Little is known about central neuron mechanosensation. Gu et al. report that micromechanical stress preferentially induces rapid and reversible varicosity formation in the axons but not the dendrites of hippocampal neurons through activation of mechanosensitive ion channels and microtubule disassembly.
A quasi-linear viscoelasticity (QLV) model was used to study passive time-dependent responses of skeletal muscle to repeated massage-like compressive loading (MLL) following damaging eccentric exercise. Six skeletally mature rabbits were surgically instrumented with bilateral peroneal nerve cuffs for stimulation of the hindlimb tibialis anterior (TA) muscles. Following the eccentric exercise, rabbits were randomly assigned to a four-day MLL protocol mimicking deep effleurage (0.5 Hz, 10 N for 15 min or for 30 min). The contralateral hindlimb served as the exercised, no-MLL control for both MLL conditions. Viscoelastic properties of the muscle pre-exercise, post-exercise on Day 1, and pre- and post-MLL Day 1 through Day 4 were determined with ramp-and-hold tests. The instantaneous elastic response (AG0) increased following exercise (p <0.05) and decreased due to both the 15 min and 30 min four-day MLL protocols (p<0.05). Post-four days of MLL the normalized AG0 decreased from post-exercise (Day 1, 248.5%) to the post-MLL (Day 4, 98.5%) (p<0.05), compared to the no-MLL group (Day 4, 222.0%) (p<0.05). Exercise and four-day MLL showed no acute or cumulative effects on the fast and slow relaxation coefficients (p>0.05). This is the first experimental evidence of the effect of both acute (daily) and cumulative changes in viscoelastic properties of intensely exercised muscle due to ex vivo MLL. It provides a starting point for correlating passive muscle properties with mechanical effects of manual therapies, and may shed light on design and optimization of massage protocols.
Fluid shear stress (FSS) plays a critical role in regulating endothelium function and maintaining vascular homeostasis. Current microfluidic devices for studying FSS effects on cells either separate high shear stress zone and low shear stress zone into different culturing chambers, or arranging the zones serially along the flow direction, which complicates subsequent data interpretation. In this paper, we report a diamond shaped microfluidic shear device where the high shear stress zone and the low shear stress zone are arranged in parallel within one culturing chamber. Since the zones with different shear stress magnitudes are aligned normal to the flow direction, the cells in one stress group are not substantially affected by the flow-induced cytokine/chemokine releases by cells in the other group. Cell loading experiments using human umbilical vein endothelial cells show that the device is able to reveal stress magnitude-dependent and loading duration-dependent cell responses. The co-existence of shear stress zones with varied magnitudes within the same culturing chamber not only ensures that all the cells are subject to the identical culturing conditions, but also allows the resemblance of the differential shear stress pattern in natural arterial conditions. The device is expected to provide a new solution for studying the effects of heterogeneous hemodynamic patterns in the onset and progression of various vascular diseases. V C 2014 AIP Publishing LLC.
Massage therapy has a long history and has been widely believed effective in restoring tissue function, relieving pain and stress, and promoting overall well-being. However, the application of massage-like actions and the efficacy of massage are largely based on anecdotal experiences that are difficult to define and measure. This leads to a somewhat limited evidence-based interface of massage therapy with modern medicine. In this study, we introduce a mechatronic device that delivers highly reproducible massage-like mechanical loads to the hind limbs of small animals (rats and rabbits), where various massage-like actions are quantified by the loading parameters (magnitude, frequency and duration) of the compressive and transverse forces on the subject tissues. The effect of massage is measured by the difference in passive viscoelastic properties of the subject tissues before and after mechanical loading, both obtained by the same device. Results show that this device is useful in identifying the loading parameters that are most conducive to a change in tissue mechanical properties, and can determine the range of loading parameters that result in sustained changes in tissue mechanical properties and function. This device presents the first step in our effort for quantifying the application of massage-like actions used clinically and measurement of their efficacy that can readily be combined with various quantitative measures (e.g., active mechanical properties and physiological assays) for determining the therapeutic and mechanistic effects of massage therapies.
Liquid lens offers a simple solution to achieve tunable optical powers. This approach, however, suffers from deteriorated resolution at high diopters. In this study, a plano-convex liquid lens with aspherical cross-section is developed. Such configuration allows for the lens profiles at high diopters to be close to spherical shapes by alleviating the edge-clamping effects. Resolution tests of a 6mm lens with optimized asphericity exhibit improved resolutions in both center and peripheral regions at 40 and 100 diopters than the lenses with planar membranes. It shows that aspherical membranes can improve the resolving power of liquid lenses at high diopters, thus providing a new route of optimizing the imaging performance of adaptive liquid lenses for various applications.
Mechanical stimuli regulate cell structure and function during physiological processes. To understand the role of mechanical stimuli, engineered devices are developed to deliver controllable mechanical signals to cells cultured in vitro. Localized mechanical loading on selected cells are preferred when investigating intercellular communication. In this work, we fabricated and characterized a polydimethylsiloxane (PDMS) micro-device for applying controlled compressive/tensile loads to selected live cells. The device consists of nine circular PDMS membranes serving as the loading sites; the loading parameters at each site are individually controllable. The in-plane strain upon PDMS membrane deflection was experimentally characterized. The result showed that for a circular membrane with 500 µm in diameter and 60 µm thick, the radial strain from −6% (compressive) to 25% (tensile) can be achieved at the membrane center. This device allows localized cell loading with minimal fabrication/operation complexity and ease of scaling-up. It is expected to foster the development of high throughput mechanical loading systems for a broad array of cellular mechanobiological studies.
Background This study compared immediate versus delayed massage-like compressive loading on skeletal muscle viscoelastic properties following eccentric exercise. Methods Eighteen rabbits were surgically instrumented with peroneal nerve cuffs for stimulation of the tibialis anterior muscle. Rabbits were randomly assigned to a massage loading protocol applied immediately post exercise (n=6), commencing 48 hours post exercise (n=6), or exercised no-massage control (n=6). Viscoelastic properties were evaluated in vivo by performing a stress-relaxation test pre- and post-exercise and daily pre- and post-massage for four consecutive days of massage loading. A quasi-linear viscoelastic approach modeled the instantaneous elastic response (AG0), fast ( g1p) and slow ( g2p) relaxation coefficients, and the corresponding relaxation time constants τ1 and τ2. Findings Exercise increased AG0 in all groups (P<0.05). After adjusting for the three multiple comparisons, recovery of AG0 was not significant in the immediate (P=0.021) or delayed (P=0.048) groups compared to the control group following four days of massage. However, within-day (pre- to post-massage) analysis revealed a decrease in AG0 in both massage groups. Following exercise, g1p increased and g2p and τ1 decreased for all groups (P<0.05). Exercise had no effect on τ2 (P>0.05). After four days of massage, there was no significant recovery of the relaxation parameters for either massage loading group compared to the control group. Interpretation Our findings suggest that massage loading following eccentric exercise has a greater effect on reducing muscle stiffness, estimated by AG0, within-day rather than affecting recovery over multiple days. Massage loading also has little effect on the relaxation response.
Mechanical stretching and topographical cues are both effective mechanical stimulations for regulating cell morphology, orientation, and behaviors. The competition of these two mechanical stimulations remains largely underexplored. Previous studies have suggested that a small cyclic mechanical strain is not able to reorient cells that have been pre-aligned by relatively large linear microstructures, but can reorient those pre-aligned by small linear micro/nanostructures if the characteristic dimension of these structures is below a certain threshold. Likewise, for micro/nanostructures with a given characteristic dimension, the strain must exceed a certain magnitude to overrule the topographic cues. There are however no in-depth investigations of such "thresholds" due to the lack of close examination of dynamic cell orientation during and shortly after the mechanical loading. In this study, the time-dependent combinatory effects of active and passive mechanical stimulations on cell orientation are investigated by developing a micromechanical stimulator. The results show that the cells pre-aligned by linear micro/nanostructures can be altered by cyclic in-plane strain, regardless of the structure size. During the loading, the micro/nanostructures can resist the reorientation effects by cyclic in-plane strain while the resistive capability (measured by the mean orientation angle change and the reorientation speed) increases with the increasing characteristic dimension. The micro/nanostructures also can recover the cell orientation after the cessation of cyclic in-plane strain, while the recovering capability increases with the characteristic dimension. The previously observed thresholds are largely dependent on the observation time points. In order to accurately evaluate the combinatory effects of the two mechanical stimulations, observations during the active loading with a short time interval or endpoint observations shortly after the loading are preferred. This study provides a microengineering solution to investigate the time-dependent combinatory effects of the active and passive mechanical stimulations and is expected to enhance our understanding of cell responses to complex mechanical environments. Biotechnol. Bioeng. 2016;113: 2191-2201. © 2016 Wiley Periodicals, Inc.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.