow velocity, and the average temperature and IUT were 2.22% and 37.97% lower than the parallel flow field, respectively. The cooling effect of point flow field followed the second, and its average temperature and IUT were 1.65% and 29.71% lower than those of parallel flow field, respectively. In practice application, the wavy flow field showed better heat transfer performance within the required coolant flow range.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.