A commitment to condition monitoring involves the operators of plant in the conduct of a range of activities. These activities may be complicated in nature and indeed may often be performed automatically under computer control. They can, however, always be down into a relatively small number of easily identifiable functional tasks. This makes it much easier to identify the common elements of machine condition monitoring schemes. A proposed interface circuit design and application will be further explain in this paper, the implemented monitoring unit circuit also illustrated, see appendix A. Two scenarios presented in this paper, first ten turns assume to be shorted, and in the second thirty turns shorted to show the difference in the amplitude of frequencies at each case. This paper present. An improvement in three-phase squirrel-cage induction motor stator inter-turn fault detection and diagnosis based on a neural network approach is presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.