We have developed a new atomic force microscope with differential laser interferometers (DLI-AFM), carried out test measurements of the prototype 1D-grating standards with pitches of 100, 80, 60 and 50 nm using the DLI-AFM and evaluated the uncertainty in the pitch measurements. In the procedures of the pitch calculation, two types of definitions of the peak positions, ‘the centre of gravity method’, and ‘the zero-crossing method’, were compared. The zero-crossing method was adopted in this study since the standard deviation of pitches by the zero-crossing method was smaller than that by the centre of gravity method. The expanded uncertainty (k = 2) was approximately 0.20 nm and was only 0.4% for the nominal pitch of 50 nm. We propose a design of usable 1D-grating standards as certified reference materials.
This paper presents a new analogue contact probe based on a compact 3D optical sensor with high precision. The sensor comprises an autocollimator and a polarizing Michelson interferometer, which can detect two angles and one displacement of the plane mirror at the same time. In this probe system, a tungsten stylus with a ruby tip-ball is attached to a floating plate, which is supported by four V-shape leaf springs fixed to the outer case. When a contact force is applied to the tip, the leaf springs will experience elastic deformation and the plane mirror mounted on the floating plate will be displaced. The force-motion characteristics of this probe were investigated and optimum parameters were obtained with the constraint of allowable physical size of the probe. Simulation results show that the probe is uniform in 3D and its contacting force gradient is within 1 mN µm − 1. Experimental results indicate that the probe has 1 nm resolution, ± 10 µm measuring range in X − Y plane, 10 µm measuring range in Z direction and within 30 nm measuring standard deviation. The feasibility of the probe has been preliminarily verified by testing the flatness and step height of high precision gauge blocks.
Most homodyne interferometers have a quadrature detector system that includes two polarizing beam splitters that cause nonlinearity of the order of a few nanometers by phase mixing. Detectors should have the same gains to reduce nonlinearity under the assumption that there is no loss in optical components. However, optical components exhibit some loss. We show that nonlinearity can be reduced to an order of 0.01 nm when the detector gains are adjusted by simulation to include the optical characteristics. The compensated nonlinearity is 18 times smaller than that when the four detector gains are set to be equal.
Abstract:To measure various components with nano-scale precision, a new high-precision touch-trigger probe using a single low-cost sensor for a micro-coordinate measuring machine (CMM) is presented in this paper. The sensor is composed of a laser diode, a plane mirror, a focusing lens, and a quadrant photo detector (QPD). The laser beam from the laser diode with an incident angle is reflected by the plane mirror and then projected onto the quadrant photo detector (QPD) via the focusing lens. The plane mirror is adhered to the upper surface of the floating plate supported by an elastic mechanism, which can transfer the displacement of the stylus's ball tip in 3D to the plane mirror's vertical and tilt movement. Both motions of the plane mirror can be detected by respective QPDs. The probe mechanism was analyzed, and its structural parameters that conform to the principle of uniform sensitivity and uniform stiffness were obtained. The simulation result showed that the stiffness was equal in 3D and less than 1 mN/µm. Some experiments were performed to investigate the probe's characteristics. It was found that the probe could detect the trigger point with uniform sensitivity, a resolution of less than 5 nm, and a repeatability of less than 4 nm. It can be used as a touch-trigger probe on a micro/nano-CMM.
A new method to fabricate an integrated optical fiber micro-sphere with a diameter within 100 µm, based on the optical fiber tapering technique and the Taguchi method is proposed. Using a 125 µm diameter single-mode (SM) optical fiber, an optical fiber taper with a cone angle is formed with the tapering technique, and the fabrication optimization of a micro-sphere with a diameter of less than 100 µm is achieved using the Taguchi method. The optimum combination of process factors levels is obtained, and the signal-to-noise ratio (SNR) of three quality evaluation parameters and the significance of each process factors influencing them are selected as the two standards. Using the minimum zone method (MZM) to evaluate the quality of the fabricated optical fiber micro-sphere, a three-dimensional (3D) numerical fitting image of its surface profile and the true sphericity are subsequently realized. From the results, an optical fiber micro-sphere with a two-dimensional (2D) diameter less than 80 µm, 2D roundness error less than 0.70 µm, 2D offset distance between the micro-sphere center and the fiber stylus central line less than 0.65 µm, and true sphericity of about 0.5 µm, is fabricated.
Abstract:A micro Coordinate Measuring Machine (CMM) with the measurement volume of 50 mmˆ50 mmˆ50 mm and measuring accuracy of about 100 nm (2σ) has been developed. In this new micro CMM, an XYZ stage, which is driven by three piezo-motors in X, Y and Z directions, can achieve the drive resolution of about 1 nm and the stroke of more than 50 mm. In order to reduce the crosstalk among X-, Y-and Z-stages, a special mechanical structure, which is called co-planar stage, is introduced. The movement of the stage in each direction is detected by a laser interferometer. A contact type of probe is adopted for measurement. The center of the probe ball coincides with the intersection point of the measuring axes of the three laser interferometers. Therefore, the metrological system of the CMM obeys the Abbe principle in three directions and is free from Abbe error. The CMM is placed in an anti-vibration and thermostatic chamber for avoiding the influence of vibration and temperature fluctuation. A series of experimental results show that the measurement uncertainty within 40 mm among X, Y and Z directions is about 100 nm (2σ). The flatness of measuring face of the gauge block is also measured and verified the performance of the developed micro CMM.
To achieve true 3D nano-measurement with sub-nanometer resolution and very low touch force through a micro/nano coordinate measuring machine, a new 3D resonant trigger probe based on a quartz tuning fork is proposed. In this trigger probe, a quartz tuning fork with a microsphere tip vibrates at its resonant frequency, and is used as the sensing element. The resonance parameters of this quartz tuning fork (e.g., vibrating amplitude and resonant frequency) are extremely sensitive to external 3D microforces. The distinguished feature of this probe is its ability to interact with the sample surface in the actual three directions. The microsphere tip of the probe interacts with the sample surface in tapping mode in the Z direction, whereas it interacts in friction mode in the X and Y directions. The dynamic contact mechanism of the probe is based on interfacial force theory, and mechanical models of the interactions between the microsphere tip and sample surface in the X, Y, and Z directions are constructed and simulated. The experiment shows that the probe has sub-nanometer resolution in 3D directions and triggers repeatability of approximately 40 nm in each direction. Theoretical analysis and experimental results verify that this 3D resonant trigger probe can be used for true 3D profile measurement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.