A simple, cost-effective, sensitive, and quick method for the determination of nitenpyram and its metabolite 6-chloronicotinic acid in environmental samples was developed by coupling an ion chromatograph with a fluorescence detector and a post-column photochemical reactor. This developed analytical method involved a rapid sample extraction by modified and miniaturized quick, easy, cheap, effective, rugged, and safe method followed by isocratic ion chromatographic separation of nitenpyram and 6-chloronicotinic acid into an IonPac AS11-HC column protected by IonPac AG11A guard column by running 30 mM NaOH + 10% acetonitrile mobile phase. A homemade post-column photochemical reactor was also integrated with the ion chromatographic system for online transformation of both analytes into their respective highly fluorescent photoproduct in basic media without using an extra pump. The developed method was validated by following SANTE/11945/2015 guidelines on analytical quality control and validation procedures. The method showed a good linear response (r > 0.999), improved limit of detection (0.101-0.132 μg/L), minimum or no matrix effect, excellent recoveries (90.2-100.10%) and relative standard deviations were found to be ≤6.50%.
A 2D-IC system was successfully fabricated for clean isocratic chromatographic separations and sensitive post column UV induced fluorescence determination of two NNIs in six complex food samples.
An end-to-end differential measurement approach with capacitively coupled contactless conductivity detection (C(4)D) was applied to anion-exchange monolithic capillary column ion chromatography. The column was prepared by thermally initiated radical polymerization of poly(glycidyl methacrylate) in a fused-silica capillary of 320 μm i.d. and modified by quaternary ammonium latex surface coating. Two C(4)Ds were placed near both ends of the capillary column and the output difference between them was measured. With 15 mM potassium hydrogen phthalate used as the eluent, good separation of a mixture of inorganic anions (F(-), Cl(-), NO(2)(-), NO(3)(-)) was achieved. The detection limits of conventional C(4)D are 1.6, 0.28, 0.53, and 0.47 mg L(-1) for F(-), Cl(-), NO(2)(-), and NO(3)(-), respectively. To further enhance the sensitivity, the capacitive impedance from C(4)D was neutralized by an inductive impedance from a piezoelectric resonator. An increase in sensitivity by a factor of 7-8 was achieved in the resonating C(4)D in comparison with the conventional C(4)D. The detection limits of the resonating C(4)D are 0.23, 0.041, 0.065, and 0.059 mg L(-1) for F(-), Cl(-), NO(2)(-), and NO(3)(-), respectively. The response of the resonating C(4)D was analyzed based on an equivalent circuit model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.